Parameters App - How To Guide

⚙️ Parameters App - Complete User Guide

🚀 Quick Start (5 Minutes)

New user? Start here! Follow these steps to create your first equipment configuration:

  1. Create Equipment Type: Parameters → Equipment Types → Add → "Variable Speed Drives"
  2. Add Manufacturer Model: Parameters → Manufacturer Models → Add → "Siemens SINAMICS G120"
  3. Create Device Setting: Parameters → Configurations → Add → "VFD-PMP-001"
  4. Configure Values: Click "Batch Edit Values" and fill in parameters

Done! You've configured your first device. Keep reading for advanced features.

1. Introduction

The Parameters App is a comprehensive industrial equipment parameter management system designed for engineers and project managers working with electrical and process control systems.

📁 Organize Equipment

Hierarchical equipment categories with unlimited nesting

🔧 Reusable Templates

Create parameter templates for manufacturer models

🏗️ Complex Assemblies

Build MCCs, panels, and control cabinets

✅ Validation

Built-in parameter validation with min/max/step rules

🌐 Collaboration

Share templates across your organization

📊 Import/Export

CSV and Excel import/export capabilities

Perfect for managing:

  • Variable Frequency Drives (VFDs)
  • Programmable Logic Controllers (PLCs)
  • Motor Protection Relays
  • Process Instrumentation (flow, pressure, level transmitters)
  • Any industrial equipment requiring systematic parameter configuration

2. Getting Started

Accessing the Dashboard

Navigate to /parameters/ to access your personal dashboard. The dashboard displays:

  • Statistics: Total assemblies, configurations, and templates
  • Recent Activity: Last 5 assemblies, configurations, and templates
  • Quick Actions: Create new items, manage templates

Understanding the Data Hierarchy

Equipment Type (e.g., "Variable Speed Drives")
  └─> Manufacturer Model (e.g., "Siemens SINAMICS G120")
       └─> Parameter Set (template with parameters)
            └─> Parameter Templates (e.g., "P0001: Motor Voltage")
                 └─> Parameter Options (e.g., "230V", "480V")

Device Group (e.g., "MCC-01")
  └─> Device Setting (e.g., "VFD-PMP-001")
       └─> Setting Values (actual configured values)

3. Core Features

Equipment Types

Creating Equipment Types

  1. Go to Parameters → Equipment Types → Add New
  2. Fill in the form:
    • Name: "Variable Speed Drives" (required)
    • Parent: Select parent category or leave blank
    • Description: Detailed description
    • Icon: CSS icon class (e.g., fas fa-cog)
    • Share: Check to make available to all users
  3. Click Save Equipment Type

Example Hierarchy:

Instruments
  ├─ Flow Meters
  │   ├─ Magnetic Flow Meters
  │   └─ Ultrasonic Flow Meters
  ├─ Pressure Transmitters
  └─ Level Transmitters
Variable Speed Drives
  ├─ Low Voltage VFDs
  └─ Medium Voltage VFDs
Protection Relays
  ├─ Motor Protection (50/51)
  ├─ Transformer Protection (87T)
  └─ Overcurrent (50/51)

Manufacturer Models & Parameter Sets

Creating Combined Manufacturer Model + Parameter Set

  1. Go to Parameters → Manufacturer Models → Add New
  2. Manufacturer Model Section:
    • Equipment Type: Select from dropdown
    • Manufacturer: "Siemens", "ABB", "Schneider Electric"
    • Model Number: "SINAMICS G120", "ACS880"
    • Firmware Version: Optional
    • Share: Check to share with all users
  3. Parameter Set Section:
    • Description: "Standard VFD parameters"
    • Version: "1.0"
    • Upload Equipment Manual (PDF)
    • Upload Device Photo
  4. Click Save

Device Groups (Equipment Assemblies)

Create hierarchical assemblies of equipment such as Motor Control Centers (MCCs), panels, and control cabinets.

