Tool catalogue

Every tool: what it does, who can call it, what it costs.

The server publishes 92 tools. Every name starts with fe_; the description an assistant sees says what the tool is for, what it is not for (naming the tool to use instead) and the units of its inputs. Tools are listed to clients in this order, grouped by purpose.

How to read this table

Access
Free tools work on both endpoints with no account. Signed in tools act on your own fast.engineer data and need the workspace endpoint with the account permission. Team workspace tools act on projects in the workspace chosen at sign-in and need project:read (reading) or project:write (changing).
Cost
Quota units one call uses. Most tools cost 1; heavier ones (saving, network studies, relay grading) cost more. Listing and discovery cost nothing.
Available
Whether the tool is offered right now. A calculation tool appears only once its engine is released for MCP (see Validation and release); any tool can also be paused by an operator.
Changes data
The tool writes something (a saved calculation, a model edit, a study run). Replaces data means it can overwrite or remove existing data — clients typically ask you to confirm these.

Electrical calculations

ToolWhat it doesAccessCostAvailable
fe_calc_arc_flash
Arc-flash incident energy — IEEE 1584-2018 (single bus)
Worked examples
Calculates the arc-flash incident energy, arcing current (full and reduced), arc-flash boundary and the NFPA 70E PPE requirement at one bus per IEEE 1584-2018, from the bolted fault current, protective-device clearing times, voltage, electrode configuration, conductor gap, working distance and enclosure size.
IEEE 1584 NFPA 70E
Free 1 Yes
fe_calc_cable_permissible_load
Cable permissible load — AS/NZS 3008.1.1
Worked examples
Finds the largest three-phase load a given AS/NZS 3008.1.1 cable may carry for its installation (edition 2017 only): solves current-carrying capacity (with derating), voltage drop over the route, and protection (the largest preferred device rating that both trips on an earth fault at the far end and sits within the cable capacity, AS/NZS 3000 Clause 2.5.3.1) for the load each permits, reports the smallest as the permissible load in A, kW and kVA with the governing limit, checks short-circuit withstand and the earth conductor (AS/NZS 3000 Table 5.1 size, adiabatic withstand), and tables preferred load ratings (motor kW at an efficiency, or device ratings) showing which conform.
AS/NZS 3008.1.1 AS/NZS 3000 AS/NZS 60898
Free 1 Yes
fe_calc_cable_size
Cable sizing — AS/NZS 3008, NEC, IEC 60364
Worked examples
Sizes a power cable, or checks a given size, for one circuit: finds the smallest conductor that passes current-carrying capacity (with derating for installation, grouping and ambient), voltage drop, short-circuit withstand and earth-fault loop impedance (AS/NZS also: earth conductor size against AS/NZS 3000 Table 5.1 and earth conductor thermal withstand), and reports each check with its limit, the governing constraint and the table references used.
AS/NZS 3008.1.1 AS/NZS 3000 NEC (NFPA 70) CSA C22.1 IEC 60364-5-52
Free 1 Yes
fe_calc_cable_size_range
Cable size range — AS/NZS 3008.1.1
Worked examples
Finds every standard conductor size (1 to 630 mm²) that conforms for one three-phase AS/NZS 3008.1.1 load cable (edition 2017 only): each size is checked for current-carrying capacity (with installation, grouping and ambient derating), voltage drop, short-circuit withstand, earth-fault loop impedance, overload coordination with the protective device (AS/NZS 3000 Clause 2.5.3.1), and the earth conductor's Table 5.1 size and thermal withstand, using the Table 5.1 minimum earth.
AS/NZS 3008.1.1 AS/NZS 3000
Free 1 Awaiting release
fe_calc_earthing
Earth grid and earthing conductor design — IEEE 80, AS/NZS 3000
Worked examples
Earthing design.
IEEE 80 AS/NZS 3000 IEC 60364-5-54
Free 1 Yes
fe_calc_efli
Earth fault-loop impedance — AS/NZS 3000, IEC 60364-4-41, BS 7671
Worked examples
Checks the earth fault-loop impedance Zs of a circuit protected by a B, C or D curve circuit breaker: Zs from the active and earth conductors (optionally a supplementary earth in parallel and the supply transformer), against Zmax for instantaneous tripping, plus the AS/NZS 3000 Table 8.2 resistance and Table B1 length limits where tabulated, and the maximum route length that still meets them.
AS/NZS 3000 IEC 60364-4-41 BS 7671
Free 1 Yes
fe_calc_generator
Generator sizing — ISO 8528-1
Worked examples
Selects a standard generator kVA rating for a load list: diversified running load, the worst single motor start (largest motor starting kVA on top of the running load), a safety margin, utilisation, fuel use and optionally tank autonomy and an N-unit parallel set with its N−1 capacity.
ISO 8528-1
Free 1 Yes
fe_calc_harmonics
VSD harmonic distortion — IEEE 519, IEC 61000-2-2
