Overview
Designs belt conveyors from first principles per ISO 5048, DIN 22101, and CEMA methodology. Given material properties, conveyor geometry, and operating parameters, the calculator determines belt width, tensions, drive power, motor size, gearbox ratio, and take-up requirements.
Key capabilities:
- Automatic belt width selection from standard sizes (300–2400 mm) based on required cross-sectional area and troughing angle
- ISO 5048 / DIN 22101 motional resistances: main resistance on both strands (idlers, belt and material at the design capacity), secondary resistances via the length coefficient \(C\), lift on the material and user special resistances
- Belt tension analysis using the Eytelwein (capstan) equation
- Motor sizing with service factor and drive-train efficiency, rounded to standard IEC motor ratings
- Gearbox ratio and drum torque computation
- Take-up travel and force estimation
- Automatic warnings for steep inclinations, high belt tensions, low capacity margins, and motor loading
Input Parameters
Material & Capacity
| Parameter | Type | Default | Range | Description |
|---|---|---|---|---|
capacity_tph |
Number | 200 | 1 – 10 000 t/h | Required conveyor capacity (tonnes per hour) |
bulk_density |
Number | 1600 | 100 – 5000 kg/m³ | Bulk density of conveyed material |
material_name |
String | General aggregate | — | Material type name (documentation only) |
Conveyor Geometry
| Parameter | Type | Default | Range | Description |
|---|---|---|---|---|
conveyor_length |
Number | 120 | 5 – 2000 m | Total conveyor length (horizontal projection or actual) |
inclination_angle |
Number | 0 | −25 – +30° | Inclination angle (positive = upward, negative = downward) |
Belt Parameters
| Parameter | Type | Default | Range | Description |
|---|---|---|---|---|
belt_speed |
Number | 3.0 | 0.5 – 8 m/s | Belt linear speed |
troughing_angle |
Enum: 20 / 30 / 35 / 45 | 35 | — | Idler troughing angle (°) |
belt_width_mm |
Number | 0 | 0+ mm | Belt width override (0 = auto-calculate from capacity) |
belt_mass_per_m |
Number | 0 | 0 – 50 kg/m | Belt linear mass (0 = estimate from width at 15 kg/m per m of width) |
idler_mass_carry_per_m |
Number | 0 | 0 – 150 kg/m | Carrying idler rotating mass per metre \(q_{RO}\) = set mass / pitch (0 = estimate from width) |
idler_mass_return_per_m |
Number | 0 | 0 – 100 kg/m | Return idler rotating mass per metre \(q_{RU}\) = set mass / pitch (0 = estimate from width) |
Resistance & Friction
| Parameter | Type | Default | Range | Description |
|---|---|---|---|---|
rolling_resistance_coeff |
Number | 0.02 | 0.01 – 0.05 | Artificial friction factor \(f\) (ISO 5048 / DIN 22101): 0.02 typical, 0.025–0.03 harsh, 0.012–0.016 for braked declines |
belt_pulley_friction |
Number | 0.30 | 0.2 – 0.5 | Belt-to-pulley friction coefficient (with lagging) |
Drive Parameters
| Parameter | Type | Default | Range | Description |
|---|---|---|---|---|
drive_drum_diameter |
Number | 0.5 | 0.1 – 2.0 m | Drive drum diameter |
wrap_angle |
Number | 210 | 120 – 240° | Belt wrap angle on drive drum |
motor_speed_rpm |
Number | 1450 | 500 – 3000 rpm | Motor nominal speed |
Efficiency & Service Factors
| Parameter | Type | Default | Range | Description |
|---|---|---|---|---|
service_factor |
Number | 1.3 | 1.0 – 2.0 | Service factor (1.2–1.6 typical) |
gearbox_efficiency |
Number | 0.95 | 0.8 – 1.0 | Gearbox mechanical efficiency |
coupling_efficiency |
Number | 0.99 | 0.9 – 1.0 | Coupling efficiency |
motor_efficiency |
Number | 0.95 | 0.8 – 0.98 | Motor efficiency |
Additional Resistances & Options
| Parameter | Type | Default | Range | Description |
|---|---|---|---|---|
additional_resistance_n |
Number | 0 | 0 – 50 000 N | Special resistances \(F_S\): belt scrapers, ploughs, skirtboards beyond the feed zone, tilted idlers (secondary resistances are already included via \(C\)) |
impact_factor |
Number | 1.0 | 1.0 – 1.5 | Impact factor for loading (1.0–1.3 for high impact) |
auto_select_belt_width |
Boolean | true | — | Automatically select standard belt width from capacity |
use_standard_motor |
Boolean | true | — | Round up to next standard IEC motor size |
calculate_take_up |
Boolean | true | — | Calculate take-up travel and force requirements |
Output Results
| Output | Unit | Description |
|---|---|---|
area_required_m2 |
m² | Required belt cross-sectional area from capacity |
belt_width_mm |
mm | Selected belt width (standard or user-specified) |
belt_width_m |
m | Belt width in metres |
area_actual_m2 |
m² | Actual cross-sectional area provided by selected belt |
capacity_actual_tph |
t/h | Actual capacity achievable with selected belt |
troughing_factor_k |
— | Troughing factor \(K(\theta)\) used |
material_linear_mass_kg_per_m |
kg/m | Material load at the design capacity, \(q_G = Q/(3.6\,v)\) |
belt_linear_mass_kg_per_m |
kg/m | Belt linear mass (specified or estimated) |
idler_mass_carry_kg_per_m / idler_mass_return_kg_per_m |
kg/m | Idler rotating mass \(q_{RO}\) / \(q_{RU}\) (specified or estimated; idler_mass_estimated lists which) |
main_resistance_n |
N | Main resistance \(F_H\), loaded belt |
length_coefficient_c |
— | Coefficient \(C\) at the conveyor length |
secondary_resistance_n |
N | Secondary resistances \(F_N = (C-1) F_H\), loaded belt |
lift_resistance_total_n |
N | Gradient (lift) resistance \(F_{St}\), signed (zero if horizontal) |
total_traction_force_n |
N | Loaded-belt traction force at the drive drum, signed (negative = regenerative) |
empty_traction_force_n |
N | Empty-belt traction force, signed |
design_traction_force_n |
N | Largest |traction force| of the loaded and empty cases (basis for tensions, torque, take-up);
tension_load_case names the case |
power_at_drum_kw / empty_power_at_drum_kw |
kW | Drum power, loaded / empty, signed |
loaded_drive_mode / empty_drive_mode |
— | motoring or regenerative |
loaded_motor_power_required_kw / empty_motor_power_required_kw |
kW | Motor requirement of each case |
governing_load_case |
— | Case that sets the motor (loaded or empty) |
regenerative / regenerative_power_kw |
— / kW | Whether either case overhauls the drive, and the braking power fed back through the motor (\(|P_{\text{drum}}| \times \eta\), no service factor) |
power_design_kw |
kW | Governing |drum power| including service factor |
combined_efficiency |
— | Combined drive-train efficiency \(\eta_{gb} \times \eta_{c} \times \eta_{m}\) |
motor_power_required_kw |
kW | Calculated motor power requirement |
motor_power_kw |
kW | Selected motor power (standard or exact) |
tight_side_tension_n |
N | Tight-side belt tension \(T_1\) |
slack_side_tension_n |
N | Slack-side belt tension \(T_2\) |
e_mu_alpha |
— | Eytelwein ratio \(e^{\mu \cdot \alpha}\) |
tension_per_mm_width_n |
N/mm | Tight-side tension per mm of belt width |
drum_torque_nm |
N·m | Torque at drive drum |
drum_speed_rpm |
rpm | Drive drum rotational speed |
gearbox_ratio |
— | Required gearbox reduction ratio |
take_up_travel_m |
m | Recommended take-up travel (min 0.15 m) |
take_up_force_n |
N | Required take-up counterweight force |
capacity_margin_percent |
% | Capacity margin of selected belt over required capacity |
motor_loading_percent |
% | Motor loading as percentage of selected motor rating |
Formulas
Cross-Sectional Area from Capacity
Solving for required area:
\[ A = \frac{Q}{\rho \cdot v \cdot 3600} \]Where \(Q\) is capacity in t/h, \(\rho\) is bulk density in t/m³, \(v\) is belt speed in m/s, and \(A\) is the material cross-sectional area on the belt.
Belt Width Selection
Solving for belt width:
\[ B = \sqrt{\frac{A}{K(\theta)}} \]Where \(K(\theta)\) is the troughing factor for idler angle \(\theta\), and \(B\) is the belt width in metres. The calculated width is rounded up to the next standard belt size.
Troughing Factors
| Troughing Angle (°) | \(K(\theta)\) |
|---|---|
| 20 | 0.143 |
| 30 | 0.175 |
| 35 | 0.197 |
| 45 | 0.245 |
Linear Masses
Material load at the design capacity (ISO 5048 / DIN 22101):
\[ q_G = \frac{Q}{3.6 \, v} \quad (\text{kg/m}) \]The belt carries the design tonnage, not a struck-full trough: the troughed area \(K(\theta) B^2\) only sets the belt width and the capacity check.
Belt mass is either user-specified or estimated as:
\[ q_B \approx B \times 15 \quad (\text{kg/m}) \]Idler rotating mass per metre, carrying and return strands:
\[ q_{RO} = \frac{m_{\text{set,carry}}}{a_0}, \qquad q_{RU} = \frac{m_{\text{set,return}}}{a_u} \]When not given they are estimated from typical idler sets for the belt width (Rulmeca design guide Tab. 11, lightest roller listed) at \(a_0 = 1.2\) m and \(a_u = 3.0\) m pitch.
Main Resistance
Where \(f\) is the artificial friction factor, \(L\) the conveyor length, \(g = 9.81\) m/s² and \(\delta\) the inclination. The belt term counts both strands; the material only the carrying strand.
Secondary Resistances — Coefficient \(C\)
Feed-zone acceleration and skirt friction, pulley bearings and belt bending around the pulleys. \(C\) from DIN 22101 Table 5 (linear interpolation; constant 1.05 from 2000 m):
| L (m) | 80 | 100 | 150 | 200 | 300 | 400 | 500 | 600 | 700 | 800 | 900 | 1000 | 1500 | ≥2000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| C | 1.92 | 1.78 | 1.58 | 1.45 | 1.31 | 1.25 | 1.20 | 1.17 | 1.14 | 1.12 | 1.10 | 1.09 | 1.06 | 1.05 |
DIN 22101 and ISO 5048 permit this method from 80 m with one feed point. Below 80 m the calculator uses the Rulmeca design-guide values (10 m: 4.5, 20 m: 3.2, 30 m: 2.6, 40 m: 2.2, 50 m: 2.1, 60 m: 2.0) and warns that the secondary resistances should be itemised.
Lift Resistance (Inclined Conveyors)
Positive for uphill, negative for downhill (the material helps drive the belt and, on a steep enough decline, overhauls the drive — see Regenerative Declines below).
Note: Only material mass contributes to net lift resistance. Belt mass cancels between the carrying side (going up) and the return side (coming back down) per DIN 22101.
Total Traction Force — Loaded and Empty Belt
Loaded belt (signed; negative means the belt overhauls the drive):
\[ F_{\text{total}} = \bigl(F_H + F_N + F_{St} + F_S\bigr) \times k_{\text{impact}} \]Empty belt (no material term, no lift, no loading impact):
\[ F_{\text{empty}} = C \cdot f \cdot L \cdot g \cdot \bigl[q_{RO} + q_{RU} + 2 q_B \cos\delta\bigr] + F_S \]Design effective tension for the belt tensions, drum torque and take-up:
\[ F_{\text{design}} = \max\bigl(|F_{\text{total}}|, |F_{\text{empty}}|\bigr) \]
Where \(F_S\) (additional_resistance_n) accounts for scrapers, ploughs and
skirtboards beyond the feed zone, and \(k_{\text{impact}}\) is the impact factor. CEMA (7th ed.) and DIN 22101
require the empty, loaded and part-loaded operating cases to be checked. On a single
slope the force is linear in the load fraction, so part-loaded belts lie between the
empty and full-load values and these two cases govern. On any decline with
\(C f \cos\delta + \sin\delta < 0\) the empty belt needs more motoring
force than the loaded one.
Drive Power
Power at drum periphery:
\[ P_{\text{drum}} = F_{\text{total}} \times v \quad (\text{W}) \]Design power with service factor:
\[ P_{\text{design}} = P_{\text{drum}} \times \text{SF} \]Required motor power for each load case, \(\eta = \eta_{\text{gearbox}} \times \eta_{\text{coupling}} \times \eta_{\text{motor}}\):
\[ P_{\text{motor}} = \frac{|P_{\text{drum}}| \times \text{SF}}{\eta} \quad \text{(motoring, } F \ge 0\text{)} \] \[ P_{\text{motor}} = |P_{\text{drum}}| \times \text{SF} \times \eta \quad \text{(regenerative, } F < 0\text{)} \]The larger of the loaded and empty requirements sets the motor. In regenerative operation the drive-train losses absorb part of the braking power before it reaches the motor, which runs as a generator (CEMA 7th ed., declined conveyors; DIN 22101).
Regenerative Declines
When a load case is regenerative the calculation flags it and reports the braking power fed back through the motor:
\[ P_{\text{regen}} = |P_{\text{drum}}| \times \eta \]The drive must absorb this power continuously: use a regenerative (active front end) VFD or a braking resistor, plus a fail-safe mechanical brake sized for the loaded decline, because the belt runs away on loss of power. A decline that is regenerative loaded and motoring empty needs a drive that controls torque in both directions. Regenerative power is largest with low running resistance, so re-check with a lower-bound friction factor (DIN 22101 suggests \(f \approx 0.012\)–0.016 for braked downhill conveyors). In regenerative operation the tight and slack strands swap at the drive pulley: \(T_1\) is on the strand leaving the drive, so locate the take-up at the low-tension point for that case.
Belt Tensions — Eytelwein (Capstan) Equation
The ratio of tight-side to slack-side tension around the drive drum:
\[ \frac{T_1}{T_2} = e^{\mu \cdot \alpha} \]Combined with the traction force relationship \(T_1 - T_2 = F_{\text{design}}\):
\[ T_2 = \frac{F_{\text{design}}}{e^{\mu \cdot \alpha} - 1} \] \[ T_1 = T_2 + F_{\text{design}} \]Where \(\mu\) is belt–pulley friction coefficient and \(\alpha\) is wrap angle in radians.
Drum Torque & Gearbox Ratio
The drum and gearbox torque reverse in regenerative operation; the rating uses the magnitude.
\[ n_{\text{drum}} = \frac{v}{\pi \cdot D_{\text{drum}}} \times 60 \quad (\text{rpm}) \] \[ \text{GR} = \frac{n_{\text{motor}}}{n_{\text{drum}}} \]Take-Up Requirements
Take-up travel for thermal expansion and elastic elongation:
\[ \Delta L = 0.02 \cdot L + 0.005 \cdot L = 0.025 \cdot L \quad (\text{m, min 0.15 m}) \]Take-up counterweight force:
\[ F_{\text{take\text{-}up}} = 1.5 \times T_2 \]\(T_2\) is from the design (largest \(|F|\)) load case.
