Tool catalogue
Every tool: what it does, who can call it, what it costs.
The server publishes 92 tools. Every name starts with fe_; the description an assistant
sees says what the tool is for, what it is not for (naming the tool to use instead) and the units of its
inputs. Tools are listed to clients in this order, grouped by purpose.
How to read this table
- Access
- Free tools work on both endpoints with no account. Signed in tools act on your
own fast.engineer data and need the workspace endpoint with the
accountpermission. Team workspace tools act on projects in the workspace chosen at sign-in and needproject:read(reading) orproject:write(changing). - Cost
- Quota units one call uses. Most tools cost 1; heavier ones (saving, network studies, relay grading) cost more. Listing and discovery cost nothing.
- Available
- Whether the tool is offered right now. A calculation tool appears only once its engine is released for MCP (see Validation and release); any tool can also be paused by an operator.
- Changes data
- The tool writes something (a saved calculation, a model edit, a study run). Replaces data means it can overwrite or remove existing data — clients typically ask you to confirm these.
Electrical calculations
| Tool | What it does | Access | Cost | Available |
|---|---|---|---|---|
fe_calc_arc_flashArc-flash incident energy — IEEE 1584-2018 (single bus) Worked examples |
Calculates the arc-flash incident energy, arcing current (full and reduced), arc-flash boundary and the NFPA 70E PPE requirement at one bus per IEEE 1584-2018, from the bolted fault current, protective-device clearing times, voltage, electrode configuration, conductor gap, working distance and enclosure size.
IEEE 1584 NFPA 70E |
Free | 1 | Yes |
fe_calc_cable_permissible_loadCable permissible load — AS/NZS 3008.1.1 Worked examples |
Finds the largest three-phase load a given AS/NZS 3008.1.1 cable may carry for its installation (edition 2017 only): solves current-carrying capacity (with derating), voltage drop over the route, and protection (the largest preferred device rating that both trips on an earth fault at the far end and sits within the cable capacity, AS/NZS 3000 Clause 2.5.3.1) for the load each permits, reports the smallest as the permissible load in A, kW and kVA with the governing limit, checks short-circuit withstand and the earth conductor (AS/NZS 3000 Table 5.1 size, adiabatic withstand), and tables preferred load ratings (motor kW at an efficiency, or device ratings) showing which conform.
AS/NZS 3008.1.1 AS/NZS 3000 AS/NZS 60898 |
Free | 1 | Yes |
fe_calc_cable_sizeCable sizing — AS/NZS 3008, NEC, IEC 60364 Worked examples |
Sizes a power cable, or checks a given size, for one circuit: finds the smallest conductor that passes current-carrying capacity (with derating for installation, grouping and ambient), voltage drop, short-circuit withstand and earth-fault loop impedance (AS/NZS also: earth conductor size against AS/NZS 3000 Table 5.1 and earth conductor thermal withstand), and reports each check with its limit, the governing constraint and the table references used.
AS/NZS 3008.1.1 AS/NZS 3000 NEC (NFPA 70) CSA C22.1 IEC 60364-5-52 |
Free | 1 | Yes |
fe_calc_cable_size_rangeCable size range — AS/NZS 3008.1.1 Worked examples |
Finds every standard conductor size (1 to 630 mm²) that conforms for one three-phase AS/NZS 3008.1.1 load cable (edition 2017 only): each size is checked for current-carrying capacity (with installation, grouping and ambient derating), voltage drop, short-circuit withstand, earth-fault loop impedance, overload coordination with the protective device (AS/NZS 3000 Clause 2.5.3.1), and the earth conductor's Table 5.1 size and thermal withstand, using the Table 5.1 minimum earth.
AS/NZS 3008.1.1 AS/NZS 3000 |
Free | 1 | Awaiting release |
fe_calc_earthingEarth grid and earthing conductor design — IEEE 80, AS/NZS 3000 Worked examples |
Earthing design.
IEEE 80 AS/NZS 3000 IEC 60364-5-54 |
Free | 1 | Yes |
fe_calc_efliEarth fault-loop impedance — AS/NZS 3000, IEC 60364-4-41, BS 7671 Worked examples |
Checks the earth fault-loop impedance Zs of a circuit protected by a B, C or D curve circuit breaker: Zs from the active and earth conductors (optionally a supplementary earth in parallel and the supply transformer), against Zmax for instantaneous tripping, plus the AS/NZS 3000 Table 8.2 resistance and Table B1 length limits where tabulated, and the maximum route length that still meets them.