Worked examples
Estimates harmonic current and voltage distortion at a bus fed with variable speed drives (6/12/18/24-pulse, line reactor, DC choke or active front end) from the bus fault level, and checks the results against IEEE 519 current/voltage limits and IEC 61000-2-2 compatibility levels; reports THDi, THDv, short-circuit ratio, K-factor and the harmonic spectrum.
IEEE 519 IEC 61000-2-2
Free 1 Awaiting release
fe_calc_lightning_risk
Lightning risk assessment (R1) — IEC 62305-2
Worked examples
Assesses the lightning risk of loss of human life (R1) for a rectangular structure from its size, the ground flash density and its location, occupancy, fire risk and internal systems; compares it with the tolerable 1e-5 per year and recommends the lightning protection level (with rolling-sphere radius and mesh size) that achieves it.
IEC 62305-2 IEC 62305-3
Free 1 Awaiting release
fe_calc_load_flow
Load flow (inline network) — IEEE 399
Worked examples
Balanced three-phase load flow of a small network given inline (≤50 buses; one SLACK bus, PV and PQ buses; cables/lines, transformers with off-nominal taps, shunts).
IEEE 399
Free 1 Awaiting release
fe_calc_max_demand
Maximum demand — AS/NZS 3000, NEC
Worked examples
Calculates maximum demand: AS/NZS 3000 Appendix C for a single domestic installation (Table C1) or non-domestic installations (Table C2), NEC Article 220 for a three-phase panel (with panel rating and feeder size), or a load list by duty/standby quantities and load factors rolled up a board hierarchy with per-board diversity, growth and spare capacity (method 'duty_standby_lf').
AS/NZS 3000 NFPA 70 (NEC)
Free 1 Awaiting release
fe_calc_motor
Induction motor current and performance — IEC 60034-1
Worked examples
Induction motor calculations.
IEC 60034-1
Free 1 Awaiting release
fe_calc_motor_cable_chart
Motor cable selection chart — AS/NZS 3008.1.1
Worked examples
Builds a motor cable selection chart for one AS/NZS 3008.1.1 three-phase cable construction and installation (edition 2017 only): rows are IEC 60072 preferred motor ratings in [kw_min, kw_max] (full-load current at the power factor and efficiency, design current × design factor, the smallest preferred device rating above it and its earth-fault disconnection current), columns are standard cable sizes in [size_min_mm2, size_max_mm2] plus optional parallel columns (derated capacity I_Z, R and X).
AS/NZS 3008.1.1 AS/NZS 3000 IEC 60072-1
Free 1 Awaiting release
fe_calc_pfc
Power-factor correction capacitor bank — IEC 60831-1
Worked examples
Sizes a power-factor correction capacitor bank for a maximum demand and target power factor, checks parallel resonance of the installed bank with the supply against the 3rd/5th/7th/11th/13th harmonics present, adds a detuning reactor (14 / 7 / 5.67 %, or a forced choice) when needed, and reports the bank output and capacitor nameplate rating, capacitor voltage and current, capacitance, protection, discharge resistor, inrush and losses.
IEC 60871-1 IEC 60831-1 IEEE 18 IEEE 1036
Free 1 Awaiting release
fe_calc_power
Voltage, current and power (single- and three-phase)
Worked examples
Solves the power triangle of one single-phase or balanced three-phase circuit: give two of voltage, current and power with the power factor (and efficiency for equipment rated by output) and it returns the third plus active, apparent and reactive power and the phase angle. Free 1 Awaiting release
fe_calc_protection
Protection checks — AS/NZS 3000, IEC 60255-151
Worked examples
Checks protective devices.
AS/NZS 3000 IEC 60255-151 IEEE C37.112 IEC 60947-2 IEC 61869-2
Free 1 Awaiting release
fe_calc_short_circuit
Short-circuit current — IEC 60909-0
Worked examples
Calculates prospective short-circuit current.
IEC 60909-0 NFPA 70 (NEC)
Free 1 Awaiting release
fe_calc_transformer
Transformer rating selection — IEC 60076-1
Worked examples
Selects the standard kVA rating of a distribution or power transformer for a given maximum demand, with growth and overload margins, and reports impedance, losses, efficiency, regulation, LV terminal fault level, altitude derating and winding temperature.
IEC 60076-1 AS/NZS 60076-1
Free 1 Awaiting release
fe_calc_ups
UPS and battery sizing — IEC 62040-3, IEEE 485
Worked examples
Selects a standard UPS kVA rating for a critical load with safety and growth margins, and estimates battery runtime for a given battery string arrangement (Peukert, depth of discharge, end-of-life, temperature and ageing derating), including the number of strings needed for a target runtime.
IEC 62040-3 IEEE 485 IEEE 1184
Free 1 Awaiting release
fe_calc_voltage_drop
Voltage drop — AS/NZS 3008.1.1, IEC 60364, BS 7671
Worked examples
Checks voltage drop against a limit measured from the point of supply.
AS/NZS 3008.1.1 AS/NZS 3000 IEC 60364 BS 7671
Free 1 Awaiting release