Standard Belt Widths (mm)
| Available Standard Widths | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 300 | 400 | 500 | 650 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 | 2200 | 2400 |
Standard Motor Sizes (kW)
| IEC Standard Motor Ratings | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 0.75 | 1.1 | 1.5 | 2.2 | 3.0 | 4.0 | 5.5 | 7.5 | 11 | 15 |
| 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 |
| 160 | 200 | 250 | 315 | 355 | 400 | 450 | 500 | 560 | 630 |
| 710 | 800 | 900 | 1000 | — | |||||
Worked Examples
The 23 examples below are the validation cases for this calculation. Each one was produced by the calculation engine from the inputs shown, every figure was checked against the independent reference quoted at the end of the example, and the same cases are run against every engine build (see validation scorecard, tool fe_calc_conveyor; worked examples for every calculation).
| # | Case | Belt width (mm) | Te loaded / empty (N) | Drum power (kW) | Motor (kW) | Drive | Governing | Result |
|---|---|---|---|---|---|---|---|---|
| 1 | Horizontal aggregate conveyor | 300 | 1,320.9 / 579.7 | 3.963 | 7.5 | motoring | motor rating | PASS |
| 2 | 10° incline with belt width and mass given | 1,000 | 25,009.3 / 2,968.7 | 62.523 | 110 | motoring | motor rating | PASS |
| 3 | Bare pulley with 180° wrap | 400 | 8,078.9 / 775.1 | 20.197 | 30 | motoring | motor rating | PASS |
| 4 | Required motor beyond the largest standard 1000 kW | 800 | 237,700.9 / 15,192.1 | 950.804 | 1,000 | motoring | motor rating | FAIL |
| 5 | 1 000 m overland coal conveyor | 1,000 | 90,227.7 / 12,992.7 | 360.911 | 560 | motoring | motor rating | PASS |
| 6 | Steep 18° crushed-ore conveyor on 45° idlers | 500 | 37,877.0 / 918.3 | 113.631 | 200 | motoring | motor rating | PASS |
| 7 | Gentle 2° decline with scraper and skirt resistance | 500 | 1,828.2 / 1,767.6 | 2.742 | 4 | motoring | motor rating | PASS |
| 8 | Fast 6 m/s belt for wood chips | 400 | 2,240.5 / 1,348.1 | 13.443 | 22 | motoring | belt capacity | PASS |
| 9 | Short grain conveyor with 30° idlers | 300 | 327.9 / 221.6 | 0.656 | 1.1 | motoring | motor rating | PASS |
| 10 | Heavy-duty service factor 1.5 and f = 0.03 | 400 | 11,750.3 / 1,387.5 | 29.376 | 55 | motoring | motor rating | PASS |
| 11 | Impact factor 1.3 at a loading point | 500 | 21,291.1 / 763.7 | 42.582 | 75 | motoring | belt capacity | PASS |
| 12 | Inclined iron ore conveyor at 15° | 500 | 32,400.9 / 1,136.4 | 81.002 | 132 | motoring | motor rating | PASS |
| 13 | Lagged pulley with snub, 240° wrap | 400 | 8,078.9 / 775.1 | 20.197 | 30 | motoring | motor rating | PASS |
| 14 | Mild 3.5° decline: regenerative loaded, motoring empty | 650 | −2,762.5 / 10,732.7 | −6.906 | 45 | regenerative | motor rating | PASS |
| 15 | 2-pole motor on a 315 mm drive pulley | 400 | 771.3 / 331.9 | 0.926 | 1.5 | motoring | motor rating | PASS |
| 16 | 6-pole motor on a 1.25 m drive pulley | 650 | 24,700.7 / 1,976.7 | 86.452 | 132 | motoring | motor rating | PASS |
| 17 | Published worked example: 1000 t/h, 150 m, 15 m lift | 1,000 | 24,058.9 / 1,537.5 | 55.336 | 75 | motoring | motor rating | PASS |
| 18 | Flat 20° troughing for dry sand | 400 | 1,065.6 / 411.6 | 1.598 | 3 | motoring | belt capacity | PASS |
| 19 | 5 m feeder conveyor at the take-up floor | 300 | 162.0 / 63.9 | 0.162 | 0.75 | motoring | belt capacity | PASS |
| 20 | Slow 0.5 m/s belt for dense ore | 650 | 4,341.8 / 505.0 | 2.171 | 4 | motoring | belt capacity | PASS |
| 21 | Steep 12° decline, regenerative when loaded | 500 | −31,531.2 / 4,232.9 | −78.828 | 110 | regenerative | belt capacity | PASS |
| 22 | Given 500 mm belt cannot carry 650 t/h | 500 | 3,868.2 / 715.4 | 7.736 | 15 | motoring | belt capacity | FAIL |
| 23 | Oversized 1200 mm belt for 300 t/h | 1,200 | 3,522.1 / 2,160.9 | 7.044 | 11 | motoring | motor rating | PASS |
Example 1 — Horizontal aggregate conveyor
The baseline: every input at its default, the engine selects the belt width and the motor.
Given: 200 t/h of bulk material at 1,600 kg/m³, 120 m horizontal, belt speed 3 m/s on 35° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 200 / (3.6 × 3 × 1,600) = 0.01157 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.01157 / 0.197) = 242.4 mm → next standard width 300 mm; A = K · B² = 0.197 × 0.3² = 0.01773 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 3 × 1,600 × 0.01773 = 306.4 t/h (margin 53.2 %) → 200.0 vs limit 306.4 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 200 / (3.6 × 3) = 18.519 kg/m (design capacity); qB = B × 15 = 0.3 × 15 = 4.50 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 120 × 9.81 × [4.250 + 1.233 + (2 × 4.50 + 18.519) × 1.00000] = 777.0 N |
| Secondary resistance | C(120 m) = 1.7000 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.7000 − 1) × 777.0 = 543.9 N |
| Lift resistance | FSt = 0 N (horizontal) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (777.0 + 543.9 + 0.0) = 1,320.9 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.7000 × 0.02 × 120 × 9.81 × 14.483 = 579.7 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 1,320.9 × 3 / 1000 = 3.963 kW; empty 579.7 × 3 / 1000 = 1.739 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 3.963 × 1.3 / 0.8935 = 5.766 kW; empty: motoring 1.739 × 1.3 / 0.8935 = 2.530 kW; the loaded belt governs: Pmotor = 5.766 kW |
| Motor rating | Next standard IEC rating ≥ 5.766 kW → 7.5 kW (76.9 % loaded) → 5.766 vs limit 7.500 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 1,320.9 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 1,320.9 / (3.0028 − 1) = 659.5 N; T1 = T2 + Te,d = 1,980.4 N (6.6 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 1,320.9 × 0.5/2 = 330.2 N·m; ndrum = 60 · v / (π · D) = 60 × 3 / (π × 0.5) = 114.59 rpm; i = nmotor / ndrum = 1,450 / 114.59 = 12.654 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 120) = 3.000 m; Ftake-up = 1.5 × T2 = 1.5 × 659.5 = 989.3 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 300 mm belt, Te 1,320.9 N loaded, 7.5 kW motor (loaded belt governs); governing: motor rating |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 200/(3.6 × 3 × 1600) = 0.01157 m²; B = √(0.01157/0.197) = 242.4 mm → 300 mm standard; A = 0.197 × 0.3² = 0.01773 m² → Q_max = 306.4 t/h; q_G = 200/(3.6 × 3) = 18.519 kg/m; q_B = 4.50 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(120 m) = 1.7000 (DIN 22101 Table 5); cos δ = 1.00000; LOADED F_H = 0.02 × 120 × 9.81 × 33.002 = 777.0 N, F_N = (1.7000 − 1) × 777.0 = 543.9 N, F_St = 18.519 × 9.81 × 0.000 = 0.0 N, T_e = (777.0 + 543.9 + 0.0 + 0) = 1320.9 N (motoring: |P_drum| = 3.963 kW, P_motor = 3.963 × 1.3 / 0.8935 = 5.766 kW); EMPTY T_e = 1.7000 × 0.02 × 120 × 9.81 × 14.483 + 0 = 579.7 N (motoring: |P_drum| = 1.739 kW, P_motor = 1.739 × 1.3 / 0.8935 = 2.530 kW); governing loaded → 5.766 kW → 7.5 kW standard (76.9 %); regenerative power at the motor = 0.000 kW; design |T_e| = 1320.9 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 1320.9/(3.0028 − 1) = 659.5 N; T1 = 1980.4 N; M_drum = 1320.9 × 0.5/2 = 330.2 N·m; n_drum = 60 × 3/(π × 0.5) = 114.59 rpm; i = 1450/114.59 = 12.654; take-up = max(0.15, 0.025 × 120) = 3.000 m, force 1.5 × 659.5 = 989.3 N (validation case c0026-200tph-level) |
Example 2 — 10° incline with belt width and mass given
A given 1000 mm belt and 20 kg/m belt mass on a 10° incline, where lift dominates the drive power.
Given: 500 t/h of bulk material at 1,000 kg/m³, 200 m incline 10°, belt speed 2.5 m/s on 35° idlers; belt width 1,000 mm given, belt mass 20 kg/m given. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 500 / (3.6 × 2.5 × 1,000) = 0.05556 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = 1,000 mm (given); A = K · B² = 0.197 × 1² = 0.19700 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2.5 × 1,000 × 0.19700 = 1,773.0 t/h (margin 254.6 %) → 500.0 vs limit 1,773.0 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 500 / (3.6 × 2.5) = 55.556 kg/m (design capacity); qB = 20.00 kg/m (given); qRO = 9.750, qRU = 3.033 kg/m (typical 1,000 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 200 × 9.81 × [9.750 + 3.033 + (2 × 20.00 + 55.556) × 0.98481] = 4,194.3 N |
| Secondary resistance | C(200 m) = 1.4500 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.4500 − 1) × 4,194.3 = 1,887.4 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 200 × sin(10°) = 34.730 m: 55.556 × 9.81 × 34.730 = 18,927.7 N (material only — the belt cancels between the strands) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (4,194.3 + 1,887.4 + 18,927.7) = 25,009.3 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.4500 × 0.02 × 200 × 9.81 × 52.176 = 2,968.7 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 25,009.3 × 2.5 / 1000 = 62.523 kW; empty 2,968.7 × 2.5 / 1000 = 7.422 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 62.523 × 1.3 / 0.8935 = 90.971 kW; empty: motoring 7.422 × 1.3 / 0.8935 = 10.799 kW; the loaded belt governs: Pmotor = 90.971 kW |
| Motor rating | Next standard IEC rating ≥ 90.971 kW → 110 kW (82.7 % loaded) → 90.971 vs limit 110.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 25,009.3 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 25,009.3 / (3.0028 − 1) = 12,486.9 N; T1 = T2 + Te,d = 37,496.3 N (37.5 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 25,009.3 × 0.5/2 = 6,252.3 N·m; ndrum = 60 · v / (π · D) = 60 × 2.5 / (π × 0.5) = 95.49 rpm; i = nmotor / ndrum = 1,450 / 95.49 = 15.184 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 200) = 5.000 m; Ftake-up = 1.5 × T2 = 1.5 × 12,486.9 = 18,730.4 N; Constant-tension take-up (L ≥ 200 m) |
| Result | 2/2 checks pass → PASS; 1,000 mm belt, Te 25,009.3 N loaded, 110 kW motor (loaded belt governs); governing: motor rating |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 500/(3.6 × 2.5 × 1000) = 0.05556 m²; B = 1000 mm given; A = 0.197 × 1² = 0.19700 m² → Q_max = 1773.0 t/h; q_G = 500/(3.6 × 2.5) = 55.556 kg/m; q_B = 20.00 kg/m (given); q_RO = 9.750, q_RU = 3.033 kg/m (Rulmeca Tab. 11 1000 mm sets / 1.2 m and 3.0 m pitch unless given); C(200 m) = 1.4500 (DIN 22101 Table 5); cos δ = 0.98481; LOADED F_H = 0.02 × 200 × 9.81 × 106.887 = 4194.3 N, F_N = (1.4500 − 1) × 4194.3 = 1887.4 N, F_St = 55.556 × 9.81 × 34.730 = 18927.7 N, T_e = (4194.3 + 1887.4 + 18927.7 + 0) = 25009.3 N (motoring: |P_drum| = 62.523 kW, P_motor = 62.523 × 1.3 / 0.8935 = 90.971 kW); EMPTY T_e = 1.4500 × 0.02 × 200 × 9.81 × 52.176 + 0 = 2968.7 N (motoring: |P_drum| = 7.422 kW, P_motor = 7.422 × 1.3 / 0.8935 = 10.799 kW); governing loaded → 90.971 kW → 110 kW standard (82.7 %); regenerative power at the motor = 0.000 kW; design |T_e| = 25009.3 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 25009.3/(3.0028 − 1) = 12486.9 N; T1 = 37496.3 N; M_drum = 25009.3 × 0.5/2 = 6252.3 N·m; n_drum = 60 × 2.5/(π × 0.5) = 95.49 rpm; i = 1450/95.49 = 15.184; take-up = max(0.15, 0.025 × 200) = 5.000 m, force 1.5 × 12486.9 = 18730.4 N (validation case c0026-500tph-inclined) |
Example 3 — Bare pulley with 180° wrap
A low Euler factor (μ = 0.25, θ = 180°) raises the slack-side tension and the take-up force.
Given: 350 t/h of bulk material at 1,600 kg/m³, 140 m incline 6°, belt speed 2.5 m/s on 35° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 180°, μ = 0.25, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 350 / (3.6 × 2.5 × 1,600) = 0.02431 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.02431 / 0.197) = 351.3 mm → next standard width 400 mm; A = K · B² = 0.197 × 0.4² = 0.03152 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2.5 × 1,600 × 0.03152 = 453.9 t/h (margin 29.7 %) → 350.0 vs limit 453.9 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 350 / (3.6 × 2.5) = 38.889 kg/m (design capacity); qB = B × 15 = 0.4 × 15 = 6.00 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 140 × 9.81 × [4.250 + 1.233 + (2 × 6.00 + 38.889) × 0.99452] = 1,540.8 N |
| Secondary resistance | C(140 m) = 1.6200 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.6200 − 1) × 1,540.8 = 955.3 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 140 × sin(6°) = 14.634 m: 38.889 × 9.81 × 14.634 = 5,582.9 N (material only — the belt cancels between the strands) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (1,540.8 + 955.3 + 5,582.9) = 8,078.9 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.6200 × 0.02 × 140 × 9.81 × 17.418 = 775.1 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 8,078.9 × 2.5 / 1000 = 20.197 kW; empty 775.1 × 2.5 / 1000 = 1.938 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 20.197 × 1.3 / 0.8935 = 29.387 kW; empty: motoring 1.938 × 1.3 / 0.8935 = 2.819 kW; the loaded belt governs: Pmotor = 29.387 kW |
| Motor rating | Next standard IEC rating ≥ 29.387 kW → 30 kW (98.0 % loaded) → 29.387 vs limit 30.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 8,078.9 N (loaded); eμθ = e0.25 × 180π/180 = 2.1933; T2 = Te,d / (eμθ − 1) = 8,078.9 / (2.1933 − 1) = 6,770.3 N; T1 = T2 + Te,d = 14,849.3 N (37.1 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 8,078.9 × 0.5/2 = 2,019.7 N·m; ndrum = 60 · v / (π · D) = 60 × 2.5 / (π × 0.5) = 95.49 rpm; i = nmotor / ndrum = 1,450 / 95.49 = 15.184 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 140) = 3.500 m; Ftake-up = 1.5 × T2 = 1.5 × 6,770.3 = 10,155.5 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 400 mm belt, Te 8,078.9 N loaded, 30 kW motor (loaded belt governs); governing: motor rating. Motor loading is high (98.0%). Consider next motor size up. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 350/(3.6 × 2.5 × 1600) = 0.02431 m²; B = √(0.02431/0.197) = 351.3 mm → 400 mm standard; A = 0.197 × 0.4² = 0.03152 m² → Q_max = 453.9 t/h; q_G = 350/(3.6 × 2.5) = 38.889 kg/m; q_B = 6.00 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(140 m) = 1.6200 (DIN 22101 Table 5); cos δ = 0.99452; LOADED F_H = 0.02 × 140 × 9.81 × 56.093 = 1540.8 N, F_N = (1.6200 − 1) × 1540.8 = 955.3 N, F_St = 38.889 × 9.81 × 14.634 = 5582.9 N, T_e = (1540.8 + 955.3 + 5582.9 + 0) = 8078.9 N (motoring: |P_drum| = 20.197 kW, P_motor = 20.197 × 1.3 / 0.8935 = 29.387 kW); EMPTY T_e = 1.6200 × 0.02 × 140 × 9.81 × 17.418 + 0 = 775.1 N (motoring: |P_drum| = 1.938 kW, P_motor = 1.938 × 1.3 / 0.8935 = 2.819 kW); governing loaded → 29.387 kW → 30 kW standard (98.0 %); regenerative power at the motor = 0.000 kW; design |T_e| = 8078.9 N (loaded); e^(μθ) = e^(0.25 × 180π/180) = 2.1933; T2 = 8078.9/(2.1933 − 1) = 6770.3 N; T1 = 14849.3 N; M_drum = 8078.9 × 0.5/2 = 2019.7 N·m; n_drum = 60 × 2.5/(π × 0.5) = 95.49 rpm; i = 1450/95.49 = 15.184; take-up = max(0.15, 0.025 × 140) = 3.500 m, force 1.5 × 6770.3 = 10155.5 N (validation case c0026-bare-pulley-wrap-180) |
Example 4 — Required motor beyond the largest standard 1000 kW
A 1 km, 5° overland conveyor needs more than the largest standard motor, so the motor-rating check fails.