AS/NZS 3000 IEC 60364-4-41 BS 7671 |
Free | 1 | Yes |
fe_calc_generatorGenerator sizing — ISO 8528-1 Worked examples |
Selects a standard generator kVA rating for a load list: diversified running load, the worst single motor start (largest motor starting kVA on top of the running load), a safety margin, utilisation, fuel use and optionally tank autonomy and an N-unit parallel set with its N−1 capacity.
ISO 8528-1 |
Free | 1 | Yes |
fe_calc_harmonicsVSD harmonic distortion — IEEE 519, IEC 61000-2-2 Worked examples |
Estimates harmonic current and voltage distortion at a bus fed with variable speed drives (6/12/18/24-pulse, line reactor, DC choke or active front end) from the bus fault level, and checks the results against IEEE 519 current/voltage limits and IEC 61000-2-2 compatibility levels; reports THDi, THDv, short-circuit ratio, K-factor and the harmonic spectrum.
IEEE 519 IEC 61000-2-2 |
Free | 1 | Awaiting release |
fe_calc_lightning_riskLightning risk assessment (R1) — IEC 62305-2 Worked examples |
Assesses the lightning risk of loss of human life (R1) for a rectangular structure from its size, the ground flash density and its location, occupancy, fire risk and internal systems; compares it with the tolerable 1e-5 per year and recommends the lightning protection level (with rolling-sphere radius and mesh size) that achieves it.
IEC 62305-2 IEC 62305-3 |
Free | 1 | Awaiting release |
fe_calc_load_flowLoad flow (inline network) — IEEE 399 Worked examples |
Balanced three-phase load flow of a small network given inline (≤50 buses; one SLACK bus, PV and PQ buses; cables/lines, transformers with off-nominal taps, shunts).
IEEE 399 |
Free | 1 | Awaiting release |
fe_calc_max_demandMaximum demand — AS/NZS 3000, NEC Worked examples |
Calculates maximum demand: AS/NZS 3000 Appendix C for a single domestic installation (Table C1) or non-domestic installations (Table C2), NEC Article 220 for a three-phase panel (with panel rating and feeder size), or a load list by duty/standby quantities and load factors rolled up a board hierarchy with per-board diversity, growth and spare capacity (method 'duty_standby_lf').
AS/NZS 3000 NFPA 70 (NEC) |
Free | 1 | Awaiting release |
fe_calc_motorInduction motor current and performance — IEC 60034-1 Worked examples |
Induction motor calculations.
IEC 60034-1 |
Free | 1 | Awaiting release |
fe_calc_motor_cable_chartMotor cable selection chart — AS/NZS 3008.1.1 Worked examples |
Builds a motor cable selection chart for one AS/NZS 3008.1.1 three-phase cable construction and installation (edition 2017 only): rows are IEC 60072 preferred motor ratings in [kw_min, kw_max] (full-load current at the power factor and efficiency, design current × design factor, the smallest preferred device rating above it and its earth-fault disconnection current), columns are standard cable sizes in [size_min_mm2, size_max_mm2] plus optional parallel columns (derated capacity I_Z, R and X).
AS/NZS 3008.1.1 AS/NZS 3000 IEC 60072-1 |
Free | 1 | Awaiting release |
fe_calc_pfcPower-factor correction capacitor bank — IEC 60831-1 Worked examples |
Sizes a power-factor correction capacitor bank for a maximum demand and target power factor, checks parallel resonance of the installed bank with the supply against the 3rd/5th/7th/11th/13th harmonics present, adds a detuning reactor (14 / 7 / 5.67 %, or a forced choice) when needed, and reports the bank output and capacitor nameplate rating, capacitor voltage and current, capacitance, protection, discharge resistor, inrush and losses.
IEC 60871-1 IEC 60831-1 IEEE 18 IEEE 1036 |
Free | 1 | Awaiting release |
fe_calc_powerVoltage, current and power (single- and three-phase) Worked examples |
Solves the power triangle of one single-phase or balanced three-phase circuit: give two of voltage, current and power with the power factor (and efficiency for equipment rated by output) and it returns the third plus active, apparent and reactive power and the phase angle. | Free | 1 | Awaiting release |
fe_calc_protectionProtection checks — AS/NZS 3000, IEC 60255-151 Worked examples |
Checks protective devices.