Mechanical calculations

ToolWhat it doesAccessCostAvailable
fe_calc_conveyor
Belt conveyor sizing — ISO 5048, DIN 22101, CEMA
Worked examples
Preliminary belt conveyor design: belt width for the capacity, belt and material loads, rolling and lift resistance, drive power with service factor and drive-train efficiency for the loaded and the empty belt (declines: motoring or regenerative, flagged with the braking power to absorb), standard motor, belt tensions from the drive wrap, gearbox ratio and take-up travel and force.
ISO 5048 DIN 22101 CEMA Belt Conveyors for Bulk Materials
Free 1 Awaiting release
fe_calc_heat_load
Switchroom heat load and AC sizing
Worked examples
Estimates the cooling load of a switchroom or electrical equipment room — equipment losses, fabric conduction, solar gain, lighting, occupants and infiltration (sensible and latent) — adds a safety margin and counts the AC units needed, with optional standby units. Free 1 Awaiting release
fe_calc_pump
Pump head and suction (NPSH / NPIP) check — ANSI/HI 9.6.1
Worked examples
Pump system hydraulics for a given duty.
ANSI/HI 9.6.1 ANSI/HI 6.6
Free 1 Awaiting release

Utilities

ToolWhat it doesAccessCostAvailable
fe_util_conductor_size
Conductor size equivalence (AWG / kcmil / mm²)
Gives the cross-sectional area of an AWG, kcmil or metric conductor and the nearest standard size at or above it in the other system — e.g.
IEC 60228 ASTM B258
Free 1 Yes
fe_util_convert
Unit conversion
Converts a value between engineering units (length, area incl. Free 1 Yes
fe_util_per_unit
Per-unit and impedance base conversions
Per-unit arithmetic for three-phase systems: base impedance/current, ohm ↔ per unit, change of base, and a transformer's %Z on its rating to ohms referred to either winding. Free 1 Yes

Reference

ToolWhat it doesAccessCostAvailable
fe_ref_standards
Standards index
Lists the standards and editions the fast.engineer calculation tools implement, and which tool uses each. Free 1 Yes
fe_ref_validation
Validation scorecard
Reports how each calculation tool fared against the worked-example validation corpus in the latest published run: cases, passed, failed and skipped (licensed standards data not installed), with the build and corpus version, and whether that run matches the build answering now. Free 1 Yes