Given: 3,000 t/h of bulk material at 1,600 kg/m³, 1,000 m incline 5°, belt speed 4 m/s on 45° idlers; belt width to be selected, belt mass 30 kg/m given. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 3,000 / (3.6 × 4 × 1,600) = 0.13021 m² |
|---|---|
| Belt width | K(45°) = 0.245; B = √(Areq / K) = √(0.13021 / 0.245) = 729.0 mm → next standard width 800 mm; A = K · B² = 0.245 × 0.8² = 0.15680 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 4 × 1,600 × 0.15680 = 3,612.7 t/h (margin 20.4 %) → 3,000.0 vs limit 3,612.7 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 3,000 / (3.6 × 4) = 208.333 kg/m (design capacity); qB = 30.00 kg/m (given); qRO = 8.667, qRU = 2.600 kg/m (typical 800 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 1,000 × 9.81 × [8.667 + 2.600 + (2 × 30.00 + 208.333) × 0.99619] = 54,657.2 N |
| Secondary resistance | C(1,000 m) = 1.0900 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.0900 − 1) × 54,657.2 = 4,919.1 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 1,000 × sin(5°) = 87.156 m: 208.333 × 9.81 × 87.156 = 178,124.5 N (material only — the belt cancels between the strands) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (54,657.2 + 4,919.1 + 178,124.5) = 237,700.9 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.0900 × 0.02 × 1,000 × 9.81 × 71.038 = 15,192.1 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 237,700.9 × 4 / 1000 = 950.804 kW; empty 15,192.1 × 4 / 1000 = 60.768 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 950.804 × 1.3 / 0.8935 = 1,383.413 kW; empty: motoring 60.768 × 1.3 / 0.8935 = 88.418 kW; the loaded belt governs: Pmotor = 1,383.413 kW |
| Motor rating | Next standard IEC rating ≥ 1,383.413 kW → 1,000 kW (138.3 % loaded) → 1,383.413 vs limit 1,000.000 kW FAIL |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 237,700.9 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 237,700.9 / (3.0028 − 1) = 118,682.1 N; T1 = T2 + Te,d = 356,383.0 N (445.5 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 237,700.9 × 0.5/2 = 59,425.2 N·m; ndrum = 60 · v / (π · D) = 60 × 4 / (π × 0.5) = 152.79 rpm; i = nmotor / ndrum = 1,450 / 152.79 = 9.490 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 1,000) = 25.000 m; Ftake-up = 1.5 × T2 = 1.5 × 118,682.1 = 178,023.2 N; Constant-tension take-up (L ≥ 200 m) |
| Result | 1/2 checks pass → FAIL; 800 mm belt, Te 237,700.9 N loaded, 1,000 kW motor (loaded belt governs); governing: motor rating. Motor loading is high (138.3%). Consider next motor size up. Belt tension is high (445.5 N/mm width). Verify with belt manufacturer's allowable working tension. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 3000/(3.6 × 4 × 1600) = 0.13021 m²; B = √(0.13021/0.245) = 729.0 mm → 800 mm standard; A = 0.245 × 0.8² = 0.15680 m² → Q_max = 3612.7 t/h; q_G = 3000/(3.6 × 4) = 208.333 kg/m; q_B = 30.00 kg/m (given); q_RO = 8.667, q_RU = 2.600 kg/m (Rulmeca Tab. 11 800 mm sets / 1.2 m and 3.0 m pitch unless given); C(1000 m) = 1.0900 (DIN 22101 Table 5); cos δ = 0.99619; LOADED F_H = 0.02 × 1000 × 9.81 × 278.579 = 54657.2 N, F_N = (1.0900 − 1) × 54657.2 = 4919.1 N, F_St = 208.333 × 9.81 × 87.156 = 178124.5 N, T_e = (54657.2 + 4919.1 + 178124.5 + 0) = 237700.9 N (motoring: |P_drum| = 950.804 kW, P_motor = 950.804 × 1.3 / 0.8935 = 1383.413 kW); EMPTY T_e = 1.0900 × 0.02 × 1000 × 9.81 × 71.038 + 0 = 15192.1 N (motoring: |P_drum| = 60.768 kW, P_motor = 60.768 × 1.3 / 0.8935 = 88.418 kW); governing loaded → 1383.413 kW → 1000 kW standard (138.3 %); regenerative power at the motor = 0.000 kW; design |T_e| = 237700.9 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 237700.9/(3.0028 − 1) = 118682.1 N; T1 = 356383.0 N; M_drum = 237700.9 × 0.5/2 = 59425.2 N·m; n_drum = 60 × 4/(π × 0.5) = 152.79 rpm; i = 1450/152.79 = 9.490; take-up = max(0.15, 0.025 × 1000) = 25.000 m, force 1.5 × 118682.1 = 178023.2 N (validation case c0026-beyond-largest-motor) |
Example 5 — 1 000 m overland coal conveyor
A long conveyor: constant-tension take-up with 25 m of travel and a 45° trough belt at 4 m/s.
Given: 2,000 t/h of coal at 850 kg/m³, 1,000 m incline 2°, belt speed 4 m/s on 45° idlers; belt width to be selected, belt mass 24 kg/m given. Friction factor f = 0.02. Drive: 1 m pulley, wrap 210°, μ = 0.3, motor 990 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 2,000 / (3.6 × 4 × 850) = 0.16340 m² |
|---|---|
| Belt width | K(45°) = 0.245; B = √(Areq / K) = √(0.16340 / 0.245) = 816.7 mm → next standard width 1,000 mm; A = K · B² = 0.245 × 1² = 0.24500 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 4 × 850 × 0.24500 = 2,998.8 t/h (margin 49.9 %) → 2,000.0 vs limit 2,998.8 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 2,000 / (3.6 × 4) = 138.889 kg/m (design capacity); qB = 24.00 kg/m (given); qRO = 9.750, qRU = 3.033 kg/m (typical 1,000 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 1,000 × 9.81 × [9.750 + 3.033 + (2 × 24.00 + 138.889) × 0.99939] = 39,153.4 N |
| Secondary resistance | C(1,000 m) = 1.0900 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.0900 − 1) × 39,153.4 = 3,523.8 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 1,000 × sin(2°) = 34.899 m: 138.889 × 9.81 × 34.899 = 47,550.6 N (material only — the belt cancels between the strands) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (39,153.4 + 3,523.8 + 47,550.6) = 90,227.7 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.0900 × 0.02 × 1,000 × 9.81 × 60.754 = 12,992.7 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 90,227.7 × 4 / 1000 = 360.911 kW; empty 12,992.7 × 4 / 1000 = 51.971 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 360.911 × 1.3 / 0.8935 = 525.123 kW; empty: motoring 51.971 × 1.3 / 0.8935 = 75.617 kW; the loaded belt governs: Pmotor = 525.123 kW |
| Motor rating | Next standard IEC rating ≥ 525.123 kW → 560 kW (93.8 % loaded) → 525.123 vs limit 560.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 90,227.7 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 90,227.7 / (3.0028 − 1) = 45,050.0 N; T1 = T2 + Te,d = 135,277.7 N (135.3 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 90,227.7 × 1/2 = 45,113.9 N·m; ndrum = 60 · v / (π · D) = 60 × 4 / (π × 1) = 76.39 rpm; i = nmotor / ndrum = 990 / 76.39 = 12.959 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 1,000) = 25.000 m; Ftake-up = 1.5 × T2 = 1.5 × 45,050.0 = 67,574.9 N; Constant-tension take-up (L ≥ 200 m) |
| Result | 2/2 checks pass → PASS; 1,000 mm belt, Te 90,227.7 N loaded, 560 kW motor (loaded belt governs); governing: motor rating. Motor loading is high (93.8%). Consider next motor size up. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 2000/(3.6 × 4 × 850) = 0.16340 m²; B = √(0.16340/0.245) = 816.7 mm → 1000 mm standard; A = 0.245 × 1² = 0.24500 m² → Q_max = 2998.8 t/h; q_G = 2000/(3.6 × 4) = 138.889 kg/m; q_B = 24.00 kg/m (given); q_RO = 9.750, q_RU = 3.033 kg/m (Rulmeca Tab. 11 1000 mm sets / 1.2 m and 3.0 m pitch unless given); C(1000 m) = 1.0900 (DIN 22101 Table 5); cos δ = 0.99939; LOADED F_H = 0.02 × 1000 × 9.81 × 199.558 = 39153.4 N, F_N = (1.0900 − 1) × 39153.4 = 3523.8 N, F_St = 138.889 × 9.81 × 34.899 = 47550.6 N, T_e = (39153.4 + 3523.8 + 47550.6 + 0) = 90227.7 N (motoring: |P_drum| = 360.911 kW, P_motor = 360.911 × 1.3 / 0.8935 = 525.123 kW); EMPTY T_e = 1.0900 × 0.02 × 1000 × 9.81 × 60.754 + 0 = 12992.7 N (motoring: |P_drum| = 51.971 kW, P_motor = 51.971 × 1.3 / 0.8935 = 75.617 kW); governing loaded → 525.123 kW → 560 kW standard (93.8 %); regenerative power at the motor = 0.000 kW; design |T_e| = 90227.7 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 90227.7/(3.0028 − 1) = 45050.0 N; T1 = 135277.7 N; M_drum = 90227.7 × 1/2 = 45113.9 N·m; n_drum = 60 × 4/(π × 1) = 76.39 rpm; i = 990/76.39 = 12.959; take-up = max(0.15, 0.025 × 1000) = 25.000 m, force 1.5 × 45050.0 = 67574.9 N (validation case c0026-coal-overland-1000m) |
Example 6 — Steep 18° crushed-ore conveyor on 45° idlers
Deep 45° troughing (K = 0.245) at the steepest inclination the engine accepts without a warning.
Given: 800 t/h of crushed ore at 1,800 kg/m³, 150 m incline 18°, belt speed 3 m/s on 45° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 800 / (3.6 × 3 × 1,800) = 0.04115 m² |
|---|---|
| Belt width | K(45°) = 0.245; B = √(Areq / K) = √(0.04115 / 0.245) = 409.8 mm → next standard width 500 mm; A = K · B² = 0.245 × 0.5² = 0.06125 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 3 × 1,800 × 0.06125 = 1,190.7 t/h (margin 48.8 %) → 800.0 vs limit 1,190.7 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 800 / (3.6 × 3) = 74.074 kg/m (design capacity); qB = B × 15 = 0.5 × 15 = 7.50 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 150 × 9.81 × [4.250 + 1.233 + (2 × 7.50 + 74.074) × 0.95106] = 2,654.5 N |
| Secondary resistance | C(150 m) = 1.5800 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.5800 − 1) × 2,654.5 = 1,539.6 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 150 × sin(18°) = 46.353 m: 74.074 × 9.81 × 46.353 = 33,682.9 N (material only — the belt cancels between the strands) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (2,654.5 + 1,539.6 + 33,682.9) = 37,877.0 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.5800 × 0.02 × 150 × 9.81 × 19.749 = 918.3 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 37,877.0 × 3 / 1000 = 113.631 kW; empty 918.3 × 3 / 1000 = 2.755 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 113.631 × 1.3 / 0.8935 = 165.332 kW; empty: motoring 2.755 × 1.3 / 0.8935 = 4.008 kW; the loaded belt governs: Pmotor = 165.332 kW |
| Motor rating | Next standard IEC rating ≥ 165.332 kW → 200 kW (82.7 % loaded) → 165.332 vs limit 200.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 37,877.0 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 37,877.0 / (3.0028 − 1) = 18,911.7 N; T1 = T2 + Te,d = 56,788.7 N (113.6 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 37,877.0 × 0.5/2 = 9,469.2 N·m; ndrum = 60 · v / (π · D) = 60 × 3 / (π × 0.5) = 114.59 rpm; i = nmotor / ndrum = 1,450 / 114.59 = 12.654 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 150) = 3.750 m; Ftake-up = 1.5 × T2 = 1.5 × 18,911.7 = 28,367.5 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 500 mm belt, Te 37,877.0 N loaded, 200 kW motor (loaded belt governs); governing: motor rating |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 800/(3.6 × 3 × 1800) = 0.04115 m²; B = √(0.04115/0.245) = 409.8 mm → 500 mm standard; A = 0.245 × 0.5² = 0.06125 m² → Q_max = 1190.7 t/h; q_G = 800/(3.6 × 3) = 74.074 kg/m; q_B = 7.50 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(150 m) = 1.5800 (DIN 22101 Table 5); cos δ = 0.95106; LOADED F_H = 0.02 × 150 × 9.81 × 90.198 = 2654.5 N, F_N = (1.5800 − 1) × 2654.5 = 1539.6 N, F_St = 74.074 × 9.81 × 46.353 = 33682.9 N, T_e = (2654.5 + 1539.6 + 33682.9 + 0) = 37877.0 N (motoring: |P_drum| = 113.631 kW, P_motor = 113.631 × 1.3 / 0.8935 = 165.332 kW); EMPTY T_e = 1.5800 × 0.02 × 150 × 9.81 × 19.749 + 0 = 918.3 N (motoring: |P_drum| = 2.755 kW, P_motor = 2.755 × 1.3 / 0.8935 = 4.008 kW); governing loaded → 165.332 kW → 200 kW standard (82.7 %); regenerative power at the motor = 0.000 kW; design |T_e| = 37877.0 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 37877.0/(3.0028 − 1) = 18911.7 N; T1 = 56788.7 N; M_drum = 37877.0 × 0.5/2 = 9469.2 N·m; n_drum = 60 × 3/(π × 0.5) = 114.59 rpm; i = 1450/114.59 = 12.654; take-up = max(0.15, 0.025 × 150) = 3.750 m, force 1.5 × 18911.7 = 28367.5 N (validation case c0026-crushed-ore-18deg-45trough) |
Example 7 — Gentle 2° decline with scraper and skirt resistance
A negative inclination gives a negative lift term; with 1 000 N of scraper resistance both cases motor, and the loaded belt (main resistance of the material outweighs its lift) just exceeds the empty belt, so the loaded case sets the 4 kW motor.
Given: 120 t/h of wood chips at 500 kg/m³, 80 m decline 2°, belt speed 1.5 m/s on 35° idlers; belt width to be selected, belt mass 10 kg/m given. Friction factor f = 0.02, special resistances FS 1,000 N. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 120 / (3.6 × 1.5 × 500) = 0.04444 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.04444 / 0.197) = 475.0 mm → next standard width 500 mm; A = K · B² = 0.197 × 0.5² = 0.04925 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 1.5 × 500 × 0.04925 = 133.0 t/h (margin 10.8 %) → 120.0 vs limit 133.0 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 120 / (3.6 × 1.5) = 22.222 kg/m (design capacity); qB = 10.00 kg/m (given); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 80 × 9.81 × [4.250 + 1.233 + (2 × 10.00 + 22.222) × 0.99939] = 748.4 N |
| Secondary resistance | C(80 m) = 1.9200 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.9200 − 1) × 748.4 = 688.5 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 80 × sin(−2°) = −2.792 m: 22.222 × 9.81 × −2.792 = −608.6 N (material only — the belt cancels between the strands); downhill: the material helps drive the belt |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (748.4 + 688.5 − 608.6 + 1,000) = 1,828.2 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.9200 × 0.02 × 80 × 9.81 × 25.471 + 1,000 = 1,767.6 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 1,828.2 × 1.5 / 1000 = 2.742 kW; empty 1,767.6 × 1.5 / 1000 = 2.651 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 2.742 × 1.3 / 0.8935 = 3.990 kW; empty: motoring 2.651 × 1.3 / 0.8935 = 3.858 kW; the loaded belt governs: Pmotor = 3.990 kW |
| Motor rating | Next standard IEC rating ≥ 3.990 kW → 4 kW (99.8 % loaded) → 3.990 vs limit 4.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 1,828.2 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 1,828.2 / (3.0028 − 1) = 912.8 N; T1 = T2 + Te,d = 2,741.1 N (5.5 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 1,828.2 × 0.5/2 = 457.1 N·m; ndrum = 60 · v / (π · D) = 60 × 1.5 / (π × 0.5) = 57.30 rpm; i = nmotor / ndrum = 1,450 / 57.30 = 25.307 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 80) = 2.000 m; Ftake-up = 1.5 × T2 = 1.5 × 912.8 = 1,369.2 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 500 mm belt, Te 1,828.2 N loaded, 4 kW motor (loaded belt governs); governing: motor rating. Motor loading is high (99.8%). Consider next motor size up. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 120/(3.6 × 1.5 × 500) = 0.04444 m²; B = √(0.04444/0.197) = 475.0 mm → 500 mm standard; A = 0.197 × 0.5² = 0.04925 m² → Q_max = 133.0 t/h; q_G = 120/(3.6 × 1.5) = 22.222 kg/m; q_B = 10.00 kg/m (given); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(80 m) = 1.9200 (DIN 22101 Table 5); cos δ = 0.99939; LOADED F_H = 0.02 × 80 × 9.81 × 47.680 = 748.4 N, F_N = (1.9200 − 1) × 748.4 = 688.5 N, F_St = 22.222 × 9.81 × −2.792 = −608.6 N, T_e = (748.4 + 688.5 − 608.6 + 1000) = 1828.2 N (motoring: |P_drum| = 2.742 kW, P_motor = 2.742 × 1.3 / 0.8935 = 3.990 kW); EMPTY T_e = 1.9200 × 0.02 × 80 × 9.81 × 25.471 + 1000 = 1767.6 N (motoring: |P_drum| = 2.651 kW, P_motor = 2.651 × 1.3 / 0.8935 = 3.858 kW); governing loaded → 3.990 kW → 4 kW standard (99.8 %); regenerative power at the motor = 0.000 kW; design |T_e| = 1828.2 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 1828.2/(3.0028 − 1) = 912.8 N; T1 = 2741.1 N; M_drum = 1828.2 × 0.5/2 = 457.1 N·m; n_drum = 60 × 1.5/(π × 0.5) = 57.30 rpm; i = 1450/57.30 = 25.307; take-up = max(0.15, 0.025 × 80) = 2.000 m, force 1.5 × 912.8 = 1369.2 N (validation case c0026-decline-2deg-scrapers) |
Example 8 — Fast 6 m/s belt for wood chips
A high belt speed with a light material: narrow belt, low tensions and a speed warning.