AS/NZS 3000 IEC 60255-151 IEEE C37.112 IEC 60947-2 IEC 61869-2 |
Free | 1 | Awaiting release |
fe_calc_short_circuitShort-circuit current — IEC 60909-0 Worked examples |
Calculates prospective short-circuit current.
IEC 60909-0 NFPA 70 (NEC) |
Free | 1 | Awaiting release |
fe_calc_transformerTransformer rating selection — IEC 60076-1 Worked examples |
Selects the standard kVA rating of a distribution or power transformer for a given maximum demand, with growth and overload margins, and reports impedance, losses, efficiency, regulation, LV terminal fault level, altitude derating and winding temperature.
IEC 60076-1 AS/NZS 60076-1 |
Free | 1 | Awaiting release |
fe_calc_upsUPS and battery sizing — IEC 62040-3, IEEE 485 Worked examples |
Selects a standard UPS kVA rating for a critical load with safety and growth margins, and estimates battery runtime for a given battery string arrangement (Peukert, depth of discharge, end-of-life, temperature and ageing derating), including the number of strings needed for a target runtime.
IEC 62040-3 IEEE 485 IEEE 1184 |
Free | 1 | Awaiting release |
fe_calc_voltage_dropVoltage drop — AS/NZS 3008.1.1, IEC 60364, BS 7671 Worked examples |
Checks voltage drop against a limit measured from the point of supply.
AS/NZS 3008.1.1 AS/NZS 3000 IEC 60364 BS 7671 |
Free | 1 | Awaiting release |
Mechanical calculations
| Tool | What it does | Access | Cost | Available |
|---|---|---|---|---|
fe_calc_conveyorBelt conveyor sizing — ISO 5048, DIN 22101, CEMA Worked examples |
Preliminary belt conveyor design: belt width for the capacity, belt and material loads, rolling and lift resistance, drive power with service factor and drive-train efficiency for the loaded and the empty belt (declines: motoring or regenerative, flagged with the braking power to absorb), standard motor, belt tensions from the drive wrap, gearbox ratio and take-up travel and force.
ISO 5048 DIN 22101 CEMA Belt Conveyors for Bulk Materials |
Free | 1 | Awaiting release |
fe_calc_heat_loadSwitchroom heat load and AC sizing Worked examples |
Estimates the cooling load of a switchroom or electrical equipment room — equipment losses, fabric conduction, solar gain, lighting, occupants and infiltration (sensible and latent) — adds a safety margin and counts the AC units needed, with optional standby units. | Free | 1 | Awaiting release |
fe_calc_pumpPump head and suction (NPSH / NPIP) check — ANSI/HI 9.6.1 Worked examples |
Pump system hydraulics for a given duty.
ANSI/HI 9.6.1 ANSI/HI 6.6 |
Free | 1 | Awaiting release |
Utilities
| Tool | What it does | Access | Cost | Available |
|---|---|---|---|---|
fe_util_conductor_sizeConductor size equivalence (AWG / kcmil / mm²) |
Gives the cross-sectional area of an AWG, kcmil or metric conductor and the nearest standard size at or above it in the other system — e.g.
IEC 60228 ASTM B258 |
Free | 1 | Yes |
fe_util_convertUnit conversion |
Converts a value between engineering units (length, area incl. | Free | 1 | Yes |
fe_util_per_unitPer-unit and impedance base conversions |
Per-unit arithmetic for three-phase systems: base impedance/current, ohm ↔ per unit, change of base, and a transformer's %Z on its rating to ohms referred to either winding. | Free | 1 | Yes |
Reference
| Tool | What it does | Access | Cost | Available |
|---|---|---|---|---|
fe_ref_standardsStandards index |
Lists the standards and editions the fast.engineer calculation tools implement, and which tool uses each. | Free | 1 | Yes |
fe_ref_validationValidation scorecard |
Reports how each calculation tool fared against the worked-example validation corpus in the latest published run: cases, passed, failed and skipped (licensed standards data not installed), with the build and corpus version, and whether that run matches the build answering now. | Free | 1 | Yes |
Your calculations
| Tool | What it does | Access | Cost | Available |
|---|---|---|---|---|
fe_account_file_deleteDelete a stored file |
Deletes one file (and its bytes) from your account file store.
