Saved calculations and networks

Your personal calculation library and PSAS networks.

With the account permission on the workspace endpoint, an assistant can work with two kinds of personal data that also appear on the fast.engineer website: your calculation library and your saved power-system (PSAS) networks. These belong to you, not to a team, and are available whichever workspace you chose — including Personal only.

Your calculation library

fe_calc_save
Saves the result of any free calculation tool. Pass the tool name and exactly the inputs used; the calculation is re-run on the server (never copied from the conversation), stored with your title, calc number, tag and description, and returned with links to its web page, print-ready report and Excel export. Saving needs the calculator to be live on the fast.engineer website as well; until it is, the tool says so and the result it returned can still be used.
fe_calc_list
Your saved calculations, newest first, with an optional search over title, calc number, tag, description and calculation type. Includes calculations saved on the website.
fe_calc_get
One saved calculation: inputs and results, and — if it was saved through MCP — the tool arguments and the provenance hashes, so it can be reproduced later.

A saved calculation is an ordinary fast.engineer calculation: you can open, edit, print and export it on the website like any other.

Saved networks (PSAS)

PSAS is fast.engineer's power-system analysis tool. Networks you build in its single-line editor can be read, built, edited and studied from an assistant — and networks an assistant builds open in the editor.

fe_network_list / fe_network_get
Find a network; read its summary (settings, element counts, recent study runs) or the full list of buses, lines, transformers, machines, utility sources or protective devices — in the same field names the edit tool takes.
fe_network_create
A new network with its title, system base (MVA), frequency, drawing number, revision and default solver (pandapower or native), optionally populated in the same step.
fe_network_edit
A list of operations applied in order, all or nothing: add, update or remove buses, lines (overhead or cable), transformers, machines, utility sources and devices (breakers or fuses, optionally with an overcurrent relay), and the study settings. References are checked before anything is saved — a line must join two existing buses at the same voltage, and an element still in use cannot be removed. Updates change only the fields given.
fe_network_study
Runs and records a study: load_flow (voltages, flows, loading, losses); fault (IEC 60909 maximum/minimum three-phase, line-to-ground, line-to-line or line-to-line-to-ground at a bus, with breaking and making duty checks of the devices there — or a classical Z-bus/MVA fault with the native solver); contingency (N-1 outages of lines and transformers); thevenin (driving-point impedance at a bus); and diagnose (data and topology problems — run this first if a study fails).
fe_network_coordinate
Grades the inverse-time overcurrent relays of a radial network: pickups above 1.25 × maximum load and checked for sensitivity against the minimum fault, time dials graded upwards from the most downstream relay with your margin at the maximum through-fault, and a selectivity report per relay pair. Optionally writes the settings back and refreshes the linked time-current-curve study.
Edits, relay settings written back and refreshed TCC curves overwrite what was there; clients mark these tools as making changes and normally ask you first. The network's run history keeps every study.

Inline or saved?

For a one-off question you do not need to save anything: fe_calc_load_flow and fe_calc_short_circuit (mode='network') take a network of up to 50 buses inline and run the same engine. Save it as a PSAS network when you want to keep it, iterate on it, see it as a single-line diagram, or grade relays on it. For whole-project design from a load list, use the team project tools instead.