Given: 250 t/h of wood chips at 400 kg/m³, 300 m horizontal, belt speed 6 m/s on 35° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 250 / (3.6 × 6 × 400) = 0.02894 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.02894 / 0.197) = 383.2 mm → next standard width 400 mm; A = K · B² = 0.197 × 0.4² = 0.03152 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 6 × 400 × 0.03152 = 272.3 t/h (margin 8.9 %) → 250.0 vs limit 272.3 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 250 / (3.6 × 6) = 11.574 kg/m (design capacity); qB = B × 15 = 0.4 × 15 = 6.00 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 300 × 9.81 × [4.250 + 1.233 + (2 × 6.00 + 11.574) × 1.00000] = 1,710.3 N |
| Secondary resistance | C(300 m) = 1.3100 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.3100 − 1) × 1,710.3 = 530.2 N |
| Lift resistance | FSt = 0 N (horizontal) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (1,710.3 + 530.2 + 0.0) = 2,240.5 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.3100 × 0.02 × 300 × 9.81 × 17.483 = 1,348.1 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 2,240.5 × 6 / 1000 = 13.443 kW; empty 1,348.1 × 6 / 1000 = 8.088 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 13.443 × 1.3 / 0.8935 = 19.560 kW; empty: motoring 8.088 × 1.3 / 0.8935 = 11.769 kW; the loaded belt governs: Pmotor = 19.560 kW |
| Motor rating | Next standard IEC rating ≥ 19.560 kW → 22 kW (88.9 % loaded) → 19.560 vs limit 22.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 2,240.5 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 2,240.5 / (3.0028 − 1) = 1,118.7 N; T1 = T2 + Te,d = 3,359.2 N (8.4 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 2,240.5 × 0.5/2 = 560.1 N·m; ndrum = 60 · v / (π · D) = 60 × 6 / (π × 0.5) = 229.18 rpm; i = nmotor / ndrum = 1,450 / 229.18 = 6.327 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 300) = 7.500 m; Ftake-up = 1.5 × T2 = 1.5 × 1,118.7 = 1,678.0 N; Constant-tension take-up (L ≥ 200 m) |
| Result | 2/2 checks pass → PASS; 400 mm belt, Te 2,240.5 N loaded, 22 kW motor (loaded belt governs); governing: belt capacity. Belt speed is high (>5 m/s). Ensure proper skirtboards and impact beds. Capacity margin is low (8.9%). Consider wider belt for surge capacity. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 250/(3.6 × 6 × 400) = 0.02894 m²; B = √(0.02894/0.197) = 383.2 mm → 400 mm standard; A = 0.197 × 0.4² = 0.03152 m² → Q_max = 272.3 t/h; q_G = 250/(3.6 × 6) = 11.574 kg/m; q_B = 6.00 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(300 m) = 1.3100 (DIN 22101 Table 5); cos δ = 1.00000; LOADED F_H = 0.02 × 300 × 9.81 × 29.057 = 1710.3 N, F_N = (1.3100 − 1) × 1710.3 = 530.2 N, F_St = 11.574 × 9.81 × 0.000 = 0.0 N, T_e = (1710.3 + 530.2 + 0.0 + 0) = 2240.5 N (motoring: |P_drum| = 13.443 kW, P_motor = 13.443 × 1.3 / 0.8935 = 19.560 kW); EMPTY T_e = 1.3100 × 0.02 × 300 × 9.81 × 17.483 + 0 = 1348.1 N (motoring: |P_drum| = 8.088 kW, P_motor = 8.088 × 1.3 / 0.8935 = 11.769 kW); governing loaded → 19.560 kW → 22 kW standard (88.9 %); regenerative power at the motor = 0.000 kW; design |T_e| = 2240.5 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 2240.5/(3.0028 − 1) = 1118.7 N; T1 = 3359.2 N; M_drum = 2240.5 × 0.5/2 = 560.1 N·m; n_drum = 60 × 6/(π × 0.5) = 229.18 rpm; i = 1450/229.18 = 6.327; take-up = max(0.15, 0.025 × 300) = 7.500 m, force 1.5 × 1118.7 = 1678.0 N (validation case c0026-fast-belt-woodchips) |
Example 9 — Short grain conveyor with 30° idlers
A light-duty 30 m conveyor: the smallest standard belt and a 1.1 kW motor; under 80 m the length coefficient C is large and approximate.
Given: 50 t/h of bulk material at 800 kg/m³, 30 m horizontal, belt speed 2 m/s on 30° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 50 / (3.6 × 2 × 800) = 0.00868 m² |
|---|---|
| Belt width | K(30°) = 0.175; B = √(Areq / K) = √(0.00868 / 0.175) = 222.7 mm → next standard width 300 mm; A = K · B² = 0.175 × 0.3² = 0.01575 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2 × 800 × 0.01575 = 90.7 t/h (margin 81.4 %) → 50.0 vs limit 90.7 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 50 / (3.6 × 2) = 6.944 kg/m (design capacity); qB = B × 15 = 0.3 × 15 = 4.50 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 30 × 9.81 × [4.250 + 1.233 + (2 × 4.50 + 6.944) × 1.00000] = 126.1 N |
| Secondary resistance | C(30 m) = 2.6000 (DIN 22101 Table 5) (under 80 m: approximate, itemise on short conveyors); FN = (C − 1) · FH = (2.6000 − 1) × 126.1 = 201.8 N |
| Lift resistance | FSt = 0 N (horizontal) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (126.1 + 201.8 + 0.0) = 327.9 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 2.6000 × 0.02 × 30 × 9.81 × 14.483 = 221.6 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 327.9 × 2 / 1000 = 0.656 kW; empty 221.6 × 2 / 1000 = 0.443 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 0.656 × 1.3 / 0.8935 = 0.954 kW; empty: motoring 0.443 × 1.3 / 0.8935 = 0.645 kW; the loaded belt governs: Pmotor = 0.954 kW |
| Motor rating | Next standard IEC rating ≥ 0.954 kW → 1.1 kW (86.7 % loaded) → 0.954 vs limit 1.100 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 327.9 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 327.9 / (3.0028 − 1) = 163.7 N; T1 = T2 + Te,d = 491.7 N (1.6 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 327.9 × 0.5/2 = 82.0 N·m; ndrum = 60 · v / (π · D) = 60 × 2 / (π × 0.5) = 76.39 rpm; i = nmotor / ndrum = 1,450 / 76.39 = 18.980 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 30) = 0.750 m; Ftake-up = 1.5 × T2 = 1.5 × 163.7 = 245.6 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 300 mm belt, Te 327.9 N loaded, 1.1 kW motor (loaded belt governs); governing: motor rating. Conveyor shorter than 80 m: secondary resistances (C = 2.60) are approximate here. ISO 5048 / DIN 22101 ask for the feed acceleration, skirt, pulley and belt-bending resistances to be itemised on short conveyors. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 50/(3.6 × 2 × 800) = 0.00868 m²; B = √(0.00868/0.175) = 222.7 mm → 300 mm standard; A = 0.175 × 0.3² = 0.01575 m² → Q_max = 90.7 t/h; q_G = 50/(3.6 × 2) = 6.944 kg/m; q_B = 4.50 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(30 m) = 2.6000 (DIN 22101 Table 5; under 80 m Rulmeca Cq); cos δ = 1.00000; LOADED F_H = 0.02 × 30 × 9.81 × 21.428 = 126.1 N, F_N = (2.6000 − 1) × 126.1 = 201.8 N, F_St = 6.944 × 9.81 × 0.000 = 0.0 N, T_e = (126.1 + 201.8 + 0.0 + 0) = 327.9 N (motoring: |P_drum| = 0.656 kW, P_motor = 0.656 × 1.3 / 0.8935 = 0.954 kW); EMPTY T_e = 2.6000 × 0.02 × 30 × 9.81 × 14.483 + 0 = 221.6 N (motoring: |P_drum| = 0.443 kW, P_motor = 0.443 × 1.3 / 0.8935 = 0.645 kW); governing loaded → 0.954 kW → 1.1 kW standard (86.7 %); regenerative power at the motor = 0.000 kW; design |T_e| = 327.9 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 327.9/(3.0028 − 1) = 163.7 N; T1 = 491.7 N; M_drum = 327.9 × 0.5/2 = 82.0 N·m; n_drum = 60 × 2/(π × 0.5) = 76.39 rpm; i = 1450/76.39 = 18.980; take-up = max(0.15, 0.025 × 30) = 0.750 m, force 1.5 × 163.7 = 245.6 N (validation case c0026-grain-30deg-trough) |
Example 10 — Heavy-duty service factor 1.5 and f = 0.03
A higher friction factor and service factor push the motor up two standard sizes.
Given: 400 t/h of limestone at 1,700 kg/m³, 180 m incline 5°, belt speed 2.5 m/s on 35° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.03. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.5, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 400 / (3.6 × 2.5 × 1,700) = 0.02614 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.02614 / 0.197) = 364.3 mm → next standard width 400 mm; A = K · B² = 0.197 × 0.4² = 0.03152 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2.5 × 1,700 × 0.03152 = 482.3 t/h (margin 20.6 %) → 400.0 vs limit 482.3 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 400 / (3.6 × 2.5) = 44.444 kg/m (design capacity); qB = B × 15 = 0.4 × 15 = 6.00 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.03 × 180 × 9.81 × [4.250 + 1.233 + (2 × 6.00 + 44.444) × 0.99619] = 3,269.2 N |
| Secondary resistance | C(180 m) = 1.5020 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.5020 − 1) × 3,269.2 = 1,641.1 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 180 × sin(5°) = 15.688 m: 44.444 × 9.81 × 15.688 = 6,840.0 N (material only — the belt cancels between the strands) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (3,269.2 + 1,641.1 + 6,840.0) = 11,750.3 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.5020 × 0.03 × 180 × 9.81 × 17.438 = 1,387.5 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 11,750.3 × 2.5 / 1000 = 29.376 kW; empty 1,387.5 × 2.5 / 1000 = 3.469 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 29.376 × 1.5 / 0.8935 = 49.317 kW; empty: motoring 3.469 × 1.5 / 0.8935 = 5.823 kW; the loaded belt governs: Pmotor = 49.317 kW |
| Motor rating | Next standard IEC rating ≥ 49.317 kW → 55 kW (89.7 % loaded) → 49.317 vs limit 55.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 11,750.3 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 11,750.3 / (3.0028 − 1) = 5,866.8 N; T1 = T2 + Te,d = 17,617.1 N (44.0 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 11,750.3 × 0.5/2 = 2,937.6 N·m; ndrum = 60 · v / (π · D) = 60 × 2.5 / (π × 0.5) = 95.49 rpm; i = nmotor / ndrum = 1,450 / 95.49 = 15.184 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 180) = 4.500 m; Ftake-up = 1.5 × T2 = 1.5 × 5,866.8 = 8,800.2 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 400 mm belt, Te 11,750.3 N loaded, 55 kW motor (loaded belt governs); governing: motor rating |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 400/(3.6 × 2.5 × 1700) = 0.02614 m²; B = √(0.02614/0.197) = 364.3 mm → 400 mm standard; A = 0.197 × 0.4² = 0.03152 m² → Q_max = 482.3 t/h; q_G = 400/(3.6 × 2.5) = 44.444 kg/m; q_B = 6.00 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(180 m) = 1.5020 (DIN 22101 Table 5); cos δ = 0.99619; LOADED F_H = 0.03 × 180 × 9.81 × 61.713 = 3269.2 N, F_N = (1.5020 − 1) × 3269.2 = 1641.1 N, F_St = 44.444 × 9.81 × 15.688 = 6840.0 N, T_e = (3269.2 + 1641.1 + 6840.0 + 0) = 11750.3 N (motoring: |P_drum| = 29.376 kW, P_motor = 29.376 × 1.5 / 0.8935 = 49.317 kW); EMPTY T_e = 1.5020 × 0.03 × 180 × 9.81 × 17.438 + 0 = 1387.5 N (motoring: |P_drum| = 3.469 kW, P_motor = 3.469 × 1.5 / 0.8935 = 5.823 kW); governing loaded → 49.317 kW → 55 kW standard (89.7 %); regenerative power at the motor = 0.000 kW; design |T_e| = 11750.3 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 11750.3/(3.0028 − 1) = 5866.8 N; T1 = 17617.1 N; M_drum = 11750.3 × 0.5/2 = 2937.6 N·m; n_drum = 60 × 2.5/(π × 0.5) = 95.49 rpm; i = 1450/95.49 = 15.184; take-up = max(0.15, 0.025 × 180) = 4.500 m, force 1.5 × 5866.8 = 8800.2 N (validation case c0026-heavy-duty-sf-1p5) |
Example 11 — Impact factor 1.3 at a loading point
The impact factor scales the whole traction force, and with it power, tensions and torque.
Given: 600 t/h of blasted rock at 2,000 kg/m³, 110 m incline 8°, belt speed 2 m/s on 35° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02, impact factor 1.3. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 600 / (3.6 × 2 × 2,000) = 0.04167 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.04167 / 0.197) = 459.9 mm → next standard width 500 mm; A = K · B² = 0.197 × 0.5² = 0.04925 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2 × 2,000 × 0.04925 = 709.2 t/h (margin 18.2 %) → 600.0 vs limit 709.2 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 600 / (3.6 × 2) = 83.333 kg/m (design capacity); qB = B × 15 = 0.5 × 15 = 7.50 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 110 × 9.81 × [4.250 + 1.233 + (2 × 7.50 + 83.333) × 0.99027] = 2,219.9 N |
| Secondary resistance | C(110 m) = 1.7400 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.7400 − 1) × 2,219.9 = 1,642.7 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 110 × sin(8°) = 15.309 m: 83.333 × 9.81 × 15.309 = 12,515.1 N (material only — the belt cancels between the strands) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (2,219.9 + 1,642.7 + 12,515.1) × 1.3 = 21,291.1 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.7400 × 0.02 × 110 × 9.81 × 20.337 = 763.7 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 21,291.1 × 2 / 1000 = 42.582 kW; empty 763.7 × 2 / 1000 = 1.527 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 42.582 × 1.3 / 0.8935 = 61.957 kW; empty: motoring 1.527 × 1.3 / 0.8935 = 2.222 kW; the loaded belt governs: Pmotor = 61.957 kW |
| Motor rating | Next standard IEC rating ≥ 61.957 kW → 75 kW (82.6 % loaded) → 61.957 vs limit 75.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 21,291.1 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 21,291.1 / (3.0028 − 1) = 10,630.5 N; T1 = T2 + Te,d = 31,921.6 N (63.8 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 21,291.1 × 0.5/2 = 5,322.8 N·m; ndrum = 60 · v / (π · D) = 60 × 2 / (π × 0.5) = 76.39 rpm; i = nmotor / ndrum = 1,450 / 76.39 = 18.980 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 110) = 2.750 m; Ftake-up = 1.5 × T2 = 1.5 × 10,630.5 = 15,945.7 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 500 mm belt, Te 21,291.1 N loaded, 75 kW motor (loaded belt governs); governing: belt capacity |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 600/(3.6 × 2 × 2000) = 0.04167 m²; B = √(0.04167/0.197) = 459.9 mm → 500 mm standard; A = 0.197 × 0.5² = 0.04925 m² → Q_max = 709.2 t/h; q_G = 600/(3.6 × 2) = 83.333 kg/m; q_B = 7.50 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(110 m) = 1.7400 (DIN 22101 Table 5); cos δ = 0.99027; LOADED F_H = 0.02 × 110 × 9.81 × 102.860 = 2219.9 N, F_N = (1.7400 − 1) × 2219.9 = 1642.7 N, F_St = 83.333 × 9.81 × 15.309 = 12515.1 N, T_e = (2219.9 + 1642.7 + 12515.1 + 0) × 1.3 = 21291.1 N (motoring: |P_drum| = 42.582 kW, P_motor = 42.582 × 1.3 / 0.8935 = 61.957 kW); EMPTY T_e = 1.7400 × 0.02 × 110 × 9.81 × 20.337 + 0 = 763.7 N (motoring: |P_drum| = 1.527 kW, P_motor = 1.527 × 1.3 / 0.8935 = 2.222 kW); governing loaded → 61.957 kW → 75 kW standard (82.6 %); regenerative power at the motor = 0.000 kW; design |T_e| = 21291.1 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 21291.1/(3.0028 − 1) = 10630.5 N; T1 = 31921.6 N; M_drum = 21291.1 × 0.5/2 = 5322.8 N·m; n_drum = 60 × 2/(π × 0.5) = 76.39 rpm; i = 1450/76.39 = 18.980; take-up = max(0.15, 0.025 × 110) = 2.750 m, force 1.5 × 10630.5 = 15945.7 N (validation case c0026-impact-factor-1p3) |
Example 12 — Inclined iron ore conveyor at 15°
Lift resistance on a 15° incline is several times the main and secondary resistances combined and sets a 132 kW motor.