Replaces data |
Signed in or agent keyaccount |
1 | Yes |
fe_account_file_download_urlGet a link to download a stored file |
Returns a signed URL (valid 15 minutes) to download one file from your account file store. | Signed in or agent keyaccount |
1 | Yes |
fe_account_file_listList my stored files |
Lists the files in your account file store, newest first, with ids for fe_account_file_download_url and fe_account_file_delete, and your storage use. | Signed in or agent keyaccount |
1 | Yes |
fe_account_file_upload_urlGet a link to upload a file to my file store Worked example |
Creates an empty file in your account file store and returns a signed, single-use URL: PUT the file's bytes to it (e.g.
Changes data |
Signed in or agent keyaccount |
1 | Yes |
fe_agent_claimKeep this agent's data: send a claim link to an email |
Agent keys only.
Changes data |
Signed in or agent keyaccount |
1 | Yes |
fe_calc_getRead a saved calculation |
Reads one calculation from your fast.engineer calcs library: its saved inputs and results, the tool arguments and provenance hashes if it was saved through fe_calc_save, and links to the web page, print-ready report and Excel export. | Signed in or agent keyaccount |
1 | Yes |
fe_calc_listList my saved calculations |
Lists the calculations saved in your fast.engineer calcs library (from the website or fe_calc_save), newest first, with ids for fe_calc_get. | Signed in or agent keyaccount |
1 | Yes |
fe_calc_saveSave a calculation to my library |
Saves the result of a free calculation tool (fe_calc_*) to your fast.engineer calcs library: the calculation is re-run with the same inputs, stored with your title, calc number and tag, and returned with links to the web page, the print-ready report and the Excel export.
Changes data |
Signed in or agent keyaccount |
2 | Yes |
Saved networks (PSAS)
| Tool | What it does | Access | Cost | Available |
|---|---|---|---|---|
fe_network_coordinateGrade overcurrent relays on a saved network |
Grades and optionally optimises the inverse-time overcurrent relays (devices with relay_enabled) on one of your saved radial networks: pickups above 1.25 × maximum load and checked for sensitivity against the IEC 60909 minimum fault, time dials graded from the most downstream relay upwards with the required margin at the maximum through-fault, and a selectivity report per relay pair.
IEC 60255-151 IEC 60909-0 Replaces data |
Signed in or agent keyaccount |
5 | Yes |
fe_network_createCreate a saved network |
Creates a new power-system network in your fast.engineer account, optionally populated in one step with the same ops fe_network_edit takes (buses first, then lines/transformers, sources, machines, devices).
Changes data |
Signed in or agent keyaccount |
1 | Yes |
fe_network_editEdit a saved network |
Changes one of your saved networks with a list of ops applied in order, all-or-nothing: add_/update_/remove_ bus, line (overhead line or cable), transformer, machine, source (utility infeed) and device (breaker/fuse, optionally an overcurrent relay), and set_study_settings.
Replaces data |
Signed in or agent keyaccount |
2 | Yes |
fe_network_getRead a saved network |
Reads one of your saved networks: a summary (settings, element counts, recent study runs) or the full list of buses, lines, transformers, machines, utility sources or protective devices. | Signed in or agent keyaccount |
1 | Yes |
fe_network_listList my saved networks |
Lists the power-system networks saved in your fast.engineer account (PSAS), newest first, with ids to use in the other fe_network_* tools. | Signed in or agent keyaccount |
1 | Yes |
fe_network_studyStudy a saved network |
Runs a study on one of your saved networks and records it in the network's run history: load_flow (bus voltages, branch flows and loading, losses), fault (IEC 60909 max/min three-phase, line-to-ground, line-to-line or line-to-line-to-ground fault at a bus with breaking/making duty checks of the devices there — pandapower; or a classical Z-bus/MVA three-phase fault — native), contingency (N-1 line/transformer outages), thevenin (driving-point impedance at a bus) or diagnose (data and topology problems).
IEC 60909-0 Changes data |
Signed in or agent keyaccount |
3 | Yes |
Team projects
| Tool | What it does | Access | Cost | Available |
|---|---|---|---|---|
fe_file_upload_urlGet a file upload link Worked example |
Returns a one-time HTTPS link to upload a load list (.xlsx or .csv), a PDF, or a drawing (.pdf, .dxf, .dwg, .png, .jpg, .tif) into a project: PUT the raw file bytes to upload_url within 15 minutes (max 25 MB), then pass file_id to fe_loadlist_import_preview or fe_drawing_digitize.