Your calculations

ToolWhat it doesAccessCostAvailable
fe_account_file_delete
Delete a stored file
Deletes one file (and its bytes) from your account file store.
Replaces data
Signed in or agent key
account
1 Yes
fe_account_file_download_url
Get a link to download a stored file
Returns a signed URL (valid 15 minutes) to download one file from your account file store. Signed in or agent key
account
1 Yes
fe_account_file_list
List my stored files
Lists the files in your account file store, newest first, with ids for fe_account_file_download_url and fe_account_file_delete, and your storage use. Signed in or agent key
account
1 Yes
fe_account_file_upload_url
Get a link to upload a file to my file store
Worked example
Creates an empty file in your account file store and returns a signed, single-use URL: PUT the file's bytes to it (e.g.
Changes data
Signed in or agent key
account
1 Yes
fe_agent_claim
Keep this agent's data: send a claim link to an email
Agent keys only.
Changes data
Signed in or agent key
account
1 Yes
fe_calc_get
Read a saved calculation
Reads one calculation from your fast.engineer calcs library: its saved inputs and results, the tool arguments and provenance hashes if it was saved through fe_calc_save, and links to the web page, print-ready report and Excel export. Signed in or agent key
account
1 Yes
fe_calc_list
List my saved calculations
Lists the calculations saved in your fast.engineer calcs library (from the website or fe_calc_save), newest first, with ids for fe_calc_get. Signed in or agent key
account
1 Yes
fe_calc_save
Save a calculation to my library
Saves the result of a free calculation tool (fe_calc_*) to your fast.engineer calcs library: the calculation is re-run with the same inputs, stored with your title, calc number and tag, and returned with links to the web page, the print-ready report and the Excel export.
Changes data
Signed in or agent key
account
2 Yes

Saved networks (PSAS)

ToolWhat it doesAccessCostAvailable
fe_network_coordinate
Grade overcurrent relays on a saved network
Grades and optionally optimises the inverse-time overcurrent relays (devices with relay_enabled) on one of your saved radial networks: pickups above 1.25 × maximum load and checked for sensitivity against the IEC 60909 minimum fault, time dials graded from the most downstream relay upwards with the required margin at the maximum through-fault, and a selectivity report per relay pair.
IEC 60255-151 IEC 60909-0
Replaces data
Signed in or agent key
account
5 Yes
fe_network_create
Create a saved network
Creates a new power-system network in your fast.engineer account, optionally populated in one step with the same ops fe_network_edit takes (buses first, then lines/transformers, sources, machines, devices).
Changes data
Signed in or agent key
account
1 Yes
fe_network_edit
Edit a saved network
Changes one of your saved networks with a list of ops applied in order, all-or-nothing: add_/update_/remove_ bus, line (overhead line or cable), transformer, machine, source (utility infeed) and device (breaker/fuse, optionally an overcurrent relay), and set_study_settings.
Replaces data
Signed in or agent key
account
2 Yes
fe_network_get
Read a saved network
Reads one of your saved networks: a summary (settings, element counts, recent study runs) or the full list of buses, lines, transformers, machines, utility sources or protective devices. Signed in or agent key
account
1 Yes
fe_network_list
List my saved networks
Lists the power-system networks saved in your fast.engineer account (PSAS), newest first, with ids to use in the other fe_network_* tools. Signed in or agent key
account
1 Yes
fe_network_study
Study a saved network
Runs a study on one of your saved networks and records it in the network's run history: load_flow (bus voltages, branch flows and loading, losses), fault (IEC 60909 max/min three-phase, line-to-ground, line-to-line or line-to-line-to-ground fault at a bus with breaking/making duty checks of the devices there — pandapower; or a classical Z-bus/MVA three-phase fault — native), contingency (N-1 line/transformer outages), thevenin (driving-point impedance at a bus) or diagnose (data and topology problems).
IEC 60909-0
Changes data
Signed in or agent key
account
3 Yes