Creating Device Groups

  1. Navigate to Parameters → Device Groups → Add New
  2. Fill in:
    • Name: "MCC-01" (required)
    • Tag Number: "MCC-E-01"
    • Parent: Select parent assembly (optional)
    • Description: "Main Motor Control Center - Area 1"
    • Location: "Electrical Room 101"
  3. Click Save Device Group

Example Assembly:

MCC-01 (Main Motor Control Center)
  ├─ MCC-01-Comp-01 (Compartment 1)
  │   ├─ VFD-PMP-001 (Cooling Water Pump VFD)
  │   └─ VFD-PMP-002 (Chilled Water Pump VFD)
  ├─ MCC-01-Comp-02 (Compartment 2)
  │   ├─ Relay-MOT-001 (Motor Protection Relay)
  │   └─ Relay-MOT-002 (Motor Protection Relay)
  └─ MCC-01-Comp-03 (Compartment 3)
      └─ PLC-001 (Control PLC)

Device Settings (Project Configurations)

Configure actual device instances with specific parameter values.

Creating Device Settings

  1. Navigate to Parameters → Device Settings → Add New
  2. Basic Information:
    • Name: "VFD-PMP-001"
    • Tag Number: "21-VFD-001"
    • Template: Select manufacturer model
    • Status: Draft / Review / Approved / Deployed / Archived
  3. Assembly Information:
    • Parent Assembly: Select device group
    • Position: "Slot 1", "Compartment A"
  4. Location & Service:
    • Location: "Pump Room 205"
    • Service: "Cooling Water Circulation Pump #1"
  5. Click Save
  6. Click Batch Edit Values to configure parameters

💡 Status Workflow

DRAFT → REVIEW → APPROVED → DEPLOYED → ARCHIVED

  • Draft: Initial configuration, editable
  • Review: Submitted for engineering review
  • Approved: Reviewed and approved for deployment
  • Deployed: Actively used in the field
  • Archived: Decommissioned or replaced

Parameter Templates

Define reusable parameter definitions with validation rules.

Parameter Field Types

TypeDescriptionExample
TXTText stringDevice name, IP address
INTInteger numberCommunication address, count
FLTFloating-point numberVoltage, current, frequency
BOOBooleanEnable/disable, on/off
SELSingle selectionCommunication protocol
MULMultiple selectionEnabled features

Parameter Categories

  • PROT: Protection settings
  • CTRL: Control parameters
  • MEAS: Measurement settings
  • COMM: Communication configuration
  • DIAG: Diagnostics settings
  • CONF: General configuration

4. Complete Workflows

Workflow 1: Setting Up a VFD from Scratch

Scenario: Configure a Siemens G120 VFD for a cooling water pump.

  1. Create Equipment Type: "Variable Speed Drives"
  2. Create Manufacturer Model: "Siemens SINAMICS G120" with parameter set
  3. Create Device Group: "MCC-01" in Electrical Room 101
  4. Create Device Setting: "VFD-PMP-001" using G120 template
  5. Configure Parameters:
    • P0001 (Motor Voltage): 480V
    • P0002 (Motor Current): 52A
    • P0003 (Motor Frequency): 60Hz
    • P1000 (Frequency Set Point): 60Hz
    • P1120 (Min Frequency): 30Hz
  6. Review & Approve: Change status to "Approved", then "Deployed"

Workflow 2: Building an MCC with Multiple Devices

Scenario: Configure a 10-compartment motor control center.

  1. Create Main Assembly: "MCC-E-01" in Electrical Room 101
  2. Create Sub-Assemblies: MCC-E-01-Comp-01 through Comp-10
  3. Add Devices:
    • Comp-01: VFD-PMP-001 (480V, 50HP)
    • Comp-02: VFD-PMP-002 (480V, 50HP)
    • Comp-03: VFD-FAN-001 (480V, 25HP)
    • Comp-04-10: Motor starters, protection relays
  4. Configure All Parameters: Use batch edit for each device
  5. Export Configuration: Export to Excel for documentation

5. CSV Import/Export

Importing Parameter Templates

  1. Download Template: Dashboard → "Download Parameter Template CSV"
  2. Fill in Excel:
    name,code,description,category,field_type,unit,min_value,max_value,...
    Motor Rated Voltage,P0001,Rated voltage of motor,CONF,FLT,V,0,1000,...
    Motor Rated Current,P0002,Rated current of motor,CONF,FLT,A,0,1000,...
  3. Upload: Dashboard → "Upload Parameter Templates"
  4. Review Results: Check success/error messages

Exporting Equipment Types to Excel

  1. Navigate to Parameters → Equipment Types → Tree View
  2. Click Export to Excel
  3. Excel file includes: ID, Name, Description, Icon, Is Shared, Parent
  4. Edit offline and re-import if needed

6. Tree View Management

Tree views provide visual hierarchy management for Equipment Types and Device Groups.