Given: 500 t/h of bulk material at 1,400 kg/m³, 200 m incline 15°, belt speed 2.5 m/s on 35° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 500 / (3.6 × 2.5 × 1,400) = 0.03968 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.03968 / 0.197) = 448.8 mm → next standard width 500 mm; A = K · B² = 0.197 × 0.5² = 0.04925 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2.5 × 1,400 × 0.04925 = 620.5 t/h (margin 24.1 %) → 500.0 vs limit 620.5 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 500 / (3.6 × 2.5) = 55.556 kg/m (design capacity); qB = B × 15 = 0.5 × 15 = 7.50 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 200 × 9.81 × [4.250 + 1.233 + (2 × 7.50 + 55.556) × 0.96593] = 2,889.4 N |
| Secondary resistance | C(200 m) = 1.4500 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.4500 − 1) × 2,889.4 = 1,300.2 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 200 × sin(15°) = 51.764 m: 55.556 × 9.81 × 51.764 = 28,211.3 N (material only — the belt cancels between the strands) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (2,889.4 + 1,300.2 + 28,211.3) = 32,400.9 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.4500 × 0.02 × 200 × 9.81 × 19.972 = 1,136.4 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 32,400.9 × 2.5 / 1000 = 81.002 kW; empty 1,136.4 × 2.5 / 1000 = 2.841 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 81.002 × 1.3 / 0.8935 = 117.858 kW; empty: motoring 2.841 × 1.3 / 0.8935 = 4.134 kW; the loaded belt governs: Pmotor = 117.858 kW |
| Motor rating | Next standard IEC rating ≥ 117.858 kW → 132 kW (89.3 % loaded) → 117.858 vs limit 132.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 32,400.9 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 32,400.9 / (3.0028 − 1) = 16,177.5 N; T1 = T2 + Te,d = 48,578.5 N (97.2 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 32,400.9 × 0.5/2 = 8,100.2 N·m; ndrum = 60 · v / (π · D) = 60 × 2.5 / (π × 0.5) = 95.49 rpm; i = nmotor / ndrum = 1,450 / 95.49 = 15.184 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 200) = 5.000 m; Ftake-up = 1.5 × T2 = 1.5 × 16,177.5 = 24,266.3 N; Constant-tension take-up (L ≥ 200 m) |
| Result | 2/2 checks pass → PASS; 500 mm belt, Te 32,400.9 N loaded, 132 kW motor (loaded belt governs); governing: motor rating |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 500/(3.6 × 2.5 × 1400) = 0.03968 m²; B = √(0.03968/0.197) = 448.8 mm → 500 mm standard; A = 0.197 × 0.5² = 0.04925 m² → Q_max = 620.6 t/h; q_G = 500/(3.6 × 2.5) = 55.556 kg/m; q_B = 7.50 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(200 m) = 1.4500 (DIN 22101 Table 5); cos δ = 0.96593; LOADED F_H = 0.02 × 200 × 9.81 × 73.635 = 2889.4 N, F_N = (1.4500 − 1) × 2889.4 = 1300.2 N, F_St = 55.556 × 9.81 × 51.764 = 28211.3 N, T_e = (2889.4 + 1300.2 + 28211.3 + 0) = 32400.9 N (motoring: |P_drum| = 81.002 kW, P_motor = 81.002 × 1.3 / 0.8935 = 117.858 kW); EMPTY T_e = 1.4500 × 0.02 × 200 × 9.81 × 19.972 + 0 = 1136.4 N (motoring: |P_drum| = 2.841 kW, P_motor = 2.841 × 1.3 / 0.8935 = 4.134 kW); governing loaded → 117.858 kW → 132 kW standard (89.3 %); regenerative power at the motor = 0.000 kW; design |T_e| = 32400.9 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 32400.9/(3.0028 − 1) = 16177.5 N; T1 = 48578.5 N; M_drum = 32400.9 × 0.5/2 = 8100.2 N·m; n_drum = 60 × 2.5/(π × 0.5) = 95.49 rpm; i = 1450/95.49 = 15.184; take-up = max(0.15, 0.025 × 200) = 5.000 m, force 1.5 × 16177.5 = 24266.3 N (validation case c0026-iron-ore-15deg) |
Example 13 — Lagged pulley with snub, 240° wrap
A high Euler factor (μ = 0.4, θ = 240°) lowers the slack-side tension for the same traction.
Given: 350 t/h of bulk material at 1,600 kg/m³, 140 m incline 6°, belt speed 2.5 m/s on 35° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 240°, μ = 0.4, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 350 / (3.6 × 2.5 × 1,600) = 0.02431 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.02431 / 0.197) = 351.3 mm → next standard width 400 mm; A = K · B² = 0.197 × 0.4² = 0.03152 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2.5 × 1,600 × 0.03152 = 453.9 t/h (margin 29.7 %) → 350.0 vs limit 453.9 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 350 / (3.6 × 2.5) = 38.889 kg/m (design capacity); qB = B × 15 = 0.4 × 15 = 6.00 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 140 × 9.81 × [4.250 + 1.233 + (2 × 6.00 + 38.889) × 0.99452] = 1,540.8 N |
| Secondary resistance | C(140 m) = 1.6200 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.6200 − 1) × 1,540.8 = 955.3 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 140 × sin(6°) = 14.634 m: 38.889 × 9.81 × 14.634 = 5,582.9 N (material only — the belt cancels between the strands) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (1,540.8 + 955.3 + 5,582.9) = 8,078.9 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.6200 × 0.02 × 140 × 9.81 × 17.418 = 775.1 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 8,078.9 × 2.5 / 1000 = 20.197 kW; empty 775.1 × 2.5 / 1000 = 1.938 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 20.197 × 1.3 / 0.8935 = 29.387 kW; empty: motoring 1.938 × 1.3 / 0.8935 = 2.819 kW; the loaded belt governs: Pmotor = 29.387 kW |
| Motor rating | Next standard IEC rating ≥ 29.387 kW → 30 kW (98.0 % loaded) → 29.387 vs limit 30.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 8,078.9 N (loaded); eμθ = e0.4 × 240π/180 = 5.3416; T2 = Te,d / (eμθ − 1) = 8,078.9 / (5.3416 − 1) = 1,860.8 N; T1 = T2 + Te,d = 9,939.8 N (24.8 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 8,078.9 × 0.5/2 = 2,019.7 N·m; ndrum = 60 · v / (π · D) = 60 × 2.5 / (π × 0.5) = 95.49 rpm; i = nmotor / ndrum = 1,450 / 95.49 = 15.184 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 140) = 3.500 m; Ftake-up = 1.5 × T2 = 1.5 × 1,860.8 = 2,791.3 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 400 mm belt, Te 8,078.9 N loaded, 30 kW motor (loaded belt governs); governing: motor rating. Motor loading is high (98.0%). Consider next motor size up. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 350/(3.6 × 2.5 × 1600) = 0.02431 m²; B = √(0.02431/0.197) = 351.3 mm → 400 mm standard; A = 0.197 × 0.4² = 0.03152 m² → Q_max = 453.9 t/h; q_G = 350/(3.6 × 2.5) = 38.889 kg/m; q_B = 6.00 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(140 m) = 1.6200 (DIN 22101 Table 5); cos δ = 0.99452; LOADED F_H = 0.02 × 140 × 9.81 × 56.093 = 1540.8 N, F_N = (1.6200 − 1) × 1540.8 = 955.3 N, F_St = 38.889 × 9.81 × 14.634 = 5582.9 N, T_e = (1540.8 + 955.3 + 5582.9 + 0) = 8078.9 N (motoring: |P_drum| = 20.197 kW, P_motor = 20.197 × 1.3 / 0.8935 = 29.387 kW); EMPTY T_e = 1.6200 × 0.02 × 140 × 9.81 × 17.418 + 0 = 775.1 N (motoring: |P_drum| = 1.938 kW, P_motor = 1.938 × 1.3 / 0.8935 = 2.819 kW); governing loaded → 29.387 kW → 30 kW standard (98.0 %); regenerative power at the motor = 0.000 kW; design |T_e| = 8078.9 N (loaded); e^(μθ) = e^(0.4 × 240π/180) = 5.3416; T2 = 8078.9/(5.3416 − 1) = 1860.8 N; T1 = 9939.8 N; M_drum = 8078.9 × 0.5/2 = 2019.7 N·m; n_drum = 60 × 2.5/(π × 0.5) = 95.49 rpm; i = 1450/95.49 = 15.184; take-up = max(0.15, 0.025 × 140) = 3.500 m, force 1.5 × 1860.8 = 2791.3 N (validation case c0026-lagged-snub-wrap-240) |
Example 14 — Mild 3.5° decline: regenerative loaded, motoring empty
Loaded, the material just overcomes the running resistance (regenerative); empty, the belt must be driven. The empty-belt motoring case sets the motor and the tensions.
Given: 400 t/h of coal at 850 kg/m³, 800 m decline 3.5°, belt speed 2.5 m/s on 35° idlers; belt width to be selected, belt mass 20 kg/m given. Friction factor f = 0.02, special resistances FS 2,000 N. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 400 / (3.6 × 2.5 × 850) = 0.05229 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.05229 / 0.197) = 515.2 mm → next standard width 650 mm; A = K · B² = 0.197 × 0.65² = 0.08323 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2.5 × 850 × 0.08323 = 636.7 t/h (margin 59.2 %) → 400.0 vs limit 636.7 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 400 / (3.6 × 2.5) = 44.444 kg/m (design capacity); qB = 20.00 kg/m (given); qRO = 7.583, qRU = 2.167 kg/m (typical 650 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 800 × 9.81 × [7.583 + 2.167 + (2 × 20.00 + 44.444) × 0.99813] = 14,760.0 N |
| Secondary resistance | C(800 m) = 1.1200 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.1200 − 1) × 14,760.0 = 1,771.2 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 800 × sin(−3.5°) = −48.839 m: 44.444 × 9.81 × −48.839 = −21,293.7 N (material only — the belt cancels between the strands); downhill: the material helps drive the belt |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (14,760.0 + 1,771.2 − 21,293.7 + 2,000) = −2,762.5 N (regenerative) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.1200 × 0.02 × 800 × 9.81 × 49.675 + 2,000 = 10,732.7 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded −2,762.5 × 2.5 / 1000 = −6.906 kW; empty 10,732.7 × 2.5 / 1000 = 26.832 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: regenerative 6.906 × 1.3 × 0.8935 = 8.022 kW; empty: motoring 26.832 × 1.3 / 0.8935 = 39.040 kW; the empty belt governs: Pmotor = 39.040 kW |
| Regenerative braking | Power fed back through the motor Pregen = |Pdrum| × η = 6.171 kW: Absorb 6.2 kW: regenerative (active front end) VFD or braking resistor, plus a fail-safe mechanical brake sized for the loaded decline |
| Motor rating | Next standard IEC rating ≥ 39.040 kW → 45 kW (86.8 % loaded) → 39.040 vs limit 45.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 10,732.7 N (empty); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 10,732.7 / (3.0028 − 1) = 5,358.7 N; T1 = T2 + Te,d = 16,091.4 N (24.8 N/mm of width); regenerative: the tight strand is the one leaving the drive pulley |
| Drum and gearbox | Mdrum = Te,d × D/2 = 10,732.7 × 0.5/2 = 2,683.2 N·m; ndrum = 60 · v / (π · D) = 60 × 2.5 / (π × 0.5) = 95.49 rpm; i = nmotor / ndrum = 1,450 / 95.49 = 15.184 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 800) = 20.000 m; Ftake-up = 1.5 × T2 = 1.5 × 5,358.7 = 8,038.1 N; Constant-tension take-up (L ≥ 200 m) |
| Result | 2/2 checks pass → PASS; 650 mm belt, Te −2,762.5 N loaded, 45 kW motor (empty belt governs, regenerative — braking required); governing: motor rating. Regenerative conveyor: the loaded belt overhauls the drive (T_e loaded -2762 N, empty 10733 N). The drive must absorb about 6.2 kW at the motor terminals: use a regenerative (active front end) VFD or a braking resistor, plus a fail-safe mechanical brake sized for the loaded decline (the belt runs away on loss of power). Regenerative power is maximised by LOW running resistance: re-check with the lower-bound friction factor (DIN 22101 suggests f ≈ 0.012–0.016 for braked downhill conveyors; f = 0.02 used here). Drive changes mode with load: regenerative loaded (-6.91 kW at the drum), motoring empty (26.83 kW). The drive must control torque in both directions. The empty belt governs the drive (39.04 kW required vs 8.02 kW loaded): on this decline the material helps drive the belt. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 400/(3.6 × 2.5 × 850) = 0.05229 m²; B = √(0.05229/0.197) = 515.2 mm → 650 mm standard; A = 0.197 × 0.65² = 0.08323 m² → Q_max = 636.7 t/h; q_G = 400/(3.6 × 2.5) = 44.444 kg/m; q_B = 20.00 kg/m (given); q_RO = 7.583, q_RU = 2.167 kg/m (Rulmeca Tab. 11 650 mm sets / 1.2 m and 3.0 m pitch unless given); C(800 m) = 1.1200 (DIN 22101 Table 5); cos δ = 0.99813; LOADED F_H = 0.02 × 800 × 9.81 × 94.037 = 14760.0 N, F_N = (1.1200 − 1) × 14760.0 = 1771.2 N, F_St = 44.444 × 9.81 × −48.839 = −21293.7 N, T_e = (14760.0 + 1771.2 − 21293.7 + 2000) = −2762.5 N (regenerative: |P_drum| = 6.906 kW, P_motor = 6.906 × 1.3 × 0.8935 = 8.022 kW); EMPTY T_e = 1.1200 × 0.02 × 800 × 9.81 × 49.675 + 2000 = 10732.7 N (motoring: |P_drum| = 26.832 kW, P_motor = 26.832 × 1.3 / 0.8935 = 39.040 kW); governing empty → 39.040 kW → 45 kW standard (86.8 %); regenerative power at the motor = 6.171 kW; design |T_e| = 10732.7 N (empty); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 10732.7/(3.0028 − 1) = 5358.7 N; T1 = 16091.4 N; M_drum = 10732.7 × 0.5/2 = 2683.2 N·m; n_drum = 60 × 2.5/(π × 0.5) = 95.49 rpm; i = 1450/95.49 = 15.184; take-up = max(0.15, 0.025 × 800) = 20.000 m, force 1.5 × 5358.7 = 8038.1 N (validation case c0026-mild-decline-empty-governs) |
Example 15 — 2-pole motor on a 315 mm drive pulley
A 2900 rpm motor and small pulley give a high gearbox ratio; efficiencies are overridden.