Team projects

ToolWhat it doesAccessCostAvailable
fe_file_upload_url
Get a file upload link
Worked example
Returns a one-time HTTPS link to upload a load list (.xlsx or .csv), a PDF, or a drawing (.pdf, .dxf, .dwg, .png, .jpg, .tif) into a project: PUT the raw file bytes to upload_url within 15 minutes (max 25 MB), then pass file_id to fe_loadlist_import_preview or fe_drawing_digitize.
Changes data
Team workspace
project:write
1 Yes
fe_job_cancel
Cancel a job
Cancels a queued or running study job; a running job stops at its next checkpoint and keeps no results.
Replaces data
Team workspace
project:write
1 Yes
fe_job_get
Job status and summary
Status, progress and the exceptions-first summary of a study job (e.g. Team workspace
project:read
1 Yes
fe_loadlist_import_commit
Commit a load-list import
Writes a previewed load-list import into its draft revision: creates or updates loads (matched by tag), a supply cable per new load (cable number from the list or 'C-<tag>'), and missing boards.
Replaces data
Team workspace
project:write
1 Yes
fe_loadlist_import_preview
Preview a load-list import
Reads an uploaded load list (.xlsx/.csv, ≤20,000 rows) or the project's load design list and shows, without changing the model, how it would import: the column → field mapping with a confidence per column, unmapped headers, row problems, boards that exist or would be created, and sample rows.
Changes data Interactive view
Team workspace
project:write
1 Yes
fe_model_create
Create a network model
Creates a new electrical network model in a project with its first draft revision 'A' and its design basis (standard and edition, voltage-drop budget, ambient conditions, default cable installation, demand method, growth and spare).
Changes data
Team workspace
project:write
1 Yes
fe_model_edit
Edit a network model
Adds, updates or deletes elements of a draft revision in one all-or-nothing batch: buses, sources (grid or generator), transformers, loads, cables, protective devices and fault scenarios.
Replaces data
Team workspace
project:write
1 Yes
fe_model_get
Read a network model revision
Reads one revision of a network model: view='summary' gives the design basis and element counts; the other views page through buses, sources, transformers, loads, cables, protective devices or scenarios with every editable field (references shown by tag), as fe_model_edit expects them. Team workspace
project:read
1 Yes
fe_model_list
List network models
Lists a project's network models and their revisions (label, status, parent) with the revision ids the other tools take. Team workspace
project:read
1 Yes
fe_project_list
List projects
Lists the projects in this team workspace that you can open, with your access (read or write) and how many network models each holds. Team workspace
project:read
1 Yes
fe_qa_check
Model QA
Checks a revision without running studies: sources and connectivity, loops and multiple feeds, voltage mismatches, missing data, duplicate tags and cable numbers, transformer overload against design demand, spare ways, single-phase imbalance, unprotected cables, and (after a sizing run) cumulative voltage drop over budget. Team workspace
project:read
1 Yes
fe_report_generate
Generate the calculation report
Renders a revision's calculation report as PDF — revision history, design basis, exceptions first, maximum demand, fault levels, cable schedule with governing checks, assumptions, clause references, engine build and an unsigned sign-off block — and returns a 15-minute download link.
Changes data
Team workspace
project:write
1 Yes
fe_results_get
Study results by element
Pages through a finished job's per-element results (failures first): pass/fail, governing check, headline values, and optionally each element's full provenance envelope (checks with limits, clause references, assumptions, hashes). Interactive view Team workspace
project:read
1 Yes
fe_revision_create
Create a revision
Branches a new draft revision from an existing one (any status): every element is copied with the same uid, so fe_revision_diff shows exactly what changes afterwards.
Changes data
Team workspace
project:write
1 Yes
fe_revision_diff
Compare revisions
Change register between two revisions of the same model: elements added, removed and modified (field by field, references by tag) and design-basis changes, matched by each element's stable uid. Team workspace
project:read
1 Yes
fe_revision_set_status
Set revision status
Moves a revision through draft → checked → approved → issued (checked may return to draft).
Replaces data
Team workspace
project:write
1 Yes
fe_schedule_export
Export the cable schedule
Exports a revision's cable schedule as .xlsx or .csv (cable number, route, size, earth, installation, design current, capacity, voltage drop, status and governing check, run id and result hash per line) and returns a 15-minute download link.
Changes data
Team workspace
project:write
1 Yes
fe_study_fault
Fault level study
IEC 60909 fault levels at every bus and load terminal of a revision: Ik'' max and ip, Ik'' min, earth-fault Ik1 min and the loop impedance Zs, checked against busbar ratings and cross-checked by the MVA method.
Changes data
Team workspace
project:write
1 Yes
fe_study_max_demand
Maximum demand study
Maximum demand of every board in a revision by the duty/standby + load-factor method: running kW/kVAr per load, diversity per board compounding up the supply tree, growth and spare on each board's design demand, and transformer loading against design demand.
Changes data
Team workspace
project:write
1 Yes
fe_study_protection
Protection check
Checks every protective device of a revision: Ib ≤ In ≤ Iz, breaking capacity Icu ≥ Ik''max, adiabatic withstand of the cable and earth-fault loop impedance against the magnetic trip current.
Changes data
Team workspace
project:write
1 Yes
fe_study_size_cables
Size all cables
Sizes (or checks) every cable of a revision with the fe_calc_cable_size engine, top-down: design currents from maximum demand, Ik''max and Zs from a fault study re-solved with the new sizes until they stop changing (≤3 times), a voltage-drop limit from the revision budget.
Replaces data
Team workspace
project:write
1 Yes