Changes data |
Team workspaceproject:write |
1 | Yes |
fe_job_cancelCancel a job |
Cancels a queued or running study job; a running job stops at its next checkpoint and keeps no results.
Replaces data |
Team workspaceproject:write |
1 | Yes |
fe_job_getJob status and summary |
Status, progress and the exceptions-first summary of a study job (e.g. | Team workspaceproject:read |
1 | Yes |
fe_loadlist_import_commitCommit a load-list import |
Writes a previewed load-list import into its draft revision: creates or updates loads (matched by tag), a supply cable per new load (cable number from the list or 'C-<tag>'), and missing boards.
Replaces data |
Team workspaceproject:write |
1 | Yes |
fe_loadlist_import_previewPreview a load-list import |
Reads an uploaded load list (.xlsx/.csv, ≤20,000 rows) or the project's load design list and shows, without changing the model, how it would import: the column → field mapping with a confidence per column, unmapped headers, row problems, boards that exist or would be created, and sample rows.
Changes data Interactive view |
Team workspaceproject:write |
1 | Yes |
fe_model_createCreate a network model |
Creates a new electrical network model in a project with its first draft revision 'A' and its design basis (standard and edition, voltage-drop budget, ambient conditions, default cable installation, demand method, growth and spare).
Changes data |
Team workspaceproject:write |
1 | Yes |
fe_model_editEdit a network model |
Adds, updates or deletes elements of a draft revision in one all-or-nothing batch: buses, sources (grid or generator), transformers, loads, cables, protective devices and fault scenarios.
Replaces data |
Team workspaceproject:write |
1 | Yes |
fe_model_getRead a network model revision |
Reads one revision of a network model: view='summary' gives the design basis and element counts; the other views page through buses, sources, transformers, loads, cables, protective devices or scenarios with every editable field (references shown by tag), as fe_model_edit expects them. | Team workspaceproject:read |
1 | Yes |
fe_model_listList network models |
Lists a project's network models and their revisions (label, status, parent) with the revision ids the other tools take. | Team workspaceproject:read |
1 | Yes |
fe_project_listList projects |
Lists the projects in this team workspace that you can open, with your access (read or write) and how many network models each holds. | Team workspaceproject:read |
1 | Yes |
fe_qa_checkModel QA |
Checks a revision without running studies: sources and connectivity, loops and multiple feeds, voltage mismatches, missing data, duplicate tags and cable numbers, transformer overload against design demand, spare ways, single-phase imbalance, unprotected cables, and (after a sizing run) cumulative voltage drop over budget. | Team workspaceproject:read |
1 | Yes |
fe_report_generateGenerate the calculation report |
Renders a revision's calculation report as PDF — revision history, design basis, exceptions first, maximum demand, fault levels, cable schedule with governing checks, assumptions, clause references, engine build and an unsigned sign-off block — and returns a 15-minute download link.
Changes data |
Team workspaceproject:write |
1 | Yes |
fe_results_getStudy results by element |
Pages through a finished job's per-element results (failures first): pass/fail, governing check, headline values, and optionally each element's full provenance envelope (checks with limits, clause references, assumptions, hashes). Interactive view | Team workspaceproject:read |
1 | Yes |
fe_revision_createCreate a revision |
Branches a new draft revision from an existing one (any status): every element is copied with the same uid, so fe_revision_diff shows exactly what changes afterwards.
Changes data |
Team workspaceproject:write |
1 | Yes |
fe_revision_diffCompare revisions |
Change register between two revisions of the same model: elements added, removed and modified (field by field, references by tag) and design-basis changes, matched by each element's stable uid. | Team workspaceproject:read |
1 | Yes |
fe_revision_set_statusSet revision status |
Moves a revision through draft → checked → approved → issued (checked may return to draft).
Replaces data |
Team workspaceproject:write |
1 | Yes |
fe_schedule_exportExport the cable schedule |
Exports a revision's cable schedule as .xlsx or .csv (cable number, route, size, earth, installation, design current, capacity, voltage drop, status and governing check, run id and result hash per line) and returns a 15-minute download link.
Changes data |
Team workspaceproject:write |
1 | Yes |
fe_study_faultFault level study |
IEC 60909 fault levels at every bus and load terminal of a revision: Ik'' max and ip, Ik'' min, earth-fault Ik1 min and the loop impedance Zs, checked against busbar ratings and cross-checked by the MVA method.