Given: 100 t/h of bulk material at 1,200 kg/m³, 45 m horizontal, belt speed 1.2 m/s on 35° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 0.315 m pulley, wrap 210°, μ = 0.3, motor 2,900 rpm, service factor 1.3, efficiencies gearbox 0.92 / coupling 0.98 / motor 0.9.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 100 / (3.6 × 1.2 × 1,200) = 0.01929 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.01929 / 0.197) = 312.9 mm → next standard width 400 mm; A = K · B² = 0.197 × 0.4² = 0.03152 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 1.2 × 1,200 × 0.03152 = 163.4 t/h (margin 63.4 %) → 100.0 vs limit 163.4 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 100 / (3.6 × 1.2) = 23.148 kg/m (design capacity); qB = B × 15 = 0.4 × 15 = 6.00 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 45 × 9.81 × [4.250 + 1.233 + (2 × 6.00 + 23.148) × 1.00000] = 358.7 N |
| Secondary resistance | C(45 m) = 2.1500 (DIN 22101 Table 5) (under 80 m: approximate, itemise on short conveyors); FN = (C − 1) · FH = (2.1500 − 1) × 358.7 = 412.5 N |
| Lift resistance | FSt = 0 N (horizontal) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (358.7 + 412.5 + 0.0) = 771.3 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 2.1500 × 0.02 × 45 × 9.81 × 17.483 = 331.9 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 771.3 × 1.2 / 1000 = 0.926 kW; empty 331.9 × 1.2 / 1000 = 0.398 kW |
| Motor power | η = 0.92 × 0.98 × 0.9 = 0.8114; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 0.926 × 1.3 / 0.8114 = 1.483 kW; empty: motoring 0.398 × 1.3 / 0.8114 = 0.638 kW; the loaded belt governs: Pmotor = 1.483 kW |
| Motor rating | Next standard IEC rating ≥ 1.483 kW → 1.5 kW (98.9 % loaded) → 1.483 vs limit 1.500 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 771.3 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 771.3 / (3.0028 − 1) = 385.1 N; T1 = T2 + Te,d = 1,156.4 N (2.9 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 771.3 × 0.315/2 = 121.5 N·m; ndrum = 60 · v / (π · D) = 60 × 1.2 / (π × 0.315) = 72.76 rpm; i = nmotor / ndrum = 2,900 / 72.76 = 39.859 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 45) = 1.125 m; Ftake-up = 1.5 × T2 = 1.5 × 385.1 = 577.6 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 400 mm belt, Te 771.3 N loaded, 1.5 kW motor (loaded belt governs); governing: motor rating. Conveyor shorter than 80 m: secondary resistances (C = 2.15) are approximate here. ISO 5048 / DIN 22101 ask for the feed acceleration, skirt, pulley and belt-bending resistances to be itemised on short conveyors. Motor loading is high (98.9%). Consider next motor size up. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 100/(3.6 × 1.2 × 1200) = 0.01929 m²; B = √(0.01929/0.197) = 312.9 mm → 400 mm standard; A = 0.197 × 0.4² = 0.03152 m² → Q_max = 163.4 t/h; q_G = 100/(3.6 × 1.2) = 23.148 kg/m; q_B = 6.00 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(45 m) = 2.1500 (DIN 22101 Table 5; under 80 m Rulmeca Cq); cos δ = 1.00000; LOADED F_H = 0.02 × 45 × 9.81 × 40.631 = 358.7 N, F_N = (2.1500 − 1) × 358.7 = 412.5 N, F_St = 23.148 × 9.81 × 0.000 = 0.0 N, T_e = (358.7 + 412.5 + 0.0 + 0) = 771.3 N (motoring: |P_drum| = 0.926 kW, P_motor = 0.926 × 1.3 / 0.8114 = 1.483 kW); EMPTY T_e = 2.1500 × 0.02 × 45 × 9.81 × 17.483 + 0 = 331.9 N (motoring: |P_drum| = 0.398 kW, P_motor = 0.398 × 1.3 / 0.8114 = 0.638 kW); governing loaded → 1.483 kW → 1.5 kW standard (98.9 %); regenerative power at the motor = 0.000 kW; design |T_e| = 771.3 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 771.3/(3.0028 − 1) = 385.1 N; T1 = 1156.4 N; M_drum = 771.3 × 0.315/2 = 121.5 N·m; n_drum = 60 × 1.2/(π × 0.315) = 72.76 rpm; i = 2900/72.76 = 39.859; take-up = max(0.15, 0.025 × 45) = 1.125 m, force 1.5 × 385.1 = 577.6 N (validation case c0026-motor-2900rpm-small-pulley) |
Example 16 — 6-pole motor on a 1.25 m drive pulley
A slow motor and large pulley: low gearbox ratio and high drum torque.
Given: 1,200 t/h of bulk material at 1,600 kg/m³, 250 m incline 4°, belt speed 3.5 m/s on 35° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 1.25 m pulley, wrap 210°, μ = 0.3, motor 960 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 1,200 / (3.6 × 3.5 × 1,600) = 0.05952 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.05952 / 0.197) = 549.7 mm → next standard width 650 mm; A = K · B² = 0.197 × 0.65² = 0.08323 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 3.5 × 1,600 × 0.08323 = 1,678.0 t/h (margin 39.8 %) → 1,200.0 vs limit 1,678.0 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 1,200 / (3.6 × 3.5) = 95.238 kg/m (design capacity); qB = B × 15 = 0.65 × 15 = 9.75 kg/m (estimated); qRO = 7.583, qRU = 2.167 kg/m (typical 650 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 250 × 9.81 × [7.583 + 2.167 + (2 × 9.75 + 95.238) × 0.99756] = 6,092.4 N |
| Secondary resistance | C(250 m) = 1.3800 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.3800 − 1) × 6,092.4 = 2,315.1 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 250 × sin(4°) = 17.439 m: 95.238 × 9.81 × 17.439 = 16,293.1 N (material only — the belt cancels between the strands) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (6,092.4 + 2,315.1 + 16,293.1) = 24,700.7 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.3800 × 0.02 × 250 × 9.81 × 29.202 = 1,976.7 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 24,700.7 × 3.5 / 1000 = 86.452 kW; empty 1,976.7 × 3.5 / 1000 = 6.918 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 86.452 × 1.3 / 0.8935 = 125.788 kW; empty: motoring 6.918 × 1.3 / 0.8935 = 10.066 kW; the loaded belt governs: Pmotor = 125.788 kW |
| Motor rating | Next standard IEC rating ≥ 125.788 kW → 132 kW (95.3 % loaded) → 125.788 vs limit 132.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 24,700.7 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 24,700.7 / (3.0028 − 1) = 12,332.8 N; T1 = T2 + Te,d = 37,033.5 N (57.0 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 24,700.7 × 1.25/2 = 15,437.9 N·m; ndrum = 60 · v / (π · D) = 60 × 3.5 / (π × 1.25) = 53.48 rpm; i = nmotor / ndrum = 960 / 53.48 = 17.952 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 250) = 6.250 m; Ftake-up = 1.5 × T2 = 1.5 × 12,332.8 = 18,499.3 N; Constant-tension take-up (L ≥ 200 m) |
| Result | 2/2 checks pass → PASS; 650 mm belt, Te 24,700.7 N loaded, 132 kW motor (loaded belt governs); governing: motor rating. Motor loading is high (95.3%). Consider next motor size up. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 1200/(3.6 × 3.5 × 1600) = 0.05952 m²; B = √(0.05952/0.197) = 549.7 mm → 650 mm standard; A = 0.197 × 0.65² = 0.08323 m² → Q_max = 1678.0 t/h; q_G = 1200/(3.6 × 3.5) = 95.238 kg/m; q_B = 9.75 kg/m (15 × B); q_RO = 7.583, q_RU = 2.167 kg/m (Rulmeca Tab. 11 650 mm sets / 1.2 m and 3.0 m pitch unless given); C(250 m) = 1.3800 (DIN 22101 Table 5); cos δ = 0.99756; LOADED F_H = 0.02 × 250 × 9.81 × 124.209 = 6092.4 N, F_N = (1.3800 − 1) × 6092.4 = 2315.1 N, F_St = 95.238 × 9.81 × 17.439 = 16293.1 N, T_e = (6092.4 + 2315.1 + 16293.1 + 0) = 24700.7 N (motoring: |P_drum| = 86.452 kW, P_motor = 86.452 × 1.3 / 0.8935 = 125.788 kW); EMPTY T_e = 1.3800 × 0.02 × 250 × 9.81 × 29.202 + 0 = 1976.7 N (motoring: |P_drum| = 6.918 kW, P_motor = 6.918 × 1.3 / 0.8935 = 10.066 kW); governing loaded → 125.788 kW → 132 kW standard (95.3 %); regenerative power at the motor = 0.000 kW; design |T_e| = 24700.7 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 24700.7/(3.0028 − 1) = 12332.8 N; T1 = 37033.5 N; M_drum = 24700.7 × 1.25/2 = 15437.9 N·m; n_drum = 60 × 3.5/(π × 1.25) = 53.48 rpm; i = 960/53.48 = 17.952; take-up = max(0.15, 0.025 × 250) = 6.250 m, force 1.5 × 12332.8 = 18499.3 N (validation case c0026-motor-960rpm-large-pulley) |
Example 17 — Published worked example: 1000 t/h, 150 m, 15 m lift
The Rulmeca design-guide example (1000 mm belt, q_B 9.9, q_RO 14.8, q_RU 4.4 kg/m, f 0.017): material load at the design capacity q_G = Q/(3.6·v) = 120.8 kg/m, lift on the material only. Before the 2026-10-23 fix the tool used the full-trough 236.4 kg/m and doubled the lift.
Given: 1,000 t/h of crushed material at 1,200 kg/m³, 150 m incline 5.7392°, belt speed 2.3 m/s on 30° idlers; belt width 1,000 mm given, belt mass 9.9 kg/m given, idler rotating mass qRO 14.8 / qRU 4.4 kg/m. Friction factor f = 0.017. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1, efficiencies gearbox 0.9 / coupling 0.98 / motor 0.975.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 1,000 / (3.6 × 2.3 × 1,200) = 0.10064 m² |
|---|---|
| Belt width | K(30°) = 0.175; B = 1,000 mm (given); A = K · B² = 0.175 × 1² = 0.17500 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2.3 × 1,200 × 0.17500 = 1,738.8 t/h (margin 73.9 %) → 1,000.0 vs limit 1,738.8 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 1,000 / (3.6 × 2.3) = 120.773 kg/m (design capacity); qB = 9.90 kg/m (given); qRO = 14.800, qRU = 4.400 kg/m (given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.017 × 150 × 9.81 × [14.800 + 4.400 + (2 × 9.90 + 120.773) × 0.99499] = 3,979.2 N |
| Secondary resistance | C(150 m) = 1.5800 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.5800 − 1) × 3,979.2 = 2,307.9 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 150 × sin(5.7392°) = 15.000 m: 120.773 × 9.81 × 15.000 = 17,771.8 N (material only — the belt cancels between the strands) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (3,979.2 + 2,307.9 + 17,771.8) = 24,058.9 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.5800 × 0.017 × 150 × 9.81 × 38.901 = 1,537.5 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 24,058.9 × 2.3 / 1000 = 55.336 kW; empty 1,537.5 × 2.3 / 1000 = 3.536 kW |
| Motor power | η = 0.9 × 0.98 × 0.975 = 0.8599; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 55.336 × 1 / 0.8599 = 64.347 kW; empty: motoring 3.536 × 1 / 0.8599 = 4.112 kW; the loaded belt governs: Pmotor = 64.347 kW |
| Motor rating | Next standard IEC rating ≥ 64.347 kW → 75 kW (85.8 % loaded) → 64.347 vs limit 75.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 24,058.9 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 24,058.9 / (3.0028 − 1) = 12,012.4 N; T1 = T2 + Te,d = 36,071.3 N (36.1 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 24,058.9 × 0.5/2 = 6,014.7 N·m; ndrum = 60 · v / (π · D) = 60 × 2.3 / (π × 0.5) = 87.85 rpm; i = nmotor / ndrum = 1,450 / 87.85 = 16.505 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 150) = 3.750 m; Ftake-up = 1.5 × T2 = 1.5 × 12,012.4 = 18,018.6 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 1,000 mm belt, Te 24,058.9 N loaded, 75 kW motor (loaded belt governs); governing: motor rating |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 1000/(3.6 × 2.3 × 1200) = 0.10064 m²; B = 1000 mm given; A = 0.175 × 1² = 0.17500 m² → Q_max = 1738.8 t/h; q_G = 1000/(3.6 × 2.3) = 120.773 kg/m; q_B = 9.90 kg/m (given); q_RO = 14.8, q_RU = 4.4 kg/m (given); C(150 m) = 1.5800 (DIN 22101 Table 5); cos δ = 0.99499; LOADED F_H = 0.017 × 150 × 9.81 × 159.068 = 3979.2 N, F_N = (1.5800 − 1) × 3979.2 = 2307.9 N, F_St = 120.773 × 9.81 × 15.000 = 17771.8 N, T_e = (3979.2 + 2307.9 + 17771.8 + 0) = 24058.9 N (motoring: |P_drum| = 55.336 kW, P_motor = 55.336 × 1 / 0.8599 = 64.347 kW); EMPTY T_e = 1.5800 × 0.017 × 150 × 9.81 × 38.901 + 0 = 1537.5 N (motoring: |P_drum| = 3.536 kW, P_motor = 3.536 × 1 / 0.8599 = 4.112 kW); governing loaded → 64.347 kW → 75 kW standard (85.8 %); regenerative power at the motor = 0.000 kW; design |T_e| = 24058.9 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 24058.9/(3.0028 − 1) = 12012.4 N; T1 = 36071.3 N; M_drum = 24058.9 × 0.5/2 = 6014.7 N·m; n_drum = 60 × 2.3/(π × 0.5) = 87.85 rpm; i = 1450/87.85 = 16.505; take-up = max(0.15, 0.025 × 150) = 3.750 m, force 1.5 × 12012.4 = 18018.6 N (validation case c0026-rulmeca-worked-example) |
Example 18 — Flat 20° troughing for dry sand
Shallow 20° idlers (K = 0.143) need a wider belt for the same capacity.
Given: 150 t/h of dry sand at 1,500 kg/m³, 60 m horizontal, belt speed 1.5 m/s on 20° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 150 / (3.6 × 1.5 × 1,500) = 0.01852 m² |
|---|---|
| Belt width | K(20°) = 0.143; B = √(Areq / K) = √(0.01852 / 0.143) = 359.9 mm → next standard width 400 mm; A = K · B² = 0.143 × 0.4² = 0.02288 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 1.5 × 1,500 × 0.02288 = 185.3 t/h (margin 23.6 %) → 150.0 vs limit 185.3 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 150 / (3.6 × 1.5) = 27.778 kg/m (design capacity); qB = B × 15 = 0.4 × 15 = 6.00 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 60 × 9.81 × [4.250 + 1.233 + (2 × 6.00 + 27.778) × 1.00000] = 532.8 N |
| Secondary resistance | C(60 m) = 2.0000 (DIN 22101 Table 5) (under 80 m: approximate, itemise on short conveyors); FN = (C − 1) · FH = (2.0000 − 1) × 532.8 = 532.8 N |
| Lift resistance | FSt = 0 N (horizontal) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (532.8 + 532.8 + 0.0) = 1,065.6 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 2.0000 × 0.02 × 60 × 9.81 × 17.483 = 411.6 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 1,065.6 × 1.5 / 1000 = 1.598 kW; empty 411.6 × 1.5 / 1000 = 0.617 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 1.598 × 1.3 / 0.8935 = 2.326 kW; empty: motoring 0.617 × 1.3 / 0.8935 = 0.898 kW; the loaded belt governs: Pmotor = 2.326 kW |
| Motor rating | Next standard IEC rating ≥ 2.326 kW → 3 kW (77.5 % loaded) → 2.326 vs limit 3.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 1,065.6 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 1,065.6 / (3.0028 − 1) = 532.1 N; T1 = T2 + Te,d = 1,597.7 N (4.0 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 1,065.6 × 0.5/2 = 266.4 N·m; ndrum = 60 · v / (π · D) = 60 × 1.5 / (π × 0.5) = 57.30 rpm; i = nmotor / ndrum = 1,450 / 57.30 = 25.307 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 60) = 1.500 m; Ftake-up = 1.5 × T2 = 1.5 × 532.1 = 798.1 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 400 mm belt, Te 1,065.6 N loaded, 3 kW motor (loaded belt governs); governing: belt capacity. Conveyor shorter than 80 m: secondary resistances (C = 2.00) are approximate here. ISO 5048 / DIN 22101 ask for the feed acceleration, skirt, pulley and belt-bending resistances to be itemised on short conveyors. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 150/(3.6 × 1.5 × 1500) = 0.01852 m²; B = √(0.01852/0.143) = 359.9 mm → 400 mm standard; A = 0.143 × 0.4² = 0.02288 m² → Q_max = 185.3 t/h; q_G = 150/(3.6 × 1.5) = 27.778 kg/m; q_B = 6.00 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(60 m) = 2.0000 (DIN 22101 Table 5; under 80 m Rulmeca Cq); cos δ = 1.00000; LOADED F_H = 0.02 × 60 × 9.81 × 45.261 = 532.8 N, F_N = (2.0000 − 1) × 532.8 = 532.8 N, F_St = 27.778 × 9.81 × 0.000 = 0.0 N, T_e = (532.8 + 532.8 + 0.0 + 0) = 1065.6 N (motoring: |P_drum| = 1.598 kW, P_motor = 1.598 × 1.3 / 0.8935 = 2.326 kW); EMPTY T_e = 2.0000 × 0.02 × 60 × 9.81 × 17.483 + 0 = 411.6 N (motoring: |P_drum| = 0.617 kW, P_motor = 0.617 × 1.3 / 0.8935 = 0.898 kW); governing loaded → 2.326 kW → 3 kW standard (77.5 %); regenerative power at the motor = 0.000 kW; design |T_e| = 1065.6 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 1065.6/(3.0028 − 1) = 532.1 N; T1 = 1597.7 N; M_drum = 1065.6 × 0.5/2 = 266.4 N·m; n_drum = 60 × 1.5/(π × 0.5) = 57.30 rpm; i = 1450/57.30 = 25.307; take-up = max(0.15, 0.025 × 60) = 1.500 m, force 1.5 × 532.1 = 798.1 N (validation case c0026-sand-20deg-trough) |
Example 19 — 5 m feeder conveyor at the take-up floor
The shortest conveyor the engine accepts: take-up travel is held at the 0.15 m minimum.