Features

  • Visual Hierarchy: See parent-child relationships
  • Drag & Drop: Reorganize items
  • In-line Editing: Click to edit properties
  • Add Children: Right-click → "Add Child"
  • Export/Import: Excel format

7. Sharing & Collaboration

Sharing Equipment Types

Share standardized equipment categories with your entire team:

  1. Create or edit equipment type
  2. Check "Share Equipment Type"
  3. Click Save
  4. Now visible to all users (read-only for non-owners)

💡 Collaboration Best Practices

  • Naming Conventions: [Company]-[EquipmentType]-[Manufacturer]-[Model]-v[Version]
  • Version Control: Increment version when parameters change (1.0 → 1.1)
  • Template Ownership: Assign template owners per equipment type
  • Review Schedule: Review shared templates quarterly

8. Tips & Best Practices

💡 Tip 1: Use CSV Import for Repetitive Parameters

Don't manually create 200 VFD parameters. Get CSV from equipment manual or vendor website and bulk import in seconds.

💡 Tip 2: Always Set Min/Max Values

Bad: Motor Voltage [no limits] → User enters 999999V

Good: Motor Voltage: Min=0V, Max=1000V, Step=1V

💡 Tip 3: Use Tag Numbers Consistently

Format: [Area]-[EquipmentType]-[Number]

  • 21-VFD-001 (Area 21, VFD, #001)
  • 15-FIT-042 (Area 15, Flow Transmitter, #042)
  • MCC-E-01 (Motor Control Center, Electrical, #01)

💡 Tip 4: Always Upload Equipment Manuals

Attach PDF manuals to parameter sets for easy reference during configuration and maintenance.

9. Troubleshooting

❌ Issue: Can't Delete Equipment Type

Error: "Cannot delete equipment type because manufacturer models exist."

Solution:

  1. Go to Manufacturer Models list
  2. Filter by equipment type
  3. Delete or reassign all manufacturer models first
  4. Then delete equipment type

❌ Issue: Parameter Values Not Saving

Error: "Value must be >= 0" or "Invalid option selected"

Cause: Validation rules in parameter template.

Solution:

  1. Check parameter template min/max values
  2. For select fields, verify option exists
  3. For integer fields, remove decimal points
  4. Match units correctly (enter "480", not "480V")

❌ Issue: CSV Import Fails

Error: "Row 15: Parameter code 'P0001' already exists"

Solution:

  1. Check if parameters already exist in system
  2. CSV import updates if YOU own the parameter
  3. Cannot overwrite shared parameters from other users
  4. Change parameter codes or remove duplicate rows

10. Frequently Asked Questions

Q: What's the difference between Parameter Set and Parameter Template?

A: A Parameter Template is an individual parameter definition (e.g., "P0001: Motor Voltage"). A Parameter Set is a collection of parameter templates for a specific manufacturer model (e.g., "Siemens G120 v1.0" with 200 parameter templates).

Q: Can I use this app for non-electrical equipment?

A: Yes! The app works for any industrial equipment requiring parametric configuration:

  • HVAC systems (chillers, boilers, AHUs)
  • Process equipment (pumps, valves, analyzers)
  • Safety systems (fire panels, gas detection)
  • Building automation (lighting, access control)

Q: How many device configurations can I create?

A: Unlimited. The app uses UUID primary keys and is designed for large projects with thousands of devices.

Q: If I share an equipment type, can others edit it?

A: No. Sharing makes it read-only for other users. Only the creator can edit/delete.

Q: Can I version control parameter sets?

A: Yes! Increment the version field (1.0 → 1.1) when making changes. Old device settings continue referencing old versions.

🎯 Ready to Get Started?

Jump right in and create your first equipment configuration:

Go to Parameters Dashboard Browse Equipment Types View Manufacturer Models

Last Updated: November 2024 | App Version: 1.0
For Support: Contact your system administrator

How-to Guides