Changes data |
Team workspaceproject:write |
1 | Yes |
fe_study_max_demandMaximum demand study |
Maximum demand of every board in a revision by the duty/standby + load-factor method: running kW/kVAr per load, diversity per board compounding up the supply tree, growth and spare on each board's design demand, and transformer loading against design demand.
Changes data |
Team workspaceproject:write |
1 | Yes |
fe_study_protectionProtection check |
Checks every protective device of a revision: Ib ≤ In ≤ Iz, breaking capacity Icu ≥ Ik''max, adiabatic withstand of the cable and earth-fault loop impedance against the magnetic trip current.
Changes data |
Team workspaceproject:write |
1 | Yes |
fe_study_size_cablesSize all cables |
Sizes (or checks) every cable of a revision with the fe_calc_cable_size engine, top-down: design currents from maximum demand, Ik''max and Zs from a fault study re-solved with the new sizes until they stop changing (≤3 times), a voltage-drop limit from the revision budget.
Replaces data |
Team workspaceproject:write |
1 | Yes |
Drawings
| Tool | What it does | Access | Cost | Available |
|---|---|---|---|---|
fe_block_createCreate a library block Worked example |
Draws a new library block (symbol) from primitives — lines, polylines, rectangles, circles, arcs and texts — plus named connection nodes, and files it in a library under a style.
Changes data |
Team workspaceproject:write |
1 | Yes |
fe_block_getRead a library block Worked example |
Reads one library block by id: its symbol name, library, sub-category, style, size, connection nodes, whether it is ready for use / a draft, and (unless include_document is false) its drawing document — the shapes front_diagram renders, in block coordinates (format 'block-coordinates': y UP from the block's bottom-left corner). | Team workspaceproject:read |
1 | Yes |
fe_block_listList library blocks Worked example |
Lists the workspace's symbol libraries and the blocks a block diagram can place: active, ready-for-use blocks (drafts and archived blocks are hidden; fe_block_get still reads them by id), with each block's style, size and connection nodes (label, position as a fraction of the block from its top-left, side it faces). | Team workspaceproject:read |
1 | Yes |
fe_diagram_createCreate a block diagram Worked example |
Builds a new block diagram in a project from library blocks (fe_block_list), plain rectangles and text notes, wired together, and returns its editor link with the new shape and connection ids.
Changes data |
Team workspaceproject:write |
2 | Yes |
fe_diagram_editEdit a block diagram Worked example |
Changes a block diagram in one all-or-nothing batch, the way the editor does: only the diagram document is saved, its database rows are not updated (the same as an editor save).
Replaces data |
Team workspaceproject:write |
1 | Yes |
fe_diagram_exportExport a block diagram Worked example |
Exports a block diagram through the server's QCAD pipeline as DWG, DXF, PDF, SVG or PNG and returns a download link valid for 15 minutes; each export also records a published revision of the diagram.
Changes data |
Team workspaceproject:write |
3 | Yes |
fe_diagram_getRead a block diagram Worked example |
Reads a block diagram as the editor last saved it: every shape (id, type, library block id and name for symbols, text, top-left x,y, width, height, rotation) and every connection as from_node/to_node '<shape_id>.<node label>' with its style and title. | Team workspaceproject:read |
1 | Yes |
fe_diagram_listList block diagrams Worked example |
Lists a project's block diagrams (front_diagram documents), newest first: style, paper size, shape and connection counts, the editor link, and from_sheet_id when the diagram was digitized from a drawing sheet. | Team workspaceproject:read |
1 | Yes |
fe_drawing_digitizeDigitize a drawing Worked example |
Starts digitizing an uploaded drawing (get file_id from fe_file_upload_url: PDF, PNG/JPG/TIFF scan, or DXF/DWG): creates a drawing batch, splits it into one sheet per page and, with auto_process, runs the whole pipeline — geometry, OCR, border and title block, shapes/tables/dashed lines, symbol matching, wiring and a block diagram you can open in the editor.