Given: 80 t/h of bulk material at 1,400 kg/m³, 5 m horizontal, belt speed 1 m/s on 35° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 80 / (3.6 × 1 × 1,400) = 0.01587 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.01587 / 0.197) = 283.9 mm → next standard width 300 mm; A = K · B² = 0.197 × 0.3² = 0.01773 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 1 × 1,400 × 0.01773 = 89.4 t/h (margin 11.7 %) → 80.0 vs limit 89.4 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 80 / (3.6 × 1) = 22.222 kg/m (design capacity); qB = B × 15 = 0.3 × 15 = 4.50 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 5 × 9.81 × [4.250 + 1.233 + (2 × 4.50 + 22.222) × 1.00000] = 36.0 N |
| Secondary resistance | C(5 m) = 4.5000 (DIN 22101 Table 5) (under 80 m: approximate, itemise on short conveyors); FN = (C − 1) · FH = (4.5000 − 1) × 36.0 = 126.0 N |
| Lift resistance | FSt = 0 N (horizontal) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (36.0 + 126.0 + 0.0) = 162.0 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 4.5000 × 0.02 × 5 × 9.81 × 14.483 = 63.9 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 162.0 × 1 / 1000 = 0.162 kW; empty 63.9 × 1 / 1000 = 0.064 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 0.162 × 1.3 / 0.8935 = 0.236 kW; empty: motoring 0.064 × 1.3 / 0.8935 = 0.093 kW; the loaded belt governs: Pmotor = 0.236 kW |
| Motor rating | Next standard IEC rating ≥ 0.236 kW → 0.75 kW (31.4 % loaded) → 0.236 vs limit 0.750 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 162.0 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 162.0 / (3.0028 − 1) = 80.9 N; T1 = T2 + Te,d = 242.9 N (0.8 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 162.0 × 0.5/2 = 40.5 N·m; ndrum = 60 · v / (π · D) = 60 × 1 / (π × 0.5) = 38.20 rpm; i = nmotor / ndrum = 1,450 / 38.20 = 37.961 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 5) = 0.150 m; Ftake-up = 1.5 × T2 = 1.5 × 80.9 = 121.4 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 300 mm belt, Te 162.0 N loaded, 0.75 kW motor (loaded belt governs); governing: belt capacity. Conveyor shorter than 80 m: secondary resistances (C = 4.50) are approximate here. ISO 5048 / DIN 22101 ask for the feed acceleration, skirt, pulley and belt-bending resistances to be itemised on short conveyors. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 80/(3.6 × 1 × 1400) = 0.01587 m²; B = √(0.01587/0.197) = 283.9 mm → 300 mm standard; A = 0.197 × 0.3² = 0.01773 m² → Q_max = 89.4 t/h; q_G = 80/(3.6 × 1) = 22.222 kg/m; q_B = 4.50 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(5 m) = 4.5000 (DIN 22101 Table 5; under 80 m Rulmeca Cq); cos δ = 1.00000; LOADED F_H = 0.02 × 5 × 9.81 × 36.706 = 36.0 N, F_N = (4.5000 − 1) × 36.0 = 126.0 N, F_St = 22.222 × 9.81 × 0.000 = 0.0 N, T_e = (36.0 + 126.0 + 0.0 + 0) = 162.0 N (motoring: |P_drum| = 0.162 kW, P_motor = 0.162 × 1.3 / 0.8935 = 0.236 kW); EMPTY T_e = 4.5000 × 0.02 × 5 × 9.81 × 14.483 + 0 = 63.9 N (motoring: |P_drum| = 0.064 kW, P_motor = 0.064 × 1.3 / 0.8935 = 0.093 kW); governing loaded → 0.236 kW → 0.75 kW standard (31.4 %); regenerative power at the motor = 0.000 kW; design |T_e| = 162.0 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 162.0/(3.0028 − 1) = 80.9 N; T1 = 242.9 N; M_drum = 162.0 × 0.5/2 = 40.5 N·m; n_drum = 60 × 1/(π × 0.5) = 38.20 rpm; i = 1450/38.20 = 37.961; take-up = max(0.15, 0.025 × 5) = 0.150 m, force 1.5 × 80.9 = 121.4 N (validation case c0026-short-5m-takeup-floor) |
Example 20 — Slow 0.5 m/s belt for dense ore
The slowest belt speed the engine accepts with a 3200 kg/m³ material: a wide belt and a speed warning.
Given: 400 t/h of magnetite at 3,200 kg/m³, 40 m horizontal, belt speed 0.5 m/s on 35° idlers; belt width to be selected, belt mass estimated. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 400 / (3.6 × 0.5 × 3,200) = 0.06944 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.06944 / 0.197) = 593.7 mm → next standard width 650 mm; A = K · B² = 0.197 × 0.65² = 0.08323 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 0.5 × 3,200 × 0.08323 = 479.4 t/h (margin 19.9 %) → 400.0 vs limit 479.4 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 400 / (3.6 × 0.5) = 222.222 kg/m (design capacity); qB = B × 15 = 0.65 × 15 = 9.75 kg/m (estimated); qRO = 7.583, qRU = 2.167 kg/m (typical 650 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 40 × 9.81 × [7.583 + 2.167 + (2 × 9.75 + 222.222) × 1.00000] = 1,973.6 N |
| Secondary resistance | C(40 m) = 2.2000 (DIN 22101 Table 5) (under 80 m: approximate, itemise on short conveyors); FN = (C − 1) · FH = (2.2000 − 1) × 1,973.6 = 2,368.3 N |
| Lift resistance | FSt = 0 N (horizontal) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (1,973.6 + 2,368.3 + 0.0) = 4,341.8 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 2.2000 × 0.02 × 40 × 9.81 × 29.250 = 505.0 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 4,341.8 × 0.5 / 1000 = 2.171 kW; empty 505.0 × 0.5 / 1000 = 0.253 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 2.171 × 1.3 / 0.8935 = 3.159 kW; empty: motoring 0.253 × 1.3 / 0.8935 = 0.367 kW; the loaded belt governs: Pmotor = 3.159 kW |
| Motor rating | Next standard IEC rating ≥ 3.159 kW → 4 kW (79.0 % loaded) → 3.159 vs limit 4.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 4,341.8 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 4,341.8 / (3.0028 − 1) = 2,167.8 N; T1 = T2 + Te,d = 6,509.7 N (10.0 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 4,341.8 × 0.5/2 = 1,085.5 N·m; ndrum = 60 · v / (π · D) = 60 × 0.5 / (π × 0.5) = 19.10 rpm; i = nmotor / ndrum = 1,450 / 19.10 = 75.922 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 40) = 1.000 m; Ftake-up = 1.5 × T2 = 1.5 × 2,167.8 = 3,251.8 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 650 mm belt, Te 4,341.8 N loaded, 4 kW motor (loaded belt governs); governing: belt capacity. Belt speed is low (<1 m/s). May cause material spillage. Conveyor shorter than 80 m: secondary resistances (C = 2.20) are approximate here. ISO 5048 / DIN 22101 ask for the feed acceleration, skirt, pulley and belt-bending resistances to be itemised on short conveyors. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 400/(3.6 × 0.5 × 3200) = 0.06944 m²; B = √(0.06944/0.197) = 593.7 mm → 650 mm standard; A = 0.197 × 0.65² = 0.08323 m² → Q_max = 479.4 t/h; q_G = 400/(3.6 × 0.5) = 222.222 kg/m; q_B = 9.75 kg/m (15 × B); q_RO = 7.583, q_RU = 2.167 kg/m (Rulmeca Tab. 11 650 mm sets / 1.2 m and 3.0 m pitch unless given); C(40 m) = 2.2000 (DIN 22101 Table 5; under 80 m Rulmeca Cq); cos δ = 1.00000; LOADED F_H = 0.02 × 40 × 9.81 × 251.472 = 1973.6 N, F_N = (2.2000 − 1) × 1973.6 = 2368.3 N, F_St = 222.222 × 9.81 × 0.000 = 0.0 N, T_e = (1973.6 + 2368.3 + 0.0 + 0) = 4341.8 N (motoring: |P_drum| = 2.171 kW, P_motor = 2.171 × 1.3 / 0.8935 = 3.159 kW); EMPTY T_e = 2.2000 × 0.02 × 40 × 9.81 × 29.250 + 0 = 505.0 N (motoring: |P_drum| = 0.253 kW, P_motor = 0.253 × 1.3 / 0.8935 = 0.367 kW); governing loaded → 3.159 kW → 4 kW standard (79.0 %); regenerative power at the motor = 0.000 kW; design |T_e| = 4341.8 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 4341.8/(3.0028 − 1) = 2167.8 N; T1 = 6509.7 N; M_drum = 4341.8 × 0.5/2 = 1085.5 N·m; n_drum = 60 × 0.5/(π × 0.5) = 19.10 rpm; i = 1450/19.10 = 75.922; take-up = max(0.15, 0.025 × 40) = 1.000 m, force 1.5 × 2167.8 = 3251.8 N (validation case c0026-slow-belt-dense-ore) |
Example 21 — Steep 12° decline, regenerative when loaded
The loaded belt overhauls the drive: the motor is sized on the regenerative power |P| × SF × η and the drive must absorb braking energy (regenerative VFD or braking resistor plus a fail-safe brake).
Given: 600 t/h of crushed copper ore at 1,600 kg/m³, 300 m decline 12°, belt speed 2.5 m/s on 35° idlers; belt width to be selected, belt mass 12 kg/m given. Friction factor f = 0.02, special resistances FS 2,000 N. Drive: 0.8 m pulley, wrap 210°, μ = 0.35, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 600 / (3.6 × 2.5 × 1,600) = 0.04167 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = √(Areq / K) = √(0.04167 / 0.197) = 459.9 mm → next standard width 500 mm; A = K · B² = 0.197 × 0.5² = 0.04925 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2.5 × 1,600 × 0.04925 = 709.2 t/h (margin 18.2 %) → 600.0 vs limit 709.2 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 600 / (3.6 × 2.5) = 66.667 kg/m (design capacity); qB = 12.00 kg/m (given); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 300 × 9.81 × [4.250 + 1.233 + (2 × 12.00 + 66.667) × 0.97815] = 5,542.8 N |
| Secondary resistance | C(300 m) = 1.3100 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.3100 − 1) × 5,542.8 = 1,718.3 N |
| Lift resistance | FSt = qG · g · H, H = L · sin δ = 300 × sin(−12°) = −62.374 m: 66.667 × 9.81 × −62.374 = −40,792.3 N (material only — the belt cancels between the strands); downhill: the material helps drive the belt |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (5,542.8 + 1,718.3 − 40,792.3 + 2,000) = −31,531.2 N (regenerative) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.3100 × 0.02 × 300 × 9.81 × 28.959 + 2,000 = 4,232.9 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded −31,531.2 × 2.5 / 1000 = −78.828 kW; empty 4,232.9 × 2.5 / 1000 = 10.582 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: regenerative 78.828 × 1.3 × 0.8935 = 91.560 kW; empty: motoring 10.582 × 1.3 / 0.8935 = 15.397 kW; the loaded belt governs: Pmotor = 91.560 kW |
| Regenerative braking | Power fed back through the motor Pregen = |Pdrum| × η = 70.431 kW: Absorb 70.4 kW: regenerative (active front end) VFD or braking resistor, plus a fail-safe mechanical brake sized for the loaded decline |
| Motor rating | Next standard IEC rating ≥ 91.560 kW → 110 kW (83.2 % loaded) → 91.560 vs limit 110.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 31,531.2 N (loaded); eμθ = e0.35 × 210π/180 = 3.6068; T2 = Te,d / (eμθ − 1) = 31,531.2 / (3.6068 − 1) = 12,095.8 N; T1 = T2 + Te,d = 43,627.1 N (87.3 N/mm of width); regenerative: the tight strand is the one leaving the drive pulley |
| Drum and gearbox | Mdrum = Te,d × D/2 = 31,531.2 × 0.8/2 = 12,612.5 N·m; ndrum = 60 · v / (π · D) = 60 × 2.5 / (π × 0.8) = 59.68 rpm; i = nmotor / ndrum = 1,450 / 59.68 = 24.295 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 300) = 7.500 m; Ftake-up = 1.5 × T2 = 1.5 × 12,095.8 = 18,143.7 N; Constant-tension take-up (L ≥ 200 m) |
| Result | 2/2 checks pass → PASS; 500 mm belt, Te −31,531.2 N loaded, 110 kW motor (loaded belt governs, regenerative — braking required); governing: belt capacity. Regenerative conveyor: the loaded belt overhauls the drive (T_e loaded -31531 N, empty 4233 N). The drive must absorb about 70.4 kW at the motor terminals: use a regenerative (active front end) VFD or a braking resistor, plus a fail-safe mechanical brake sized for the loaded decline (the belt runs away on loss of power). Regenerative power is maximised by LOW running resistance: re-check with the lower-bound friction factor (DIN 22101 suggests f ≈ 0.012–0.016 for braked downhill conveyors; f = 0.02 used here). Drive changes mode with load: regenerative loaded (-78.83 kW at the drum), motoring empty (10.58 kW). The drive must control torque in both directions. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 600/(3.6 × 2.5 × 1600) = 0.04167 m²; B = √(0.04167/0.197) = 459.9 mm → 500 mm standard; A = 0.197 × 0.5² = 0.04925 m² → Q_max = 709.2 t/h; q_G = 600/(3.6 × 2.5) = 66.667 kg/m; q_B = 12.00 kg/m (given); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(300 m) = 1.3100 (DIN 22101 Table 5); cos δ = 0.97815; LOADED F_H = 0.02 × 300 × 9.81 × 94.169 = 5542.8 N, F_N = (1.3100 − 1) × 5542.8 = 1718.3 N, F_St = 66.667 × 9.81 × −62.374 = −40792.3 N, T_e = (5542.8 + 1718.3 − 40792.3 + 2000) = −31531.2 N (regenerative: |P_drum| = 78.828 kW, P_motor = 78.828 × 1.3 × 0.8935 = 91.560 kW); EMPTY T_e = 1.3100 × 0.02 × 300 × 9.81 × 28.959 + 2000 = 4232.9 N (motoring: |P_drum| = 10.582 kW, P_motor = 10.582 × 1.3 / 0.8935 = 15.397 kW); governing loaded → 91.560 kW → 110 kW standard (83.2 %); regenerative power at the motor = 70.431 kW; design |T_e| = 31531.2 N (loaded); e^(μθ) = e^(0.35 × 210π/180) = 3.6068; T2 = 31531.2/(3.6068 − 1) = 12095.8 N; T1 = 43627.1 N; M_drum = 31531.2 × 0.8/2 = 12612.5 N·m; n_drum = 60 × 2.5/(π × 0.8) = 59.68 rpm; i = 1450/59.68 = 24.295; take-up = max(0.15, 0.025 × 300) = 7.500 m, force 1.5 × 12095.8 = 18143.7 N (validation case c0026-steep-decline-regenerative) |
Example 22 — Given 500 mm belt cannot carry 650 t/h
The belt-capacity check fails when the user-specified width is below what the capacity needs.