Drawings

ToolWhat it doesAccessCostAvailable
fe_block_create
Create a library block
Worked example
Draws a new library block (symbol) from primitives — lines, polylines, rectangles, circles, arcs and texts — plus named connection nodes, and files it in a library under a style.
Changes data
Team workspace
project:write
1 Yes
fe_block_get
Read a library block
Worked example
Reads one library block by id: its symbol name, library, sub-category, style, size, connection nodes, whether it is ready for use / a draft, and (unless include_document is false) its drawing document — the shapes front_diagram renders, in block coordinates (format 'block-coordinates': y UP from the block's bottom-left corner). Team workspace
project:read
1 Yes
fe_block_list
List library blocks
Worked example
Lists the workspace's symbol libraries and the blocks a block diagram can place: active, ready-for-use blocks (drafts and archived blocks are hidden; fe_block_get still reads them by id), with each block's style, size and connection nodes (label, position as a fraction of the block from its top-left, side it faces). Team workspace
project:read
1 Yes
fe_diagram_create
Create a block diagram
Worked example
Builds a new block diagram in a project from library blocks (fe_block_list), plain rectangles and text notes, wired together, and returns its editor link with the new shape and connection ids.
Changes data
Team workspace
project:write
2 Yes
fe_diagram_edit
Edit a block diagram
Worked example
Changes a block diagram in one all-or-nothing batch, the way the editor does: only the diagram document is saved, its database rows are not updated (the same as an editor save).
Replaces data
Team workspace
project:write
1 Yes
fe_diagram_export
Export a block diagram
Worked example
Exports a block diagram through the server's QCAD pipeline as DWG, DXF, PDF, SVG or PNG and returns a download link valid for 15 minutes; each export also records a published revision of the diagram.
Changes data
Team workspace
project:write
3 Yes
fe_diagram_get
Read a block diagram
Worked example
Reads a block diagram as the editor last saved it: every shape (id, type, library block id and name for symbols, text, top-left x,y, width, height, rotation) and every connection as from_node/to_node '<shape_id>.<node label>' with its style and title. Team workspace
project:read
1 Yes
fe_diagram_list
List block diagrams
Worked example
Lists a project's block diagrams (front_diagram documents), newest first: style, paper size, shape and connection counts, the editor link, and from_sheet_id when the diagram was digitized from a drawing sheet. Team workspace
project:read
1 Yes
fe_drawing_digitize
Digitize a drawing
Worked example
Starts digitizing an uploaded drawing (get file_id from fe_file_upload_url: PDF, PNG/JPG/TIFF scan, or DXF/DWG): creates a drawing batch, splits it into one sheet per page and, with auto_process, runs the whole pipeline — geometry, OCR, border and title block, shapes/tables/dashed lines, symbol matching, wiring and a block diagram you can open in the editor.
Changes data
Team workspace
project:write
3 Yes
fe_drawing_geometry_get
Read sheet geometry
Worked example