Changes data |
Team workspaceproject:write |
3 | Yes |
fe_drawing_geometry_getRead sheet geometry Worked example |
Pages through a sheet's vector primitives — lines, polylines, rectangles, circles, arcs, curves and text spans — optionally only some kinds, only those overlapping a bbox, and either the live geometry or the snapshot taken after one pipeline stage (stage_key). | Team workspaceproject:read |
1 | Yes |
fe_drawing_processStart or resume drawing processing Worked example |
Starts or resumes a drawing batch's pipeline once its pages are split: after fe_drawing_digitize with auto_process=false, after fe_drawing_stop, or after a failure.
Changes data |
Team workspaceproject:write |
2 | Yes |
fe_drawing_review_decideAnswer connection review Worked example |
Answers connection-review questions with option keys from fe_drawing_review_issues (all or none) and, once nothing is left undecided, continues the pipeline to build the block diagram — re-tracing the wiring first if an answer rotated or removed a symbol.
Changes data |
Team workspaceproject:write |
1 | Yes |
fe_drawing_review_issuesConnection review questions Worked example |
Lists the questions a sheet's connection review raised before its block diagram is built — weak wire links, symbols whose rotation is ambiguous, overlapping symbols and weak symbol matches — each with its facts, whether it is decided, and the closed list of options to answer it with (fe_drawing_review_decide), plus a link to the review page. | Team workspaceproject:read |
1 | Yes |
fe_drawing_sheet_exportExport a sheet Worked example |
Exports one sheet as a file and returns a 15-minute download link: svg or png renders the sheet's vector geometry (the live geometry or the snapshot after one stage, optionally only a bbox); source_pdf is the sheet's original PDF page.
Changes data |
Team workspaceproject:write |
2 | Yes |
fe_drawing_sheet_getRead a digitized sheet Worked example |
Reads one section of a digitized sheet: summary (primitive counts, bounds, symbol and connection counts, block diagram, AI-review verdict), titleblock (fields read from the title block), symbols (matched library symbols with box, rotation, score, text read inside them and every pin with its traced link), connections (the reviewed wire links between pins), detections (classified shapes, tables, dashed lines, revision clouds, fills, wire ends), review (the ai_review debrief, a Gemini review of the finished diagram on the batch creator's key) or log (processing log). | Team workspaceproject:read |
1 | Yes |
fe_drawing_statusDrawing batch status Worked example |
Reports a drawing batch's progress: a headline, the overall phase, and per sheet its phase (failed, awaiting_review, waiting_source, running, queued, stopped, done, idle), the stage it is on, every pipeline stage's state and message, the block diagram id with an editor link once built, and the connection-review count when a sheet waits for decisions. | Team workspaceproject:read |
1 | Yes |
fe_drawing_stopStop a drawing batch Worked example |
Stops all processing of a drawing batch: revokes its queued and running pipeline tasks and marks the running stages stopped (a pause, not a failure).
Replaces data |
Team workspaceproject:write |
1 | Yes |
fe_drawing_symbol_setsList symbol libraries Worked example |
Lists the symbol libraries (symbol sets) a project's drawings can be matched against — the project's own and the team-shared ones — with how many active symbols each holds and how many can match vector geometry (PDF/DXF) or raster crops (scans). | Team workspaceproject:read |
1 | Yes |
Sign-off marketplace
| Tool | What it does | Access | Cost | Available |
|---|---|---|---|---|
fe_market_certification_getGet the signed certification |
Returns a certified sign-off request's signed documents: for each certification artefact (e.g. | Signed in or agent keymarketplace |
1 | Awaiting release |
fe_market_change_request_respondResubmit after a change request |
Answers the reviewer's change request on a sign-off request: once the revised documents have been added (fe_market_document_add — at least one is required), it relocks the bundle as the next version with a new SHA-256, resolves the open change requests and puts the review back in progress; the reviewer re-confirms the checklist items against the new version.
Changes data |
Signed in or agent keymarketplace |
1 | Awaiting release |
fe_market_document_addAdd a document to a sign-off bundle Worked example |
Copies a file from your account file store into a sign-off request's review bundle, with its kind and whether an AI tool produced it (and which tool/model).
Changes data |
Signed in or agent keymarketplace |
1 | Awaiting release |
fe_market_engineer_searchFind eligible sign-off reviewers Worked example |
Lists registered engineers who could sign off a project today: each holds a registration the state's scheme accepts for the discipline (checked on the public register recently), professional indemnity insurance in force, approved identity, and is taking work. | Signed in or agent keymarketplace |
1 | Awaiting release |
fe_market_estimate_acceptAccept a quote |
Accepts one quote on your sign-off request and confirms its scope for the client: the other quotes are declined, a single-milestone agreement for the full fee is created and the engineer is asked to confirm it (their eligibility is re-checked).