Given: 650 t/h of bulk material at 1,600 kg/m³, 100 m horizontal, belt speed 2 m/s on 35° idlers; belt width 500 mm given, belt mass estimated. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 650 / (3.6 × 2 × 1,600) = 0.05642 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = 500 mm (given); A = K · B² = 0.197 × 0.5² = 0.04925 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2 × 1,600 × 0.04925 = 567.4 t/h (margin -12.7 %) → 650.0 vs limit 567.4 t/h FAIL |
| Linear masses | qG = Q / (3.6 · v) = 650 / (3.6 × 2) = 90.278 kg/m (design capacity); qB = B × 15 = 0.5 × 15 = 7.50 kg/m (estimated); qRO = 4.250, qRU = 1.233 kg/m (typical 500 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 100 × 9.81 × [4.250 + 1.233 + (2 × 7.50 + 90.278) × 1.00000] = 2,173.1 N |
| Secondary resistance | C(100 m) = 1.7800 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.7800 − 1) × 2,173.1 = 1,695.0 N |
| Lift resistance | FSt = 0 N (horizontal) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (2,173.1 + 1,695.0 + 0.0) = 3,868.2 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.7800 × 0.02 × 100 × 9.81 × 20.483 = 715.4 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 3,868.2 × 2 / 1000 = 7.736 kW; empty 715.4 × 2 / 1000 = 1.431 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 7.736 × 1.3 / 0.8935 = 11.256 kW; empty: motoring 1.431 × 1.3 / 0.8935 = 2.082 kW; the loaded belt governs: Pmotor = 11.256 kW |
| Motor rating | Next standard IEC rating ≥ 11.256 kW → 15 kW (75.0 % loaded) → 11.256 vs limit 15.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 3,868.2 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 3,868.2 / (3.0028 − 1) = 1,931.3 N; T1 = T2 + Te,d = 5,799.5 N (11.6 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 3,868.2 × 0.5/2 = 967.0 N·m; ndrum = 60 · v / (π · D) = 60 × 2 / (π × 0.5) = 76.39 rpm; i = nmotor / ndrum = 1,450 / 76.39 = 18.980 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 100) = 2.500 m; Ftake-up = 1.5 × T2 = 1.5 × 1,931.3 = 2,897.0 N; Gravity take-up (L < 200 m) |
| Result | 1/2 checks pass → FAIL; 500 mm belt, Te 3,868.2 N loaded, 15 kW motor (loaded belt governs); governing: belt capacity. Capacity margin is low (-12.7%). Consider wider belt for surge capacity. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 650/(3.6 × 2 × 1600) = 0.05642 m²; B = 500 mm given; A = 0.197 × 0.5² = 0.04925 m² → Q_max = 567.4 t/h; q_G = 650/(3.6 × 2) = 90.278 kg/m; q_B = 7.50 kg/m (15 × B); q_RO = 4.250, q_RU = 1.233 kg/m (Rulmeca Tab. 11 500 mm sets / 1.2 m and 3.0 m pitch unless given); C(100 m) = 1.7800 (DIN 22101 Table 5); cos δ = 1.00000; LOADED F_H = 0.02 × 100 × 9.81 × 110.761 = 2173.1 N, F_N = (1.7800 − 1) × 2173.1 = 1695.0 N, F_St = 90.278 × 9.81 × 0.000 = 0.0 N, T_e = (2173.1 + 1695.0 + 0.0 + 0) = 3868.2 N (motoring: |P_drum| = 7.736 kW, P_motor = 7.736 × 1.3 / 0.8935 = 11.256 kW); EMPTY T_e = 1.7800 × 0.02 × 100 × 9.81 × 20.483 + 0 = 715.4 N (motoring: |P_drum| = 1.431 kW, P_motor = 1.431 × 1.3 / 0.8935 = 2.082 kW); governing loaded → 11.256 kW → 15 kW standard (75.0 %); regenerative power at the motor = 0.000 kW; design |T_e| = 3868.2 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 3868.2/(3.0028 − 1) = 1931.3 N; T1 = 5799.5 N; M_drum = 3868.2 × 0.5/2 = 967.0 N·m; n_drum = 60 × 2/(π × 0.5) = 76.39 rpm; i = 1450/76.39 = 18.980; take-up = max(0.15, 0.025 × 100) = 2.500 m, force 1.5 × 1931.3 = 2897.0 N (validation case c0026-width-given-capacity-fail) |
Example 23 — Oversized 1200 mm belt for 300 t/h
A wide belt chosen for lump size: large capacity margin, while the material load and drive power follow the design capacity Q/(3.6·v), not the belt size.
Given: 300 t/h of run-of-mine rock at 1,600 kg/m³, 90 m horizontal, belt speed 2 m/s on 35° idlers; belt width 1,200 mm given, belt mass 22 kg/m given. Friction factor f = 0.02. Drive: 0.5 m pulley, wrap 210°, μ = 0.3, motor 1,450 rpm, service factor 1.3, efficiencies gearbox 0.95 / coupling 0.99 / motor 0.95.
| Cross-section | Areq = Q / (3.6 · v · ρ) = 300 / (3.6 × 2 × 1,600) = 0.02604 m² |
|---|---|
| Belt width | K(35°) = 0.197; B = 1,200 mm (given); A = K · B² = 0.197 × 1.2² = 0.28368 m² |
| Capacity check | Qmax = 3.6 · v · ρ · A = 3.6 × 2 × 1,600 × 0.28368 = 3,268.0 t/h (margin 989.3 %) → 300.0 vs limit 3,268.0 t/h PASS |
| Linear masses | qG = Q / (3.6 · v) = 300 / (3.6 × 2) = 41.667 kg/m (design capacity); qB = 22.00 kg/m (given); qRO = 16.917, qRU = 5.233 kg/m (typical 1,200 mm idler sets ÷ 1.2 m carrying / 3.0 m return pitch, unless given) |
| Main resistance | FH = f · L · g · [qRO + qRU + (2qB + qG) · cos δ] = 0.02 × 90 × 9.81 × [16.917 + 5.233 + (2 × 22.00 + 41.667) × 1.00000] = 1,903.8 N |
| Secondary resistance | C(90 m) = 1.8500 (DIN 22101 Table 5); FN = (C − 1) · FH = (1.8500 − 1) × 1,903.8 = 1,618.3 N |
| Lift resistance | FSt = 0 N (horizontal) |
| Effective tension, loaded | Te = (FH + FN + FSt + FS) × kimpact = (1,903.8 + 1,618.3 + 0.0) = 3,522.1 N (motoring) |
| Effective tension, empty | Te,empty = C · f · L · g · [qRO + qRU + 2qB · cos δ] + FS = 1.8500 × 0.02 × 90 × 9.81 × 66.150 = 2,160.9 N (motoring; no material, no impact factor — part-loaded belts lie between the empty and full-load values) |
| Drum power | Pdrum = Te × v: loaded 3,522.1 × 2 / 1000 = 7.044 kW; empty 2,160.9 × 2 / 1000 = 4.322 kW |
| Motor power | η = 0.95 × 0.99 × 0.95 = 0.8935; motoring Pmotor = |Pdrum| × SF / η, regenerative Pmotor = |Pdrum| × SF × η. Loaded: motoring 7.044 × 1.3 / 0.8935 = 10.249 kW; empty: motoring 4.322 × 1.3 / 0.8935 = 6.288 kW; the loaded belt governs: Pmotor = 10.249 kW |
| Motor rating | Next standard IEC rating ≥ 10.249 kW → 11 kW (93.2 % loaded) → 10.249 vs limit 11.000 kW PASS |
| Belt tensions | Te,d = max(|Te|, |Te,empty|) = 3,522.1 N (loaded); eμθ = e0.3 × 210π/180 = 3.0028; T2 = Te,d / (eμθ − 1) = 3,522.1 / (3.0028 − 1) = 1,758.5 N; T1 = T2 + Te,d = 5,280.6 N (4.4 N/mm of width) |
| Drum and gearbox | Mdrum = Te,d × D/2 = 3,522.1 × 0.5/2 = 880.5 N·m; ndrum = 60 · v / (π · D) = 60 × 2 / (π × 0.5) = 76.39 rpm; i = nmotor / ndrum = 1,450 / 76.39 = 18.980 |
| Take-up | ΔL = max(0.15, 0.025 × L) = max(0.15, 0.025 × 90) = 2.250 m; Ftake-up = 1.5 × T2 = 1.5 × 1,758.5 = 2,637.8 N; Gravity take-up (L < 200 m) |
| Result | 2/2 checks pass → PASS; 1,200 mm belt, Te 3,522.1 N loaded, 11 kW motor (loaded belt governs); governing: motor rating. Motor loading is high (93.2%). Consider next motor size up. |
| Reference | Hand calculation (ISO 5048 / DIN 22101 coefficient-C method, CEMA 7th ed. load cases): A_req = 300/(3.6 × 2 × 1600) = 0.02604 m²; B = 1200 mm given; A = 0.197 × 1.2² = 0.28368 m² → Q_max = 3268.0 t/h; q_G = 300/(3.6 × 2) = 41.667 kg/m; q_B = 22.00 kg/m (given); q_RO = 16.917, q_RU = 5.233 kg/m (Rulmeca Tab. 11 1200 mm sets / 1.2 m and 3.0 m pitch unless given); C(90 m) = 1.8500 (DIN 22101 Table 5); cos δ = 1.00000; LOADED F_H = 0.02 × 90 × 9.81 × 107.817 = 1903.8 N, F_N = (1.8500 − 1) × 1903.8 = 1618.3 N, F_St = 41.667 × 9.81 × 0.000 = 0.0 N, T_e = (1903.8 + 1618.3 + 0.0 + 0) = 3522.1 N (motoring: |P_drum| = 7.044 kW, P_motor = 7.044 × 1.3 / 0.8935 = 10.249 kW); EMPTY T_e = 1.8500 × 0.02 × 90 × 9.81 × 66.150 + 0 = 2160.9 N (motoring: |P_drum| = 4.322 kW, P_motor = 4.322 × 1.3 / 0.8935 = 6.288 kW); governing loaded → 10.249 kW → 11 kW standard (93.2 %); regenerative power at the motor = 0.000 kW; design |T_e| = 3522.1 N (loaded); e^(μθ) = e^(0.3 × 210π/180) = 3.0028; T2 = 3522.1/(3.0028 − 1) = 1758.5 N; T1 = 5280.6 N; M_drum = 3522.1 × 0.5/2 = 880.5 N·m; n_drum = 60 × 2/(π × 0.5) = 76.39 rpm; i = 1450/76.39 = 18.980; take-up = max(0.15, 0.025 × 90) = 2.250 m, force 1.5 × 1758.5 = 2637.8 N (validation case c0026-width-given-oversized) |
Standards & References
- ISO 5048:1989 — Continuous mechanical handling equipment — Belt conveyors with carrying idlers — Calculation of operating power and tensile forces
- DIN 22101:2011 — Continuous conveyors — Belt conveyors for loose bulk materials — Basis for calculation and dimensioning
- CEMA (7th Edition) — Belt Conveyors for Bulk Materials, Conveyor Equipment Manufacturers Association
- IEC 60034-1 — Rotating electrical machines — Rating and performance (standard motor sizes)
- Eytelwein equation — Capstan equation for belt tension ratio around a drum: \(T_1 / T_2 = e^{\mu \alpha}\)
Tips & Limitations
Tips
- For inclined conveyors exceeding 18°, verify that the material angle of repose is sufficient to prevent rollback. Consider chevron-cleated or patterned belts above 18°.
- The friction factor \(f\) varies significantly with installation quality: use 0.015–0.02 for well-maintained systems and 0.025–0.03 for harsh environments.
- Belt mass is estimated at 15 kg/m per metre of belt width when not specified. For steel-cord or heavy-duty belts, always enter the actual belt mass from manufacturer data.
- A wrap angle of 210° (with snub pulley) gives a tension ratio of approximately 3:1, which is adequate for most applications. Use a higher wrap angle or dual-drive arrangement for heavily loaded conveyors.
- A service factor of 1.3 is typical for 16–24 hours/day operation. Use 1.5–1.6 for continuous 24/7 duty with high impact loading.
- Always use a VFD (variable frequency drive) for soft starting and torque limiting to protect the belt and mechanical components.
Limitations
- Steady-state only — starting torque, dynamic braking, and transient analysis are not performed. Acceleration and deceleration forces can be 1.5–3× running forces. Regenerative declines are flagged with their steady braking power, but the brake itself (stopping torque, stopping distance) is not sized.
- Single slope — the profile is one inclination; multi-slope profiles with part-loaded declining sections (often the critical regenerative case) are not modelled.
- Simplified belt mass — when belt mass is not provided, the 15 kg/m² estimate is a rough approximation. Actual belt mass depends on carcass type, cover thickness, and belt rating.
- Coefficient \(C\) method — secondary resistances are a length-dependent multiple of the main resistance (one feed point). Conveyors under 80 m, multiple feed points or long skirtboards need them itemised; enter the extra as special resistance.
- Estimated idler masses — when \(q_{RO}\)/\(q_{RU}\) are not given, typical idler sets are assumed; enter the selected idlers' rotating mass and pitch.
- Single-drive configuration — dual-drive (head + tail) and booster-drive configurations are not modelled.
- Troughing factors are approximations — the \(K(\theta)\) values assume a standard 3-roll troughing idler set with equal-length rolls. Manufacturer-specific data should be used for detailed design.
- Take-up calculation is simplified — uses 2% thermal + 0.5% elastic elongation. Actual elongation depends on belt modulus and operating conditions.
Developer Guide
Architecture
File layout:
components/c0026_conveyor_design/component.py— Component registration, parameter schema (CONVEYOR_DESIGN_SCHEMA), SVG diagram generatorcomponents/c0026_conveyor_design/calculations.py— Core calculation engine (ConveyorDesignCalculatorclass), no Django dependenciescomponents/c0026_conveyor_design/equations.py— Equation builder (build_conveyor_equations) for formatted calculation methodology displaycomponents/c0026_conveyor_design/excel_generator.py— Excel export supportcomponents/c0026_conveyor_design/templates/— Sidebar form template
The calculator class is ConveyorDesignCalculator.
It follows the standard calc-engine pattern: accepts a parameters dict
in the constructor, runs a multi-step calculate() method,
and returns a results dict.
Key data structures:
STANDARD_BELT_WIDTHS— list of 13 standard belt widths (300–2400 mm)STANDARD_MOTOR_SIZES— list of 34 IEC motor ratings (0.75–1000 kW)TROUGHING_FACTORS— dict mapping troughing angle to \(K(\theta)\) coefficient
Code Paths
Key methods in ConveyorDesignCalculator:
| Function | Purpose |
|---|---|
_extract_parameters() |
Extract and set all input parameters with defaults |
_calculate_cross_section() |
Required belt cross-sectional area from capacity |
_select_belt_width() |
Auto-select or validate belt width; compute actual area and capacity |
_calculate_linear_masses() |
Material load at the design capacity, belt and idler rotating masses |
_calculate_resistances() |
ISO 5048 main resistance, coefficient \(C\) secondary resistances and lift, loaded and empty |
_calculate_total_force() |
Loaded (with impact factor) and empty-belt traction force; design force = largest magnitude |
_calculate_drive_power() |
Drum power and motor requirement per load case (motoring ÷η, regenerative ×η); governing case and regenerative braking power |
_select_motor_and_gearbox() |
Round to standard motor size |
_calculate_tensions() |
Eytelwein equation for T1 and T2 |
_calculate_drum_parameters() |
Drum torque, drum speed, gearbox ratio |
_calculate_take_up() |
Take-up travel and counterweight force |
_generate_warnings() |
Capacity margin, motor loading, tension, and inclination warnings |
Supporting modules:
| Function | Purpose |
|---|---|
build_conveyor_equations(results) |
Generate formatted HTML with LaTeX equations for the methodology display |
generate_conveyor_diagram_svg(params, results) |
Generate SVG conveyor profile diagram with pulleys, tension arrows, and info box |
Testing
Running tests:
pytest calcs/components/c0026_conveyor_design/ -v
pytest calcs/test_c0026* -v
pytest -m validation mcp_public/tests/test_validation_corpus.py -k c0026 -q
Worked examples: the examples above are generated from the
validation corpus in mcp_public/validation/cases/fe_calc_conveyor/
by python manage.py generate_help_examples --tool fe_calc_conveyor
(renderer calcs/core/help_examples/conveyor.py). Add a case there
rather than editing the fragment by hand.
How to extend:
- Add new troughing angles by extending the
TROUGHING_FACTORSdict and thetroughing_angleenum in the schema. - Itemise secondary resistances (feed acceleration, skirtboards, pulleys) for short
conveyors by replacing the \(C\) term in
_calculate_resistances(). - For dual-drive configurations, modify
_calculate_tensions()to split traction force between head and tail drives with separate wrap angles. - Add belt rating verification by comparing
tension_per_mm_width_nagainst manufacturer allowable working tension tables. - Write tests covering new parameters and edge cases (zero inclination, maximum belt width, minimum capacity).