Pages through a sheet's vector primitives — lines, polylines, rectangles, circles, arcs, curves and text spans — optionally only some kinds, only those overlapping a bbox, and either the live geometry or the snapshot taken after one pipeline stage (stage_key). Team workspace
project:read
1 Yes
fe_drawing_process
Start or resume drawing processing
Worked example
Starts or resumes a drawing batch's pipeline once its pages are split: after fe_drawing_digitize with auto_process=false, after fe_drawing_stop, or after a failure.
Changes data
Team workspace
project:write
2 Yes
fe_drawing_review_decide
Answer connection review
Worked example
Answers connection-review questions with option keys from fe_drawing_review_issues (all or none) and, once nothing is left undecided, continues the pipeline to build the block diagram — re-tracing the wiring first if an answer rotated or removed a symbol.
Changes data
Team workspace
project:write
1 Yes
fe_drawing_review_issues
Connection review questions
Worked example
Lists the questions a sheet's connection review raised before its block diagram is built — weak wire links, symbols whose rotation is ambiguous, overlapping symbols and weak symbol matches — each with its facts, whether it is decided, and the closed list of options to answer it with (fe_drawing_review_decide), plus a link to the review page. Team workspace
project:read
1 Yes
fe_drawing_sheet_export
Export a sheet
Worked example
Exports one sheet as a file and returns a 15-minute download link: svg or png renders the sheet's vector geometry (the live geometry or the snapshot after one stage, optionally only a bbox); source_pdf is the sheet's original PDF page.
Changes data
Team workspace
project:write
2 Yes
fe_drawing_sheet_get
Read a digitized sheet
Worked example
Reads one section of a digitized sheet: summary (primitive counts, bounds, symbol and connection counts, block diagram, AI-review verdict), titleblock (fields read from the title block), symbols (matched library symbols with box, rotation, score, text read inside them and every pin with its traced link), connections (the reviewed wire links between pins), detections (classified shapes, tables, dashed lines, revision clouds, fills, wire ends), review (the ai_review debrief, a Gemini review of the finished diagram on the batch creator's key) or log (processing log). Team workspace
project:read
1 Yes
fe_drawing_status
Drawing batch status
Worked example
Reports a drawing batch's progress: a headline, the overall phase, and per sheet its phase (failed, awaiting_review, waiting_source, running, queued, stopped, done, idle), the stage it is on, every pipeline stage's state and message, the block diagram id with an editor link once built, and the connection-review count when a sheet waits for decisions. Team workspace
project:read
1 Yes
fe_drawing_stop
Stop a drawing batch
Worked example
Stops all processing of a drawing batch: revokes its queued and running pipeline tasks and marks the running stages stopped (a pause, not a failure).
Replaces data
Team workspace
project:write
1 Yes
fe_drawing_symbol_sets
List symbol libraries
Worked example
Lists the symbol libraries (symbol sets) a project's drawings can be matched against — the project's own and the team-shared ones — with how many active symbols each holds and how many can match vector geometry (PDF/DXF) or raster crops (scans). Team workspace
project:read
1 Yes