Changes data |
Signed in or agent keymarketplace |
2 | Awaiting release |
fe_market_estimates_listRead quotes on a sign-off request |
Lists the quotes (estimates) registered engineers have submitted on one of your sign-off requests: total fee and review fee in AUD (the review fee is what the engineer keeps if they reject the bundle outright), proposed timeline, assumptions, exclusions and qualifications, and an anonymised summary of the engineer with their public register entries. | Signed in or agent keymarketplace |
1 | Awaiting release |
fe_market_request_statusSign-off request status Worked example |
Reports where a sign-off request stands and the one next step: the job status, the bundle (version, lock hash, missing document kinds), how many quotes have been submitted, the agreement and contract once a quote is accepted, the review's status (awaiting_funds comes with funding_url — the escrow page a person must use), open change requests from the reviewer, and whether the certification is ready. | Signed in or agent keymarketplace |
1 | Awaiting release |
fe_market_request_submitSubmit a sign-off request Worked example |
Checks a draft sign-off request's bundle (every required document kind present, AI declaration consistent with the documents), locks it — freezing its SHA-256 so the reviewer certifies exactly these files — and opens the request to eligible registered engineers, who are notified and can quote.
Changes data |
Signed in or agent keymarketplace |
2 | Awaiting release |
fe_market_requests_listList my sign-off requests Worked example |
Lists the account's sign-off requests, newest first, with id, title, state, discipline, status, when and through which channel (web or mcp) each was created — whether posted by an agent or on the website. | Signed in or agent keymarketplace |
1 | Awaiting release |
fe_market_review_request_createCreate a sign-off request Worked example |
Creates a draft request for a registered Australian engineer to review and certify documents (one discipline per request), on behalf of the signed-in account, with its AI-use declaration — say truthfully whether AI tools prepared the documents, which ones, and what a person checked; it is recorded in the certification.
Changes data |
Signed in or agent keymarketplace |
2 | Awaiting release |
fe_market_schemesAustralian sign-off schemes Worked example |
Explains which engineering registration a sign-off needs in an Australian state: the registration scheme (RPEQ, NSW DBP, VIC PER, ACT PER, WA building engineer or the national NER), whether it is mandatory yet, the accepted registration types and levels, the certification artefact issued (e.g. | Free | 1 | Awaiting release |
Choosing between similar tools
| You want | Use |
|---|---|
| Select or verify one cable | fe_calc_cable_size (sizing_mode auto or check) |
| Voltage drop of a known cable or a lighting run, or the longest motor run within a limit | fe_calc_voltage_drop |
| Fault level along one radial path | fe_calc_short_circuit with mode='point_to_point' |
| Fault levels on a small network you describe inline | fe_calc_short_circuit with mode='network' |
| Studies on a network you keep | fe_network_study on a saved PSAS network |
| Size every cable on a project | fe_study_size_cables on a team model |
| A transformer's own terminal fault level | fe_calc_transformer |
| Any unit or per-unit conversion | fe_util_convert, fe_util_conductor_size, fe_util_per_unit |
| Turn an uploaded drawing into symbols, wiring and a block diagram | fe_drawing_digitize, then poll fe_drawing_status |
| Get a stopped, failed or idle digitization moving again | fe_drawing_process (continue); answering its review questions is fe_drawing_review_decide |
| The digitized geometry itself (lines, text, circles) | fe_drawing_geometry_get; matched symbols and wires are fe_drawing_sheet_get |
| Draw a block diagram from library symbols | fe_diagram_create, corrections with fe_diagram_edit, CAD files with fe_diagram_export |
| A symbol the library lacks | fe_block_create (workspace-wide; check fe_block_list first) |
Common inputs
- Units are SI unless a field says otherwise: lengths in metres (cable route length is one way), currents in A, power in kW, voltages line-to-line in V, temperatures in °C. NEC and CEC conductor sizes use AWG/kcmil.
- Every calculation tool takes
response_format:concise(default — results, checks and provenance) ordetailed(also every intermediate value, such as the table values looked up). - Choices are fixed lists (for example the installation method of a cable), so an assistant cannot invent an unsupported option. A wrong input comes back as an error naming the field and how to fix it.