Sign-off marketplace

ToolWhat it doesAccessCostAvailable
fe_market_certification_get
Get the signed certification
Returns a certified sign-off request's signed documents: for each certification artefact (e.g. Signed in or agent key
marketplace
1 Awaiting release
fe_market_change_request_respond
Resubmit after a change request
Answers the reviewer's change request on a sign-off request: once the revised documents have been added (fe_market_document_add — at least one is required), it relocks the bundle as the next version with a new SHA-256, resolves the open change requests and puts the review back in progress; the reviewer re-confirms the checklist items against the new version.
Changes data
Signed in or agent key
marketplace
1 Awaiting release
fe_market_document_add
Add a document to a sign-off bundle
Worked example
Copies a file from your account file store into a sign-off request's review bundle, with its kind and whether an AI tool produced it (and which tool/model).
Changes data
Signed in or agent key
marketplace
1 Awaiting release
fe_market_engineer_search
Find eligible sign-off reviewers
Worked example
Lists registered engineers who could sign off a project today: each holds a registration the state's scheme accepts for the discipline (checked on the public register recently), professional indemnity insurance in force, approved identity, and is taking work. Signed in or agent key
marketplace
1 Awaiting release
fe_market_estimate_accept
Accept a quote
Accepts one quote on your sign-off request and confirms its scope for the client: the other quotes are declined, a single-milestone agreement for the full fee is created and the engineer is asked to confirm it (their eligibility is re-checked).
Changes data
Signed in or agent key
marketplace
2 Awaiting release
fe_market_estimates_list
Read quotes on a sign-off request
Lists the quotes (estimates) registered engineers have submitted on one of your sign-off requests: total fee and review fee in AUD (the review fee is what the engineer keeps if they reject the bundle outright), proposed timeline, assumptions, exclusions and qualifications, and an anonymised summary of the engineer with their public register entries. Signed in or agent key
marketplace
1 Awaiting release
fe_market_request_status
Sign-off request status
Worked example
Reports where a sign-off request stands and the one next step: the job status, the bundle (version, lock hash, missing document kinds), how many quotes have been submitted, the agreement and contract once a quote is accepted, the review's status (awaiting_funds comes with funding_url — the escrow page a person must use), open change requests from the reviewer, and whether the certification is ready. Signed in or agent key
marketplace
1 Awaiting release
fe_market_request_submit
Submit a sign-off request
Worked example
Checks a draft sign-off request's bundle (every required document kind present, AI declaration consistent with the documents), locks it — freezing its SHA-256 so the reviewer certifies exactly these files — and opens the request to eligible registered engineers, who are notified and can quote.
Changes data
Signed in or agent key
marketplace
2 Awaiting release
fe_market_requests_list
List my sign-off requests
Worked example
Lists the account's sign-off requests, newest first, with id, title, state, discipline, status, when and through which channel (web or mcp) each was created — whether posted by an agent or on the website. Signed in or agent key
marketplace
1 Awaiting release
fe_market_review_request_create
Create a sign-off request
Worked example
Creates a draft request for a registered Australian engineer to review and certify documents (one discipline per request), on behalf of the signed-in account, with its AI-use declaration — say truthfully whether AI tools prepared the documents, which ones, and what a person checked; it is recorded in the certification.
Changes data
Signed in or agent key
marketplace
2 Awaiting release
fe_market_schemes
Australian sign-off schemes
Worked example
Explains which engineering registration a sign-off needs in an Australian state: the registration scheme (RPEQ, NSW DBP, VIC PER, ACT PER, WA building engineer or the national NER), whether it is mandatory yet, the accepted registration types and levels, the certification artefact issued (e.g. Free 1 Awaiting release

Choosing between similar tools

You wantUse
Select or verify one cablefe_calc_cable_size (sizing_mode auto or check)
Voltage drop of a known cable or a lighting run, or the longest motor run within a limitfe_calc_voltage_drop
Fault level along one radial pathfe_calc_short_circuit with mode='point_to_point'
Fault levels on a small network you describe inlinefe_calc_short_circuit with mode='network'
Studies on a network you keepfe_network_study on a saved PSAS network
Size every cable on a projectfe_study_size_cables on a team model
A transformer's own terminal fault levelfe_calc_transformer
Any unit or per-unit conversionfe_util_convert, fe_util_conductor_size, fe_util_per_unit
Turn an uploaded drawing into symbols, wiring and a block diagramfe_drawing_digitize, then poll fe_drawing_status
Get a stopped, failed or idle digitization moving againfe_drawing_process (continue); answering its review questions is fe_drawing_review_decide
The digitized geometry itself (lines, text, circles)fe_drawing_geometry_get; matched symbols and wires are fe_drawing_sheet_get
Draw a block diagram from library symbolsfe_diagram_create, corrections with fe_diagram_edit, CAD files with fe_diagram_export
A symbol the library lacksfe_block_create (workspace-wide; check fe_block_list first)

Common inputs